Table of Contents
ToggleProduct Overview
KITOZER 24-channel battery voltage tester is a centralized monitoring device that continuously tracks terminal voltage, temperature, and charge-discharge current on a string of up to 24 valve-regulated lead-acid or lithium batteries used in UPS and DC power systems. The main unit mounts in the battery room cabinet and connects to each cell via a tap cable, reporting every reading to the BMS or DCIM platform over Modbus RS485 or Ethernet. Early detection of a weak cell prevents sudden battery string failure during a utility outage, which is the leading cause of double-conversion UPS downtime during prolonged mains loss. The tester also records charge and discharge curves, supporting battery health trending over years of operation.
Without continuous monitoring, the only way to detect a weak cell is a monthly manual walk with a voltmeter, which is labor-intensive and misses transient weaknesses that appear only during discharge. The KITOZER tester watches every cell 24 hours a day, alarming when a cell voltage drifts outside the programmable window during float, charge, or discharge. Temperature sensors detect overheating cells, which are a leading indicator of internal short or thermal runaway. The stored discharge curves also support capacity test planning, so engineers know when to schedule a full load test.
Technical Specifications
24 cell voltage channels, measurement range 0V to 3V per cell or 0V to 12V per block, accuracy plus or minus 5mV. Temperature channels 6, range minus 40C to plus 125C. String current sensor via hall sensor 0A to 300A. Main unit display 4.3 inch color. RS485 Modbus RTU and Ethernet Modbus TCP. Alarm relay outputs 4. Power supply 85V to 265VAC. Operating temperature 0C to plus 50C. DIN rail or wall mount. CE, KITOZER brand, three year warranty.
Application Scenarios
This tester is installed in data center battery rooms, telecom base station shelters, substation DC panels, and industrial control power supplies where VRLA or lithium battery strings support UPS, diesel engine start, or relay protection. It is also used in solar off-grid and hybrid power plants where long battery autonomy is essential. The 24-channel configuration matches a standard 48V telecom battery string or a section of a larger UPS battery bank. For larger systems, multiple testers are paralleled on the same RS485 or Ethernet bus, each handling 24 cells.
Additional installations include hospital emergency power systems, railway signaling batteries, and offshore wind turbine control power. In each case, the battery is the last line of defense when the mains fails, so its health must be known continuously. The Modbus TCP integration feeds the DCIM, giving NOC operators a live view of every cell voltage and temperature. Alarm emails are sent when a cell drifts, allowing scheduled replacement before the next utility outage.
Advantages and Features
Continuous per-cell monitoring removes the need for monthly manual voltage walks, which are both labor-intensive and miss transient weak cells. Voltage and temperature alarms trigger before a cell reaches end of life, allowing scheduled replacement. Charge-discharge curve recording supports battery health trend analysis and predicts remaining service life. The Modbus TCP integration feeds DCIM, giving operators a live view of battery state from the NOC. The tester also supports automatic equalization charge supervision, warning when a cell is not accepting equalization voltage.
The 5mV accuracy is sufficient to detect early cell imbalance in VRLA batteries. The hall current sensor measures both charge and discharge current, supporting Coulomb counting for state-of-health estimation. The alarm relays trigger local annunciation and BMS alarms. The touchscreen shows cell bar graphs, so a weak cell stands out visually. The unit supports up to 32 testers on one RS485 bus, covering a 768-cell battery plant.
Installation and Maintenance
Mount the main unit in a convenient location in the battery room. Run tap cables from each cell terminal to the channel board, keeping polarity correct. Install the hall current sensor around the battery string cable. Place temperature sensors at the warmest and coolest cells. Set cell nominal voltage, alarm thresholds, and Modbus address through the front menu. Verify readings against a digital multimeter during commissioning. Maintenance consists of annual tap-cable resistance check and visual inspection for corrosion at terminals. Replace tap cables if insulation cracks.
During installation, keep tap cables away from power cables to avoid noise. Ground the shield of the hall sensor cable at one end. Set the low-voltage alarm threshold at 1.8V per cell for VRLA, and the high-temperature alarm at 45C. Test the alarms by temporarily disconnecting one tap cable. The battery room temperature should be kept at 20C to 25C for maximum battery life. Annual capacity discharge tests should be scheduled based on the trend data from the tester.
Price
From $380/pc. Contact +86 13922289957 for battery tester pricing.