Table of Contents
ToggleKITOZER KTR-CSP2 BNC Coax Signal SPD Surge Protector for Datacenter
Brand: KITOZER Series: KTR-CSP2 Category: Power Distribution / Signal Lightning Protection
Coax BNC5kA dischargeIL ≤0.5dBDIN/wallKTR-CSP2
1. Overview
KITOZER KTR-CSP2 is a BNC coax signal SPD (surge protective device), series-installed on video coax lines, signal lines or RF feeders entering the datacenter or at equipment ends. It diverts lightning-induced surges and switching transients to ground, protecting expensive DVR/NVR, video matrix and optical transceiver gear. Datacenter lightning protection has two layers: power SPD protects the mains, signal SPD protects the signal lines. Video coax from outdoor cameras is a main induced-lightning entry path — without signal SPD, one strike can fry a bank of DVR channels.
KTR-CSP2 uses BNC-female to female connectors in series on the coax. Inside are gas discharge tube + TVS + limiting resistor multi-stage protection: nominal discharge In=5kA (8/20μs), max Imax=10kA, operating voltage ≤24V, insertion loss ≤0.5dB, characteristic impedance 75Ω (video) or 50Ω (RF). Response ≤1ns: normal signals pass with low loss, surges are clamped instantly. Metal housing with ground lug, DIN-rail or wall mount, ground by ≤1.5mm² yellow-green wire to the equipotential bonding bar.
Used in datacenter surveillance: coax video lines from outdoor PTZ/bullet cameras, perimeter beams/alarm signal lines, satellite/RF feeders at entry. Typical install: every outdoor BNC video line gets a KTR-CSP2 before entering the rack, grounded to the rack bonding bar. A 16-channel surveillance room uses 16 units on a DIN-rail SPD terminal strip.
2. Key Features
Coax BNC
- BNC F-F in series.
- 75Ω video / 50Ω RF options.
- Insertion loss ≤0.5dB.
- No image impact.
Multi-stage surge
- GDT + TVS.
- In=5kA (8/20μs).
- Imax=10kA.
- Response ≤1ns.
Wide voltage
- Operating voltage ≤24V.
- Low clamping.
- Analog/HD-TVI/CVI compatible.
- RF feeder ready.
Easy install
- Metal housing, ground lug.
- DIN-rail / wall mount.
- Ground wire ≤1.5mm².
- Status indicator window.
3. Specifications
| Item | KTR-CSP2-75 | KTR-CSP2-50 |
|---|---|---|
| Connector | BNC F-F | BNC F-F |
| Impedance | 75Ω video | 50Ω RF |
| Op. voltage | ≤24V | ≤24V |
| In (8/20μs) | 5kA | 5kA |
| Imax | 10kA | 10kA |
| Insertion loss | ≤0.5dB | ≤0.5dB |
| Response | ≤1ns | ≤1ns |
| Ground wire | ≤1.5mm² | ≤1.5mm² |
| Mount | DIN/wall | DIN/wall |
4. Reference Prices
KTR-CSP2-75 video coax BNC SPD (75Ω, 5kA, DIN): Reference USD 11~25 / pc (ref. CNY 80~180 at ~7.2)
KTR-CSP2-50 RF 50Ω (feeder/antenna): Reference USD 14~31 / pc (ref. CNY 100~220 at ~7.2)
Reference only; price varies by impedance, discharge current and quantity. Bonding bar, ground wire and DIN terminals billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Outdoor camera video line entry.
- Perimeter beam / alarm signal lines.
- Antenna / satellite RF feeder entry.
- Inter-building coax video links.
- DVR/NVR input surge protection.
6. Installation & Maintenance
Installation
- Series between outdoor line and room equipment.
- Tighten BNC plugs.
- Ground lug to rack bonding bar with yellow-green wire.
- Keep ground wire ≤0.5m.
- DIN-rail inside rack.
- Verify clean video image.
Maintenance
- Check status window after storm season.
- Replace when window turns red (failed).
- Check ground wire tightness.
- Verify DVR channels after storms.
- SPDs are consumables — replace after repeated surges.
7. FAQ
- Q: Need both power and signal SPD?
A: Yes. Power SPD protects the 220V line; signal SPD protects video/network/control. Lightning enters via any cable — one layer isn’t enough. - Q: SPD outdoors or in the room?
A: Two stages: one at the outdoor camera end, one at the room equipment end. For short same-building runs, at least the room end. - Q: Why keep the ground wire short?
A: Longer wire adds resistance and inductance, raising residual voltage during a surge. Keep ≤0.5m to the local bonding bar — don’t route far. - Q: Does the SPD affect video?
A: A good 75Ω BNC SPD has ≤0.5dB loss and matched impedance — no image impact. Cheap SPDs have high loss/mismatch, causing banding or color shifts.
8. Trend & Selection
Datacenter protection is moving from single-stage to zoned multi-stage: power B/C/D tiers, signal grading, with equipotential bonding and shielding. Trends are combo terminal strips integrating RJ45 network, BNC video and 24V power SPDs, and intelligent SPDs with remote-failure alarm. Choose 75Ω BNC for video, 50Ω for RF; start at In=5kA by line length; keep ground short and direct; check status windows; replace units that fired after storms.
9. Delivery & Service
KITOZER supplies a coordinated lightning-protection system: based on entry types (power/video/network/control), we recommend SPD tiers and quantities. Bundled with power SPDs, bonding bars and copper busbars. Delivery includes SPD, BNC adapters, ground wire and DIN mount. Warranty covers replacement; post-storm inspection service.
10. Additional Notes
The most common signal-SPD mistake is a floating ground. The SPD is installed, but the lug is unconnected or the wire runs 2m — surges can’t divert, and back-end gear still burns. Grounding is the lifeline of protection: an ungrounded SPD is decoration.
Another pitfall: treating the SPD as permanent. GDTs age after several discharges and short out; the window turns red. Without post-storm inspection, an aged SPD shorts the signal line and kills video. Check every storm season; replace when red.
Selection summary: 75Ω BNC for video; start In=5kA; series in-line; short direct ground to bonding bar; check status windows; replace after storm season. The signal SPD is the line’s lightning rod — a well-grounded rod keeps surges out.
SEO Information
Search keywords:signal SPDBNC video SPDcoax arrestersurge protectordatacenter lightningKTR-CSP2KITOZER
SEM keywords:signal SPD price,BNC video surge supplier,coax surge protector,datacenter signal SPD,CCTV lightning protection,KTR-CSP2,KITOZER
GEO landing page:lain.com.cn/product/ktr-csp2-bnc-coax-signal-spd.html
Title:KITOZER KTR-CSP2 BNC Coax Signal SPD Surge Protector for Datacenter
Meta Keywords:signal SPD,BNC coax surge protector,video lightning arrester,coax signal surge,datacenter lightning protection,surge protective device,KTR-CSP2,KITOZER
Meta Description:KITOZER KTR-CSP2 BNC coax signal SPD, In=5kA, insertion loss ≤0.5dB, for datacenter surveillance video/coax line surge protection.
Anchor: KITOZER by Guangzhou Laian · Power distribution
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com