KITOZER 24-channel battery voltage tester is a centralized monitoring device that continuously tracks terminal voltage, temperature, and charge-discharge current on a string of up to 24 valve-regulated lead-acid or lithium batteries used in UPS and DC power systems. The main unit mounts in the battery room cabinet and connects to each cell via a tap cable, reporting every reading to the BMS or DCIM platform over Modbus RS485 or Ethernet. Early detection of a weak cell prevents sudden battery string failure during a utility outage, which is the leading cause of double-conversion UPS downtime during prolonged mains loss. The tester also records charge and discharge curves, supporting battery health trending over years of operation.

Technical Specifications

24 cell voltage channels, measurement range 0V to 3V per cell or 0V to 12V per block, accuracy plus or minus 5mV. Temperature channels 6, range minus 40C to plus 125C. String current sensor via hall sensor 0A to 300A. Main unit display 4.3 inch color. RS485 Modbus RTU and Ethernet Modbus TCP. Alarm relay outputs 4. Power supply 85V to 265VAC. Operating temperature 0C to plus 50C. DIN rail or wall mount. CE, KITOZER brand, three year warranty.

Application Scenarios

This tester is installed in data center battery rooms, telecom base station shelters, substation DC panels, and industrial control power supplies where VRLA or lithium battery strings support UPS, diesel engine start, or relay protection. It is also used in solar off-grid and hybrid power plants where long battery autonomy is essential. The 24-channel configuration matches a standard 48V telecom battery string or a section of a larger UPS battery bank. For larger systems, multiple testers are paralleled on the same RS485 or Ethernet bus, each handling 24 cells.

Advantages and Features

Continuous per-cell monitoring removes the need for monthly manual voltage walks, which are both labor-intensive and miss transient weak cells. Voltage and temperature alarms trigger before a cell reaches end of life, allowing scheduled replacement. Charge-discharge curve recording supports battery health trend analysis and predicts remaining service life. The Modbus TCP integration feeds DCIM, giving operators a live view of battery state from the NOC. The tester also supports automatic equalization charge supervision, warning when a cell is not accepting equalization voltage.

Installation and Maintenance

Mount the main unit in a convenient location in the battery room. Run tap cables from each cell terminal to the channel board, keeping polarity correct. Install the hall current sensor around the battery string cable. Place temperature sensors at the warmest and coolest cells. Set cell nominal voltage, alarm thresholds, and Modbus address through the front menu. Verify readings against a digital multimeter during commissioning. Maintenance consists of annual tap-cable resistance check and visual inspection for corrosion at terminals. Replace tap cables if insulation cracks.