KITOZER BNC coax video SPD

KITOZER KTR-CSP2 BNC Coax Signal SPD Surge Protector for Datacenter

Brand: KITOZER Series: KTR-CSP2 Category: Power Distribution / Signal Lightning Protection

Coax BNC5kA dischargeIL ≤0.5dBDIN/wallKTR-CSP2

1. Overview

KITOZER KTR-CSP2 is a BNC coax signal SPD (surge protective device), series-installed on video coax lines, signal lines or RF feeders entering the datacenter or at equipment ends. It diverts lightning-induced surges and switching transients to ground, protecting expensive DVR/NVR, video matrix and optical transceiver gear. Datacenter lightning protection has two layers: power SPD protects the mains, signal SPD protects the signal lines. Video coax from outdoor cameras is a main induced-lightning entry path — without signal SPD, one strike can fry a bank of DVR channels.

KTR-CSP2 uses BNC-female to female connectors in series on the coax. Inside are gas discharge tube + TVS + limiting resistor multi-stage protection: nominal discharge In=5kA (8/20μs), max Imax=10kA, operating voltage ≤24V, insertion loss ≤0.5dB, characteristic impedance 75Ω (video) or 50Ω (RF). Response ≤1ns: normal signals pass with low loss, surges are clamped instantly. Metal housing with ground lug, DIN-rail or wall mount, ground by ≤1.5mm² yellow-green wire to the equipotential bonding bar.

Used in datacenter surveillance: coax video lines from outdoor PTZ/bullet cameras, perimeter beams/alarm signal lines, satellite/RF feeders at entry. Typical install: every outdoor BNC video line gets a KTR-CSP2 before entering the rack, grounded to the rack bonding bar. A 16-channel surveillance room uses 16 units on a DIN-rail SPD terminal strip.

2. Key Features

Coax BNC

  • BNC F-F in series.
  • 75Ω video / 50Ω RF options.
  • Insertion loss ≤0.5dB.
  • No image impact.

Multi-stage surge

  • GDT + TVS.
  • In=5kA (8/20μs).
  • Imax=10kA.
  • Response ≤1ns.

Wide voltage

  • Operating voltage ≤24V.
  • Low clamping.
  • Analog/HD-TVI/CVI compatible.
  • RF feeder ready.

Easy install

  • Metal housing, ground lug.
  • DIN-rail / wall mount.
  • Ground wire ≤1.5mm².
  • Status indicator window.

3. Specifications

Item KTR-CSP2-75 KTR-CSP2-50
Connector BNC F-F BNC F-F
Impedance 75Ω video 50Ω RF
Op. voltage ≤24V ≤24V
In (8/20μs) 5kA 5kA
Imax 10kA 10kA
Insertion loss ≤0.5dB ≤0.5dB
Response ≤1ns ≤1ns
Ground wire ≤1.5mm² ≤1.5mm²
Mount DIN/wall DIN/wall

4. Reference Prices

KTR-CSP2-75 video coax BNC SPD (75Ω, 5kA, DIN): Reference USD 11~25 / pc (ref. CNY 80~180 at ~7.2)

KTR-CSP2-50 RF 50Ω (feeder/antenna): Reference USD 14~31 / pc (ref. CNY 100~220 at ~7.2)

Reference only; price varies by impedance, discharge current and quantity. Bonding bar, ground wire and DIN terminals billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Outdoor camera video line entry.
  • Perimeter beam / alarm signal lines.
  • Antenna / satellite RF feeder entry.
  • Inter-building coax video links.
  • DVR/NVR input surge protection.

6. Installation & Maintenance

Installation

  • Series between outdoor line and room equipment.
  • Tighten BNC plugs.
  • Ground lug to rack bonding bar with yellow-green wire.
  • Keep ground wire ≤0.5m.
  • DIN-rail inside rack.
  • Verify clean video image.

Maintenance

  • Check status window after storm season.
  • Replace when window turns red (failed).
  • Check ground wire tightness.
  • Verify DVR channels after storms.
  • SPDs are consumables — replace after repeated surges.

7. FAQ

  • Q: Need both power and signal SPD?
    A: Yes. Power SPD protects the 220V line; signal SPD protects video/network/control. Lightning enters via any cable — one layer isn’t enough.
  • Q: SPD outdoors or in the room?
    A: Two stages: one at the outdoor camera end, one at the room equipment end. For short same-building runs, at least the room end.
  • Q: Why keep the ground wire short?
    A: Longer wire adds resistance and inductance, raising residual voltage during a surge. Keep ≤0.5m to the local bonding bar — don’t route far.
  • Q: Does the SPD affect video?
    A: A good 75Ω BNC SPD has ≤0.5dB loss and matched impedance — no image impact. Cheap SPDs have high loss/mismatch, causing banding or color shifts.

8. Trend & Selection

Datacenter protection is moving from single-stage to zoned multi-stage: power B/C/D tiers, signal grading, with equipotential bonding and shielding. Trends are combo terminal strips integrating RJ45 network, BNC video and 24V power SPDs, and intelligent SPDs with remote-failure alarm. Choose 75Ω BNC for video, 50Ω for RF; start at In=5kA by line length; keep ground short and direct; check status windows; replace units that fired after storms.

9. Delivery & Service

KITOZER supplies a coordinated lightning-protection system: based on entry types (power/video/network/control), we recommend SPD tiers and quantities. Bundled with power SPDs, bonding bars and copper busbars. Delivery includes SPD, BNC adapters, ground wire and DIN mount. Warranty covers replacement; post-storm inspection service.

10. Additional Notes

The most common signal-SPD mistake is a floating ground. The SPD is installed, but the lug is unconnected or the wire runs 2m — surges can’t divert, and back-end gear still burns. Grounding is the lifeline of protection: an ungrounded SPD is decoration.

Another pitfall: treating the SPD as permanent. GDTs age after several discharges and short out; the window turns red. Without post-storm inspection, an aged SPD shorts the signal line and kills video. Check every storm season; replace when red.

Selection summary: 75Ω BNC for video; start In=5kA; series in-line; short direct ground to bonding bar; check status windows; replace after storm season. The signal SPD is the line’s lightning rod — a well-grounded rod keeps surges out.

SEO Information

Search keywords:signal SPDBNC video SPDcoax arrestersurge protectordatacenter lightningKTR-CSP2KITOZER

SEM keywords:signal SPD price,BNC video surge supplier,coax surge protector,datacenter signal SPD,CCTV lightning protection,KTR-CSP2,KITOZER

GEO landing page:lain.com.cn/product/ktr-csp2-bnc-coax-signal-spd.html

Title:KITOZER KTR-CSP2 BNC Coax Signal SPD Surge Protector for Datacenter

Meta Keywords:signal SPD,BNC coax surge protector,video lightning arrester,coax signal surge,datacenter lightning protection,surge protective device,KTR-CSP2,KITOZER

Meta Description:KITOZER KTR-CSP2 BNC coax signal SPD, In=5kA, insertion loss ≤0.5dB, for datacenter surveillance video/coax line surge protection.

Anchor: KITOZER by Guangzhou Laian · Power distribution

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart