KITOZER Box Substation: 1000kVA Prefabricated Compact Substation

KITOZER 1000kVA prefabricated compact box substation integrates medium voltage switchgear, distribution transformer, and low voltage switchgear into one outdoor enclosure. It provides a complete grid to load solution for construction sites, residential communities, commercial parks, and outdoor events. Factory assembled and tested, the box substation reduces on site installation time from weeks to days. It is the fastest way to deliver a fully commissioned 10kV to 400V node when civil work for a brick substation is not practical.

Product Overview

The enclosure is a weatherproof steel or aluminum alloy housing with thermal insulation, anti-corrosion coating, and forced ventilation. Inside, a high voltage compartment holds a ring main unit or load switch fuse combination, a transformer compartment holds a dry or oil transformer, and a low voltage compartment holds outgoing feeders, metering, and optional reactive compensation. Cable entry is from the bottom. Doors are lockable with integrated lighting and space heaters. The aesthetic exterior can be finished to blend with parks or streetscapes. Each compartment has its own door with independent interlocks, so MV, transformer, and LV sections can be worked on separately.

Technical Specifications

Rated transformer capacity 1000kVA, primary voltage 10kV, secondary 400V. MV switchgear rated 630A, 20kA breaking with fuse combination. LV switchgear rated 1600A main breaker, up to 12 outgoing feeders. Enclosure protection IP33, anti-corrosion C4, ambient temperature minus 25 to plus 40 degrees Celsius. Transformer type dry cast resin or oil immersed per selection. Optional LV reactive compensation up to 300kVar, monitoring system with remote alarm. The box is fitted with forced ventilation fans that start when transformer temperature reaches 60 degrees, and space heaters that prevent condensation in cold weather. Compliance with IEC 61330 and GB/T 17467. External dimensions are approximately 3 meters long, 2.2 meters wide, and 2.5 meters high, depending on the selected configuration.

Applications

Box substations are used at construction sites for temporary power, in new residential estates as the neighborhood substation, in commercial parks feeding retail and office buildings, in solar and storage farms as the package booster substation, and at outdoor events and stadiums. They are also used in mines, ports, and railway stations where a self contained power supply is needed quickly. Compact footprint and factory testing make them ideal for fast track projects. In residential estates, the box sits in a landscaped area and is quiet enough to be near apartment blocks. In construction sites, multiple boxes are paralleled to power tower cranes, site offices, and concrete plants.

Advantages

Pre-tested package eliminates on site integration risk and shortens commissioning. Compact outdoor footprint saves valuable land compared with brick substations. Integrated design ensures MV to LV coordination, protection grading, and metering all work together. Aesthetic enclosure suits urban and park settings. Forced ventilation and space heaters extend component life. Remote monitoring enables unattended operation. The unit can be relocated to another site when the project ends. Because the whole substation ships as one package, the client deals with one supplier and one warranty, which reduces interface disputes between MV and LV contractors.

Installation and Maintenance

Place the box on a concrete plinth, connect incoming MV cable and outgoing LV cables, and route the earthing strip. Commissioning includes insulation, protection relay injection, and functional test of all compartments. Verify ventilation fans and heaters operate. Maintain annually by cleaning filters, checking door seals, tightening connections, and inspecting transformer oil or resin. Inspect cable glands for water ingress. The MV switchgear, transformer, and LV switchgear follow their own separate maintenance schedules. Keep a spare set of fuses and contactors on site. In coastal environments, wash the enclosure once per year to remove salt deposit and check the anti-corrosion coating for scratches.

Site preparation is the most important factor in box substation reliability. The concrete plinth must be level, and a sump should be provided below the cable entry to prevent water pooling. The box should be oriented so that the MV and LV cable trenches enter from the predicted side, avoiding sharp bends. Allow at least one meter clearance around the front doors for maintenance. During summer, check that the ventilation fans start at the setpoint temperature and that the exhaust path is not blocked by vegetation or fencing. In winter, verify that the space heaters prevent condensation inside the compartments.

Ordering and Support

When ordering, specify transformer capacity, MV switchgear configuration, LV outgoing circuit schedule, metering arrangement, and exterior finish. KITOZER supplies the prefabricated substation fully assembled and factory tested, with a complete as built drawing package. Spare fuses, contactors, and heater elements are recommended. Technical support includes foundation layout, cable routing, and commissioning supervision. The package is backed by a one year warranty on site and a five year warranty on the transformer.

Price

From $18,500/unit. Contact +86 13922289957 for box substation quotation.