KITOZER
KITOZER

KITOZER brush cable mgmt

KITOZER KTR-CM04 Rack Cable Manager with Brush / Horizontal Cable Routing & Dust Protection

Brand: KITOZER Series: KTR-CM04 Category: Data Center Engineering / Cable Manager

horizontalbrush dust1U/2Ucold aisleKTR-CM04

KITOZER KTR-CM04 horizontal rack cable manager with brush for server cabinet cable routing and dust protection

1. Overview

KITOZER KTR-CM04 is a rack cable manager with a brush strip, used as a cable accessory in server racks and modular cold aisle cabinets. As server density rises, hundreds of network, fiber and power cords run between switches, servers and PDUs; without management they pile up above equipment, blocking airflow and slowing maintenance. KTR-CM04 mounts in 1U or 2U space above a switch or patch panel as a horizontal routing trough, gathering cables in layers with tie posts, then letting them drop through the front brush strip to equipment ports.

The brush strip is the key design: a row of flame-retardant nylon brushes embedded in the front panel opening lets cables pass through naturally while sealing the rest of the opening. This stops cold aisle air from leaking through the manager cutout and blocks dust and insects from entering the rack. In modular cold aisles, hot/cold separation is key to efficiency; a plain manager opening short-circuits cold air, and the brush solves that leakage point.

The manager is formed from bent cold-rolled steel with a powder coat, double-sided: a rear vertical routing channel with tie posts and a front brush panel. It mounts to 19-inch standard rack square-hole rails with screws. Variants include single/double-sided and 1U/2U; double-sided routes cables on both sides, suiting bidirectional management above high-density switches. It pairs with vertical managers, PDUs and blanking panels to form the complete rack cable system.

2. Key Features

Brush dust seal

  • Flame-retardant nylon brush; cables pass through.
  • Seals the opening, cutting cold-air leakage.
  • Blocks dust and insects.

Horizontal layered routing

  • 1U/2U height handles high cable counts.
  • Rear tie posts for layered dressing.
  • Front/rear double-sided routing for bidirectional exits.

Structure & install

  • Cold-rolled steel bend, powder coat.
  • Fits 19-inch square-hole rails.
  • Screws and ties included for quick install.

Cold aisle fit

  • Brush seal reduces cold aisle leakage.
  • Works with cold aisle roof and side panels.
  • Maintains hot/cold air separation.

3. Specifications

Item KTR-CM04-1U KTR-CM04-2U KTR-CM04-2UD
Height 1U 2U 2U double
Width 19 inch 19 inch 19 inch
Routing side single single front+rear
Brush strip yes yes both sides
Material steel powder coat steel powder coat steel powder coat
Mounting rail screws rail screws rail screws
Tie posts yes yes both sides

4. Reference Prices

KTR-CM04-1U single brush manager (1U, single side, brush strip): Reference USD 9~17 / piece (ref. CNY 65~120 at ~7.2)

KTR-CM04-2U single brush manager (2U, deeper, tie posts): Reference USD 13~25 / piece (ref. CNY 95~180 at ~7.2)

KTR-CM04-2UD double brush manager (2U double-sided, front/rear brush): Reference USD 21~39 / piece (ref. CNY 150~280 at ~7.2)

Reference only; by height, single/double side and color. Volume discounts for rack projects. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Horizontal routing above switches in server racks.
  • Cable sealing in modular cold aisle cabinets.
  • Cable organization between patch panels and routers.
  • Network/fiber dressing in high-density AI racks.
  • Retrofits of messy existing racks.

6. Installation & Maintenance

Installation

  • Place 1~2U above switch or patch panel.
  • Align to square-hole rails and fix with screws.
  • Bring cables in through the rear vertical channel.
  • Tie in layers on the tie posts.
  • Run cables out through the front brush to ports.
  • Separate power and data cables.
  • Trim excess tie tails.

Maintenance

  • Add new cables through the brush without breaking seal.
  • Check brush for shedding or deformation.
  • Avoid cutting cables when replacing ties.
  • Keep ties loose enough not to pinch cables.

7. FAQ

  • Q: Single or double side?
    A: Choose single if cables exit only the front; choose double if the switch exits both sides (servers front, patch panel rear). Double has brush and tie posts on both sides.
  • Q: 1U or 2U?
    A: Under 24 cables choose 1U; for high-density switches (48+ ports) choose the deeper 2U to avoid cable crush.
  • Q: Does the brush affect cooling?
    A: No. The brush is on the front panel and doesn’t block server intake; it seals the opening and cuts cold-air leakage, helping cold aisle airflow.
  • Q: Can power and data share a trough?
    A: Not recommended. Keep power and data in separate troughs or bundles with spacing to reduce EMI; use a divided manager for high-density racks.

8. Trend & Selection

Cold aisles demand tighter air sealing, pushing managers from simple routing to brush-sealed units that are now standard cold aisle leakage accessories. Choose 1U/2U by cable count, single/double by exit direction, pick brush-sealed for cold aisle racks, separate power and data troughs, and pair with vertical managers for a complete routing system.

9. Delivery & Service

KITOZER selects managers by rack height, switch port density, exit direction and cold aisle sealing needs, configuring 1U/2U and single/double models. We provide a rack cabling diagram. Delivery includes the manager body, brush strip, mounting screws and ties. Warranty covers cabling guidance.

10. Additional Notes

The common pitfall is choosing by 1U/2U height without counting cables. A fully loaded 48-port 10G switch plus server jumpers can fill a 2U manager; crushed cables lose bend radius, raising crosstalk on copper and macro-bend loss on fiber. Calculate manager volume by actual cable count times diameter and leave 30% headroom.

Another pitfall: ties pulled too tight. Crushed copper degrades return loss, and pinched fiber develops micro-bends. Ties should be snug but loose enough to wiggle; keep fiber bend radius and avoid sharp kinks.

Selection summary: choose 1U/2U by cable count with headroom; single/double by exit direction; brush-sealed for cold aisles; separate power and data; tie loosely; pair with vertical managers. A small accessory, yet it decides rack airflow and maintenance efficiency.

SEO Information

Search keywords:cable managerbrush managerhorizontal routingrack accessorycold aisleKTR-CM04KITOZER

SEM keywords:rack cable manager price,brush cable manager supplier,horizontal cable manager,KTR-CM04

GEO landing page:lain.com.cn/product/ktr-cm04-rack-cable-manager-brush.html

Title:KITOZER KTR-CM04 Rack Cable Manager with Brush / Horizontal Cable Routing & Dust Protection

Meta Keywords:rack cable manager,brush cable manager,horizontal cable manager,cable management,cold aisle,brush strip,KTR-CM04,KITOZER

Meta Description:KITOZER KTR-CM04 horizontal rack cable manager with brush strip organizes cables in server racks and cold aisle cabinets while providing dust protection.

Anchor: KITOZER official · Data center & low-voltage equipment