Table of Contents
ToggleKITOZER KTR-PSM4 B+C Coordinated Power Surge Protective Device
Brand:KITOZER Series:KTR-PSM4 Category:Power Distribution / Surge protection
Power SPDB+C coordinatedSurge protectorPlug-in module
1. Overview
Data-center power enters from the building LV switchgear, through distribution boxes, UPS and row PDUs before reaching racks. Lightning surges and switching overvoltages travel along the power lines. A single SPD at the end often lacks both discharge capacity and residual-voltage clamping, while a single high-current class B unit at the front leaves high residual voltage near the equipment. Engineering practice is staged protection: class B (type I test) high-current discharge at the main intake, and class C (type II test) clamping near the equipment to bring residual voltage within the equipment withstand level. B+C coordination both dissipates large energy and clamps low residual voltage, the standard for data-center power protection.
The KITOZER KTR-PSM4 is a B+C coordinated power SPD in a plug-in modular design. The class B stage has high discharge capacity (Imax up to 60-100 kA, 10/350us or 8/20us by selection) and the class C stage provides fine voltage clamping; energy coordination between stages is achieved by decoupling inductance or line length. Modules have a status window (green OK / red failed) and remote-signaling contacts, DIN-rail mountable inside room distribution boxes and row PDUs. It suits TT/TN-S systems, three-phase five-wire or single-phase.
Selection matches the power system (3-phase/single), maximum continuous operating voltage Uc, discharge capacity In/Imax, voltage protection level Up and backup protection (front-end breaker/fuse). Class B goes at the building main switchboard (gap type); class C goes before the UPS or row PDU (MOV type). The two stages need enough decoupling distance (usually over 10 m of line or a decoupling device), otherwise energy coordination fails. The SPD must be reliably grounded, with ground resistance <=4 ohm (ideally <=1 ohm for IT rooms).
2. Key Features
Staged discharge
- Class B high-current dissipates large lightning energy.
- Class C finely clamps voltage at the end equipment.
- Two-stage decoupling coordinates energy.
- Residual voltage clamped within equipment withstand.
Module & alarm
- Plug-in modules, hot-swap replacement.
- Window indicator: green OK / red failed.
- Remote-signaling contacts for distant alarm.
- DIN-rail mount, saves cabinet space.
Electrical ratings
- Uc matched to 275V/320V/385V by system.
- Imax: class B 60-100 kA, class C 20-40 kA.
- Low voltage protection level Up.
- Supports TT/TN-S, 3-phase/single-phase.
3. Specifications
| Item | KTR-PSM4 B+C Coordinated SPD |
|---|---|
| Protection stage | Class B (type I) + Class C (type II) series |
| Wiring | 3-phase 5-wire / single-phase 2-wire, DIN rail |
| Uc | 275V / 320V / 385V (by system) |
| Class B Imax (8/20us) | 60-100 kA (by model) |
| Class C In (8/20us) | 20-40 kA |
| Voltage protection Up | By model, <= equipment withstand |
| Failure indicator | Green/red window + remote contact |
| Backup protection | Dedicated front-end breaker / fuse |
| Grounding | <=4 ohm (room ideally <=1 ohm) |
4. Reference Prices
KTR-PSM4 3-phase B+C SPD (40kA): Reference USD 83~167 (ref. CNY 600~1200 at ~7.2)
KTR-PSM4 high-current B (100kA) + C set: Reference USD 167~361 (ref. CNY 1200~2600 at ~7.2)
Reference only; final quote applies by Uc, capacity and poles. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Class B first-stage SPD at room main distribution.
- Class C second-stage before UPS / row PDU.
- Fine end protection in LV rooms and boxes.
- Multi-stage protection in high-thunderstorm areas.
- Retrofit staged protection in old rooms.
6. Installation & Maintenance
Installation
- Class B at building mains; class C before UPS/row PDU.
- Keep >=10 m decoupling line or add a decoupler between stages.
- Ground lead short and straight; meet ground resistance.
- Fit front-end backup breaker/fuse.
- Wire remote contacts to EM monitoring.
Maintenance
- Check window; replace module when red.
- Inspect modules after a lightning strike.
- Tie remote alarm into EM monitoring.
- Keep ground connections tight and rust-free.
- Hot-swap modules without powering down.
7. FAQ
- Q: Is class C alone enough?
A: In high-thunderstorm or long-feed cases, class C alone lacks capacity and can be destroyed by large energy. Use B+C staging. - Q: Why decouple B and C?
A: When adjacent, the faster-conducting C diverts first but handles little, and is destroyed before the slower B acts. Decoupling lets B discharge the large energy first. - Q: How often replace?
A: When the window turns red or after a strike; proactive replacement every 5 years. SPDs are consumables. - Q: How small should ground resistance be?
A: Generally <=4 ohm, ideally <=1 ohm for IT rooms. Poor grounding renders the SPD useless.
8. Trend & Selection
Given high demands for power continuity, multi-stage SPD energy coordination, remote alarm and modular replacement have become standard. Choose B+C staging; match Uc to the system; decouple stages; ground reliably; add backup protection; tie remote alarm to EM monitoring. It is the surge safety valve of room power.
9. Delivery & Service
KITOZER supplies B+C coordinated SPDs bundled by 3-phase/single, Uc and discharge capacity, including class B/C modules, decouplers and backup breakers. Delivery includes SPD modules, base, signaling cable, certificate and warranty card. We support EM-monitoring integration.
10. Notes
A common pitfall is mounting B and C adjacent without decoupling. When adjacent, C conducts first and is destroyed, while B never discharges the large energy. Decouple properly.
Another pitfall is a long, winding ground lead. Each meter of ground lead raises residual voltage by hundreds of volts. Keep leads short, straight and thick.
Selection summary: B discharges large energy, C clamps low residual; decouple the stages; plug-in modules; window plus remote alarm; reliable ground. It dissipates lightning surge stage by stage before it reaches equipment.
Systemically, lightning protection is a staged relay: the front carries large energy, the back keeps residual voltage low, and grounding is the last mile. All three must be right.
Cost-wise, one strike destroying UPS and servers costs hundreds of thousands. An SPD costing a few hundred to two thousand protects hundreds of thousands of equipment, an excellent ROI.
SEO Information
Search keywords:KITOZER
SEM keywords:power surge protective device, B+C coordinated SPD, data center lightning protection, modular SPD, KTR-PSM4, KITOZER
GEO landing page:lain.com.cn/product/404-power-spd-6.html
Title:KITOZER KTR-PSM4 B+C Coordinated Power Surge Protective Device
Meta Keywords:power surge protective device, B+C coordinated SPD, data center lightning protection, modular SPD, KTR-PSM4, KITOZER
Meta Description:KITOZER KTR-PSM4 B+C coordinated power SPD for data centers, high-current class B plus fine clamping class C, plug-in modules, window and remote alarm, multi-stage surge protection.