KITOZER Building Energy Conservation Monitoring System Solution

Table of Contents

1. System Overview

The building energy conservation monitoring system is a refined full-energy management platform based on the Internet of Things, big data and edge computing technologies, applicable to public buildings, commercial complexes, industrial plants, data centers and other scenarios. As a core subsystem of intelligent building integration, it realizes closed-loop management of “monitoring-analysis-diagnosis-optimization-control” through real-time collection, precise metering, transmission & storage, multi-dimensional analysis, alarm early warning and energy-saving control of multi-medium energy consumption data including electricity, water, gas, cold/heat and renewable energy. It helps building operation reduce costs and improve efficiency, meets national energy consumption supervision compliance requirements, and supports the implementation of green building and carbon peaking & carbon neutrality goals.

Complying strictly with national standards such as Technical Specification for Remote Monitoring System of Energy Consumption in Public Buildings (JGJ/T 285-2014) and Engineering Technical Specification for Energy Consumption Monitoring System of Large Public Buildings, the KITOZER building energy conservation monitoring system adopts a four-layer “Cloud-Pipe-Edge-Terminal” architecture, featuring full-link compatibility, stable transmission, multi-dimensional analysis and customized expansion. It is suitable for new construction, renovation and expansion projects of all types of buildings, and has been widely deployed in government office buildings, commercial complexes, hotels, hospitals, schools, industrial plants and other scenarios.

2. System Composition

The KITOZER building energy conservation monitoring system consists of four core parts: perception layer, transmission layer, platform layer and application layer. All layers work collaboratively to cover the whole process from energy consumption data collection to application.

2.1 Perception Layer (Data Collection Terminals)

The “nerve endings” of the system, responsible for collecting on-site energy consumption data and equipment operating status. Core equipment includes:

  • Energy consumption metering devices: single/three-phase smart electricity meters, multi-functional power meters, ultrasonic heat meters, photoelectric direct-reading water meters, gas meters, cold meters, etc.
  • Environmental sensing devices: temperature & humidity sensors, differential pressure sensors, air quality sensors, current/voltage transformers (CT/PT)
  • Switch status collection devices: switch quantity collectors, relay modules, smart circuit breakers
  • Edge collection terminals: data collection gateways, embedded collectors, RTU remote terminal units

2.2 Transmission Layer (Data Communication Network)

Guarantees secure, stable and low-latency data transmission, supporting hybrid wired & wireless networking:

  • Wired transmission: RS485 bus, industrial Ethernet, optical fiber communication, Modbus-RTU/TCP protocol
  • Wireless transmission: LoRa, NB-IoT, 4G/5G, Wi-Fi, ZigBee
  • Transmission equipment: industrial switches, optical fiber transceivers, wireless gateways, communication isolators

2.3 Platform Layer (Data Center & Management Platform)

The “brain” of the system, responsible for data storage, processing, analysis, alarm and equipment control. Core components:

  • Hardware platform: industrial servers, data storage arrays, monitoring hosts, UPS uninterruptible power supplies, large-screen display equipment
  • Software platform: KITOZER energy consumption monitoring management system (including data collection, storage, analysis, alarm, report and authority management modules), database software (MySQL/PostgreSQL), edge computing software

2.4 Application Layer (User Interaction & Functional Applications)

Provides visualized and convenient operation & management functions for different user roles:

  • Management terminals: monitoring large screens, PC clients, Web browsers, tablets & mobile APPs
  • Core application functions: real-time energy consumption monitoring, energy consumption statistical analysis, energy consumption alarm & early warning, energy-saving optimization control, report export & printing, data uploading to government platforms, equipment operation & maintenance management, carbon emission accounting

3. System Classification

The KITOZER building energy conservation monitoring system is classified from four dimensions: application scenario, monitoring scope, system architecture and functional positioning, to meet the demands of different projects.

3.1 Classification by Application Scenario

  • Public Building Energy Conservation Monitoring System: government office buildings, office parks, commercial complexes, hotels, hospitals, schools, etc. Focuses on monitoring four major sub-item energy consumption: air conditioning, lighting, power and special electricity.
  • Industrial Building Energy Conservation Monitoring System: factories, workshops, industrial parks. Focuses on monitoring energy consumption of production equipment, air compressors, refrigerating units, boilers and power distribution systems, and supports energy consumption-output correlation analysis.
  • Data Center Energy Conservation Monitoring System: IDC computer rooms and data centers. Focuses on monitoring energy consumption of UPS, precision air conditioners, servers and power distribution systems, and supports real-time PUE (Power Usage Effectiveness) calculation and optimization.
  • Residential Building Energy Conservation Monitoring System: high-end residences, apartments and smart communities. Focuses on household electricity, water and gas consumption monitoring, and supports household energy consumption statistics and cost allocation.
  • Renewable Energy Monitoring System: photovoltaic power stations, energy storage systems, ground-source heat pumps and solar hot water systems. Monitors power generation, energy storage and heat output, and supports renewable energy utilization rate analysis.

3.2 Classification by Monitoring Scope

  • Sub-item Energy Consumption Monitoring System: only monitors four primary sub-item energy consumption of buildings (lighting & socket, air conditioning, power and special electricity) to meet basic compliance requirements.
  • Household/Zonal Energy Consumption Monitoring System: divides monitoring units by floors, tenants, workshops and departments, enabling refined energy consumption allocation and responsibility tracing.
  • Comprehensive Full-energy Monitoring System: fully covers electricity, water, gas, cold/heat, renewable energy, environmental parameters and equipment operating status, supporting multi-dimensional energy consumption analysis and energy-saving optimization.

3.3 Classification by System Architecture

  • Local Centralized Monitoring System: data collection, storage and analysis are completed on local servers, suitable for small buildings and independent buildings without cloud dependence.
  • Cloud-edge Collaborative Monitoring System: edge terminals conduct on-site data collection and preprocessing, while the cloud platform handles big data analysis, remote control and multi-project coordination. Suitable for large buildings, chain commercial properties and industrial parks.
  • Distributed Monitoring System: independent collection in multiple zones, hierarchical transmission and centralized management, suitable for super-large buildings, industrial parks and municipal-level energy consumption supervision platforms.

3.4 Classification by Functional Positioning

  • Basic Energy Consumption Monitoring System: core functions include data collection, real-time display, simple reports and abnormal alarms, meeting basic energy monitoring and compliance reporting demands.
  • Intelligent Energy Consumption Monitoring System: on the basis of basic functions, it adds multi-dimensional energy consumption analysis, energy-saving strategy recommendation, equipment fault diagnosis and carbon emission accounting functions.
  • Smart Energy Consumption Monitoring System: integrated with AI algorithms and digital twins to realize energy consumption prediction, intelligent load regulation, equipment linkage optimization and unmanned operation & maintenance management.

4. System Schematic Principle

Adopting a layered distributed architecture with clear data flow, independent layers and flexible expansion, the system workflow is as follows:

  1. Perception & Collection: On-site smart electricity meters, water meters, heat meters, sensors and collection terminals collect real-time energy consumption data and equipment status signals.
  2. Edge Preprocessing: Data collection gateways/RTUs filter raw data, convert protocols, calibrate precision and eliminate invalid data.
  3. Network Transmission: Processed data is encrypted and uploaded to local servers or cloud platforms via RS485, Ethernet, LoRa, 4G/5G and other communication networks.
  4. Platform Storage & Analysis: The platform layer receives data and performs centralized storage, classified statistics, multi-dimensional analysis (year-on-year/month-on-year, sub-item/household, time period/zone) and anomaly diagnosis.
  5. Application Interaction & Control: Realize visualized display of energy consumption data, alarm information push, energy-saving control instruction issuance and report export & printing through monitoring large screens, PC/APP terminals.
  6. Closed-loop Optimization: The platform generates energy-saving strategies based on analysis results and sends them to on-site controllers/actuators to realize intelligent linkage control of air conditioning, lighting, power distribution and other equipment, reducing energy consumption.

5. Full System Configuration List (3 Grades: Basic, Medium, Advanced, KITOZER Brand)

5.1 Basic Version Configuration List (Small Buildings / Basic Monitoring, within 1,000 ㎡)

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1Three-phase Smart Electricity MeterKTR-DTSD862Accuracy Class: 0.5S; Voltage: 3×220/380V; Current: 1.5(6)A; Communication: RS485, Modbus-RTU; Frequency: 50Hz; Supports active/reactive power & power factor metering8SetKITOZERMain incoming line & key loop monitoring
2Single-phase Smart Electricity MeterKTR-DDS862Accuracy Class: 1.0; Voltage: 220V; Current: 10(40)A; Communication: RS485, Modbus-RTU; Active energy metering15SetKITOZERLighting & socket loop monitoring
3Photoelectric Direct-reading Water MeterKTR-WM200Caliber: DN20; Accuracy Class: 2; Communication: RS485; Working Pressure: 1.6MPa; Reading error ≤1%6SetKITOZERDomestic water monitoring
4Data Collection GatewayKTR-GW100Interfaces: RS485×2, Ethernet×1; Protocols: Modbus-RTU/TCP; Power Supply: DC24V; Local Storage: 8GB; Supports breakpoint resume transmission2SetKITOZERData aggregation & protocol conversion
5Industrial SwitchKTR-SW1005Ports: 5-port 100M; Rate: 10/100Mbps; Power Supply: DC24V; IP30 protection; POE support1SetKITOZERLAN data transmission
6Industrial ServerKTR-SVR100CPU: i3-10105; RAM: 8GB; Storage: 1TB SSD; OS: Windows Server; Interfaces: RS485×2, Ethernet×21SetKITOZERLocal data storage & management
7Basic Energy Consumption Monitoring SoftwareKTR-EMS-BasicFunctions: data collection, real-time display, simple reports, abnormal alarms; PC client only; 1-site authorization1SetKITOZERBasic energy monitoring & management
8UPS Uninterruptible Power SupplyKTR-UPS1000Capacity: 1000VA/600W; Input: 220V±10%; Output: 220V±5%; Backup time ≥30 mins1SetKITOZERServer power failure protection
9Temperature & Humidity SensorKTR-TH100Temp: -20℃~60℃, ±0.5℃ accuracy; Humidity: 0~100%RH, ±3%RH accuracy; RS485 communication; DC24V power supply4SetKITOZERComputer room & key area environmental monitoring
10Distribution BoxKTR-PX300Size: 400×300×200mm; Cold rolled steel; IP54 protection; Equipped with MCB, lightning arrester & terminal blocks2SetKITOZEREquipment integration & protection

5.2 Medium Version Configuration List (Medium Buildings / Intelligent Monitoring, 1,000-5,000 ㎡)

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1Multi-functional Power MeterKTR-PM2000Voltage/current accuracy: 0.2S; active power:0.5S; Measures 3P voltage, current, power, power factor, frequency, harmonic; RS485 Modbus-RTU; AC220V power supply12SetKITOZERMain incoming line & floor power distribution monitoring
2Single-phase Smart Electricity MeterKTR-DDS862Accuracy Class: 1.0; Voltage: 220V; Current:10(40)A; RS485 Modbus-RTU; Active energy metering30SetKITOZERLighting, socket & office equipment loops
3Ultrasonic Heat MeterKTR-HE300Caliber: DN50; Accuracy Class:2; Temp range:0~95℃; RS485; Working pressure:1.6MPa; Bidirectional cold/heat metering8SetKITOZERAir conditioning cold/heat monitoring
4Photoelectric Direct-reading Water MeterKTR-WM200Caliber: DN25; Accuracy Class:2; RS485; Working pressure:1.6MPa; Reading error ≤1%12SetKITOZERDomestic & fire water monitoring
5Gas MeterKTR-GM100Caliber: DN25; Accuracy Class:1.5; RS485; Working pressure:0.1~0.5MPa; Natural gas/LPG metering4SetKITOZERKitchen & boiler room gas monitoring
6Data Collection GatewayKTR-GW200Interfaces: RS485×4, Ethernet×2, LoRa×1; Protocols: Modbus-RTU/TCP, DL/T 645; DC24V; 32GB storage; Edge computing & breakpoint resume4SetKITOZERMulti-protocol data aggregation & preprocessing
7Industrial SwitchKTR-SW10088-port 100M RJ45; 10/100Mbps adaptive; DC24V; IP30; POE & VLAN support2SetKITOZERMulti-zone network transmission
8Industrial ServerKTR-SVR200CPU: i5-11400; RAM:16GB; 2TB SSD; Windows Server; RS485×4, Ethernet×2; Dual hot standby support1SetKITOZERData storage, analysis & management
9Intelligent Energy Monitoring SoftwareKTR-EMS-SmartReal-time data, multi-dimensional analysis, alarm warning, report export, carbon accounting; PC/Web/Tablet support; 3-site authorization1SetKITOZERIntelligent energy management & analysis
10UPS Uninterruptible Power SupplyKTR-UPS20002000VA/1200W; Input 220V±15%; Output 220V±3%; Backup ≥60 mins; Voltage stabilization & surge protection1SetKITOZERSystem power failure protection & voltage regulation
11Temp & Humidity SensorKTR-TH200Temp: -30℃~70℃, ±0.3℃; Humidity:0~100%RH, ±2%RH; RS485; DC24V; Dustproof & waterproof8SetKITOZERFloor, computer room & air conditioning zone monitoring
12Current TransformerKTR-CT300Ratio:200/5A; Accuracy Class:0.5; 50Hz; Class B insulation; Matches three-phase meters24SetKITOZERHigh-current loop monitoring
13Monitoring Large ScreenKTR-LCD5555-inch; 1920×1080 resolution; 500cd/㎡ brightness; HDMI/VGA; 7×24h continuous operation1SetKITOZERVisualized energy data display
14Distribution BoxKTR-PX400Size:500×400×250mm; Sprayed cold rolled steel; IP55; Equipped with lightning arrester, MCB & surge protector4SetKITOZEREquipment integration & safety protection

5.3 Advanced Version Configuration List (Large Buildings / Smart Monitoring, over 5,000 ㎡ / Industrial Parks)

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1Multi-functional Power AnalyzerKTR-PM3000Voltage/current:0.2S; active power:0.2S, reactive:0.5S; Measures 2-50th harmonic, demand & power quality; RS485/Ethernet Modbus; AC/DC85-265V wide power supply20SetKITOZERMain incoming line, high voltage side & key equipment monitoring
2Smart Prepayment Electricity MeterKTR-DTSD863Accuracy 0.5S; 3×220/380V; 5(20)A; RS485/Ethernet; Remote recharge, power-off trip & time-of-use billing50SetKITOZERTenant/household energy metering & control
3Ultrasonic Heat MeterKTR-HE500Caliber DN80-DN150; Accuracy Class 1; Temp -20℃~120℃; Ethernet/RS485; Working pressure 2.5MPa; Bidirectional cold/heat metering15SetKITOZERCentral air conditioning & district cooling/heating monitoring
4Electromagnetic Water MeterKTR-WM500Caliber DN50-DN200; Accuracy Class 0.5; Ethernet/RS485; 2.5MPa; 304 stainless steel, corrosion-resistant & anti-interference20SetKITOZERIndustrial & commercial large flow water monitoring
5Intelligent Gas MeterKTR-GM200Caliber DN50; Accuracy Class1.0; Ethernet/RS485; 0.1~1.0MPa; Remote meter reading & leakage alarm8SetKITOZERBoiler room, canteen & production gas monitoring
6Edge Computing GatewayKTR-GW300RS485×8, Ethernet×4, LoRa×2, 4G/5G×1; Protocols Modbus-RTU/TCP, DL/T645, MQTT, BACnet; DC24V; 128GB storage; AI edge computing, encryption & breakpoint resume8SetKITOZERMulti-zone & multi-protocol data processing & transmission
7Industrial Core SwitchKTR-SW202424-port Gigabit + 4 optical ports; 10/100/1000Mbps; DC24V; IP40; POE, VLAN & link aggregation support4SetKITOZERPark & large building backbone network
8Data Center ServerKTR-SVR300CPU Xeon E3-1230; RAM32GB; 4TB SSD+8TB HDD; Windows Server; RS485×8, Ethernet×4; Dual hot standby & cluster deployment2SetKITOZERData storage, AI analysis & platform management
9Smart Energy Monitoring SoftwareKTR-EMS-WiseReal-time collection, AI prediction, multi-dimensional analysis, fault diagnosis, energy-saving control, carbon accounting, digital twin; PC/Web/Tablet/Mobile APP; Unlimited site authorization1SetKITOZERSmart energy management & optimization control
10UPS Uninterruptible Power SupplyKTR-UPS60006000VA/3600W; Input 220V±20%; Output 220V±1%; Backup ≥120 mins; Voltage stabilization, surge protection & battery management2SetKITOZERDual-circuit power failure protection & voltage regulation
11Temp/Humidity/Differential Pressure SensorKTR-THP300Temp -40℃~80℃, ±0.2℃; Humidity 0~100%RH, ±1.5%RH; Differential pressure 0~5000Pa, ±1%FS; Ethernet/RS485; DC24V20SetKITOZERPrecise environmental monitoring for air conditioning, computer rooms & workshops
12Current/Voltage TransformerKTR-CT/PT500CT ratio 500/5A, 0.2S accuracy; PT ratio 10000/100V, 0.2 accuracy; 50Hz; Class F insulation; Matches high voltage & high-current loops40SetKITOZERPrecise monitoring for high voltage & high-current loops
134K HD Monitoring Large ScreenKTR-LCD8686-inch; 3840×2160 4K; 700cd/㎡; HDMI2.0/DP; 7×24h operation & splicing expansion support2SetKITOZERVisual display of energy data & equipment status
14Intelligent Control TerminalKTR-CTRL1008-channel switch output; RS485/Ethernet; DC24V; Remote/automatic control for air conditioning, lighting & fans15SetKITOZERLinked control of energy-consuming equipment
15Lightning Protection Distribution BoxKTR-PX500Size 600×500×300mm; 304 stainless steel; IP65; Equipped with Class 3 lightning arrester, MCB, surge protector & ground terminal8SetKITOZEREquipment protection for outdoor & industrial scenarios
16Data Backup Storage NASKTR-NAS400016TB capacity; Dual Ethernet; Embedded OS; Automatic backup, remote synchronization & authority management1SetKITOZERSecure backup of energy consumption data

6. Full Product Technical Parameters

6.1 Smart Electricity Meter Series

KTR-DTSD862 Three-phase Smart Electricity Meter

  • Accuracy Class: 0.5S (active power), Class 2 (reactive power)
  • Rated Voltage: 3×220/380V, ±10%
  • Rated Current: 1.5(6)A, 5(20)A, 10(40)A optional
  • Communication: RS485, Modbus-RTU
  • Frequency: 50Hz, ±0.5Hz
  • Metering Functions: Forward/reverse active power, four-quadrant reactive power, power, power factor, frequency
  • Operating Temperature: -20℃~60℃
  • Protection Class: IP51
  • Dimensions: 170×102×65mm

KTR-PM2000 Multi-functional Power Meter

  • Accuracy: Voltage/current 0.2S, active power 0.5S, reactive power 1.0
  • Measurable Parameters: 3P voltage, current, active/reactive/apparent power, power factor, frequency, 2-31st harmonic, demand
  • Communication: Dual RS485 ports, Modbus-RTU
  • Power Supply: AC/DC85-265V wide voltage input
  • Display: LCD real-time data screen
  • Operating Temperature: -30℃~70℃
  • Protection: IP54 (panel), IP30 (housing)
  • Dimensions: 96×96×80mm

6.2 Energy Consumption Meter Series

KTR-HE300 Ultrasonic Heat Meter

  • Accuracy Class: Class 2 (DN50 and below), Class1 (DN80 and above)
  • Caliber Options: DN20, DN25, DN50, DN80, DN100
  • Temperature Range: 0~95℃ (cold water), 0~120℃ (hot water)
  • Communication: RS485 Modbus-RTU, M-Bus compatible
  • Working Pressure: 1.6MPa (DN50 and below), 2.5MPa (DN80 and above)
  • Flow Range: 0.01~100m³/h (matched by caliber)
  • Operating Temperature: -20℃~60℃
  • Protection Class: IP65
  • Material: Brass (DN50 and below), Cast iron (DN80 and above)

KTR-WM200 Photoelectric Direct-reading Water Meter

  • Accuracy Class: Class 2
  • Caliber Options: DN15, DN20, DN25, DN32
  • Communication: RS485 Modbus-RTU, remote meter reading supported
  • Working Pressure: 1.6MPa
  • Reading Error: ≤1%
  • Operating Temperature: 0~40℃ (cold water), 0~90℃ (hot water)
  • Protection Class: IP68
  • Material: Copper alloy
  • Dimensions: 150×80×50mm

6.3 Data Collection & Transmission Equipment Series

KTR-GW200 Data Collection Gateway

  • Interfaces: RS485×4, Ethernet×2, LoRa×1
  • Supported Protocols: Modbus-RTU/TCP, DL/T645, MQTT, BACnet
  • Power Supply: DC24V ±10%
  • Local Storage: 32GB, cache up to 1 million data records
  • Transmission Distance: RS485 ≤1200m, LoRa ≤3km (open space)
  • Operating Temperature: -40℃~75℃
  • Protection Class: IP30
  • Dimensions: 150×120×40mm
  • Core Functions: Protocol conversion, data preprocessing, breakpoint resume, edge computing

KTR-SW1008 Industrial Switch

  • Ports: 8-port 100M RJ45, IEEE802.3af POE supported
  • Transmission Rate: 10/100Mbps adaptive
  • Power Supply: DC24V ±10%
  • Switching Capacity: 1.6Gbps
  • Operating Temperature: -30℃~70℃
  • Protection Class: IP30
  • Dimensions: 120×80×30mm
  • Core Functions: VLAN division, port isolation, link aggregation, fault self-recovery

6.4 Sensing Equipment Series

KTR-TH200 Temperature & Humidity Sensor

  • Temperature Measurement Range: -30℃~70℃, ±0.3℃ accuracy
  • Humidity Measurement Range: 0~100%RH, ±2%RH accuracy
  • Communication: RS485 Modbus-RTU
  • Power Supply: DC24V ±10%
  • Response Time: ≤10s
  • Operating Temperature: -30℃~70℃
  • Protection Class: IP65
  • Dimensions: 80×60×25mm
  • Installation: Wall-mounted / Duct-mounted optional

KTR-CT300 Current Transformer

  • Transformation Ratio: 50/5A ~ 2000/5A optional, Class 0.5 accuracy
  • Rated Frequency: 50Hz
  • Insulation Class: Class B (130℃ heat resistance)
  • Rated Load: 5VA
  • Operating Temperature: -20℃~60℃
  • Protection Class: IP40
  • Dimensions: Matched to transformation ratio (aperture 10-50mm)
  • Core Function: Convert high current to standard 5A signal for matching meters & instruments

6.5 Software & Platform Series

KTR-EMS-Smart Intelligent Energy Monitoring Software

  • Architecture: Mixed B/S + C/S, compatible with Windows/Linux
  • Database: MySQL/PostgreSQL, encrypted storage supported
  • Concurrent Users: ≥50 online simultaneously
  • Equipment Access: Supports over 1,000 devices, adjustable collection cycle 1-60s
  • Analysis Functions: Year-on-year/month-on-year, sub-item/household, time/zone analysis, energy consumption ranking, anomaly diagnosis
  • Alarm Functions: Threshold alarm, trend alarm, equipment offline alarm, SMS/APP push notification
  • Report Functions: Daily/weekly/monthly/annual reports, Excel/PDF export, custom templates
  • Extended Functions: Carbon emission accounting, energy-saving strategy recommendation, equipment operation & maintenance management
  • Authorization: By site/equipment quantity, lifetime authorization available

6.6 Auxiliary Equipment Series

KTR-UPS2000 Uninterruptible Power Supply

  • Capacity: 2000VA/1200W
  • Input Voltage: 220V±15%, 50Hz±5%
  • Output Voltage: 220V±3%, pure sine wave
  • Backup Time: ≥60 mins under full load
  • Battery: Built-in 12V/7AH×2 maintenance-free lead-acid battery
  • Operating Temperature: 0~40℃
  • Protection Class: IP20
  • Dimensions: 350×150×200mm
  • Core Functions: Power failure protection, voltage stabilization, surge protection, battery monitoring

7. Full Product Application Scope

7.1 Smart Electricity Meter Series Application

  • KTR-DTSD862 Three-phase Smart Electricity Meter: Main incoming lines of public buildings, floor power distribution, factory workshops, commercial complex tenants, UPS input/output loops of data centers, for precise three-phase energy metering & monitoring.
  • KTR-DDS862 Single-phase Smart Electricity Meter: Office building lighting & socket circuits, office equipment, hotel rooms, residential households, mall shops, for household/zonal energy metering.
  • KTR-PM2000 Multi-functional Power Meter: High & low voltage power distribution rooms, air conditioning machine rooms, pump rooms, elevator machine rooms of buildings, monitors voltage, current, harmonic and power parameters to guarantee power utilization safety.
  • KTR-PM3000 Multi-functional Power Analyzer: Large buildings, industrial parks, high voltage sides of data centers, transformers, large refrigerating units and air compressors, for power quality analysis, precise energy metering and fault diagnosis.

7.2 Energy Consumption Meter Series Application

  • KTR-HE300/500 Ultrasonic Heat Meter: Central air conditioning cold/hot water systems, district cooling & heating pipe networks, hotel/hospital hot water systems, industrial cooling circulating water systems, precisely measures cold & heat consumption to support air conditioning energy-saving optimization.
  • KTR-WM200/500 Water Meter: Building domestic water, fire water, air conditioning makeup water, industrial production water, landscape irrigation water, realizes water consumption monitoring & water-saving management.
  • KTR-GM100/200 Gas Meter: Hotel kitchens, canteens, boiler rooms, industrial gas production equipment, gas heating systems, monitors gas consumption and prevents gas leakage risks.

7.3 Data Collection & Transmission Equipment Application

  • KTR-GW100/200/300 Collection Gateway: All types of building energy data collection scenarios, connects electricity meters, water meters, heat meters, sensors and other terminals, realizes multi-protocol conversion, data preprocessing & remote transmission, applicable to small buildings, medium office buildings and large industrial parks.
  • KTR-SW1005/1008/2024 Industrial Switch: Weak current machine rooms, floor weak current shafts, industrial park backbone networks, provides stable network transmission for collection terminals, gateways and servers, POE power supply simplifies wiring.
  • KTR-CTRL100 Intelligent Control Terminal: Remote/automatic control of air conditioning, lighting, fans and water pumps, realizes linkage of energy consumption data and equipment control to reduce invalid energy consumption.

7.4 Sensing Equipment Application

  • KTR-TH100/200/300 Temp & Humidity Sensor: Computer rooms, air conditioning zones, warehouses, production workshops, museums and archives, monitors environmental temperature & humidity to provide data support for air conditioning optimization and equipment operation environment guarantee.
  • KTR-THP300 Temp/Humidity/Differential Pressure Sensor: Clean workshops, hospital operating rooms, cold aisles of data centers, air conditioning filter screens, monitors differential pressure and temperature & humidity to guarantee environmental cleanliness and efficient air conditioning operation.
  • KTR-CT/PT Current/Voltage Transformer: High voltage/high-current power distribution loops, transformers and large motors, converts high voltage/high current into standard signals for precise monitoring by meters & instruments.

7.5 Software & Platform Application

  • KTR-EMS-Basic/Smart/Wise Energy Monitoring Software: Matches small buildings (basic monitoring), medium office buildings (intelligent analysis), large buildings & industrial parks (smart optimization), covers full-scenario energy management demands of public buildings, industrial buildings, data centers and residential buildings.

7.6 Auxiliary Equipment Application

  • KTR-UPS Uninterruptible Power Supply: Weak current machine rooms, servers, gateways and monitoring large screens, guarantees continuous system operation after power failure and prevents data loss.
  • KTR-PX Distribution Box: Building weak current shafts, machine rooms and outdoor equipment cabinets, integrates collection terminals, gateways and switches, provides protection, lightning protection and wiring functions.
  • KTR-LCD Monitoring Large Screen: Building central control rooms, property offices and industrial park management centers, real-time displays energy consumption data, equipment status and alarm information to improve management visualization.

8. Full Product Advantages

8.1 Core Brand Advantages of KITOZER

  • Full independent R&D: Self-developed & manufactured from perception terminals, transmission equipment to software platforms, mastering core technologies and supporting in-depth customization & function expansion.
  • Customized service capability: Provides customized solutions according to project scenarios (public building/industrial/data center), monitoring demands (sub-item/household/full-energy) and budgets (basic/medium/advanced), adapting to all types of projects.
  • OEM/ODM service: Supports customer brand OEM production, customized product development and customized scheme design, provides full-process OEM service from hardware production to software deployment.
  • Strict confidentiality mechanism: Strictly keeps confidential customer project schemes, technical parameters, customized demands and commercial information, signs confidentiality agreements to avoid information leakage.
  • Stable spot supply: Core products (electricity meters, water meters, gateways, sensors) are stocked in large quantities, supporting fast delivery & emergency replenishment to shorten project delivery cycles.
  • Full-chain technical support: Provides full-process technical support including scheme design, product selection, on-site installation, commissioning training and after-sales maintenance to guarantee smooth project delivery.

8.2 Hardware Product Advantages

(1) Smart Electricity Meter & Instrument Series

  • High-precision metering: Imported core metering chips, precision up to 0.2S level, metering error far below national standards to ensure accurate & reliable data.
  • Wide voltage & wide temperature design: Supports AC/DC85-265V wide voltage power supply, operating temperature -40℃~75℃, adapting to high/low temperature, humid and dusty harsh environments.
  • Strong anti-interference capability: EMC Level 4 electromagnetic compatibility design, anti-static, anti-surge and anti-electromagnetic interference, stable operation under complex power distribution environments.
  • Long service life: Flame-retardant ABS/cold rolled steel housing, industrial-grade internal components, service life ≥10 years to reduce replacement costs.
  • Multi-protocol compatibility: Supports mainstream protocols including Modbus-RTU/TCP and DL/T645, seamlessly connects mainstream domestic and foreign platforms with strong compatibility.

(2) Energy Consumption Meter Series

  • High protection class: Water/heat meters reach IP65/IP68 dustproof & waterproof, adapting to harsh installation environments such as outdoors, humid areas and underwater.
  • Tamper-proof design: Built-in anti-tamper chips; opening or disassembly of the meter will be automatically recorded and uploaded as an alarm, eliminating artificial data tampering and guaranteeing data authenticity.
  • Full caliber coverage: Heat/water meters support DN15-DN200 full calibers, matching all pipe diameter demands from small buildings to large industrial parks.
  • Bidirectional metering: Heat meters support bidirectional cold & heat metering, adapting to dual working conditions of air conditioning cooling and heating.

(3) Collection & Transmission Equipment Series

  • Multi-interface expansion: Gateways support RS485, Ethernet, LoRa, 4G/5G multi-interfaces, can access different types of terminals with different protocols simultaneously for strong expandability.
  • Edge computing capability: Advanced gateways are equipped with AI edge computing chips, supporting local data preprocessing, anomaly diagnosis and energy-saving strategy execution to reduce cloud dependence.
  • Breakpoint resume transmission: Automatically caches up to 1 million data records during network disconnection, automatically supplements data after network recovery to avoid data loss.
  • Industrial reliability: Metal housing & fanless design for switches & gateways, anti-vibration and dustproof, adapting to harsh environments such as industrial sites and outdoor cabinets.

(4) Sensing Equipment Series

  • Ultra-high precision: Temperature & humidity sensor precision up to ±0.2℃, ±1.5%RH; differential pressure sensor precision ±1%FS, meeting precise environmental monitoring demands.
  • Fast response: Response time ≤10s, captures real-time changes of environmental parameters to provide timely data support for system regulation.
  • Long-distance transmission: RS485/LoRa communication with long transmission distance and stable signals, adapting to long-distance monitoring scenarios of large buildings and industrial parks.

8.3 Software Platform Advantages

  • Full-function integration: Integrates data collection, real-time monitoring, multi-dimensional analysis, alarm early warning, energy-saving control, carbon emission accounting, report export and operation & maintenance management, one-stop solution for energy management.
  • AI intelligent analysis: Advanced version built-in AI algorithms, supporting energy consumption prediction, fault diagnosis and automatic energy-saving strategy recommendation, upgrading from “monitoring” to “optimization”.
  • Visual interaction: Large-screen visualization & 3D digital twin technology, intuitively displays energy distribution, equipment status and alarm information with simple & friendly operation interface.
  • Multi-terminal adaptation: Accessible via PC, Web, tablet and mobile APP, allowing real-time data viewing, alarm receiving and remote control anytime anywhere.
  • High compatibility: Supports Windows/Linux/Kylin domestic OS, seamlessly connects government energy supervision platforms, intelligent building systems and BA systems to meet compliance & integration demands.
  • Data security guarantee: Encrypted data transmission & storage, hierarchical authority management and operation log traceability to prevent data leakage & tampering.

9. Bid-winning Technical Parameters for All Products (Marked with ★)

9.1 Smart Electricity Meter Series Bid-winning Parameters

KTR-DTSD862 Three-phase Smart Electricity Meter

★ Accuracy Class: 0.5S (active power) ★ Rated Voltage: 3×220/380V, ±10% ★ Communication Interface: RS485, Modbus-RTU protocol ★ Operating Temperature: -20℃~60℃ ★ Protection Class: IP51

KTR-PM2000 Multi-functional Power Meter

★ Accuracy: Voltage/current 0.2S, active power 0.5S ★ Measurable Parameters: Supports 2-31st harmonic measurement ★ Communication: Dual RS485 ports, Modbus-RTU protocol ★ Power Supply: AC/DC85-265V wide voltage ★ Operating Temperature: -30℃~70℃

9.2 Energy Consumption Meter Series Bid-winning Parameters

KTR-HE300 Ultrasonic Heat Meter

★ Accuracy Class: Class 2 (DN50 and below) ★ Caliber: DN20~DN100 optional ★ Communication: RS485, Modbus-RTU protocol ★ Working Pressure: 1.6MPa ★ Protection Class: IP65

KTR-WM200 Photoelectric Direct-reading Water Meter

★ Accuracy Class: Class 2 ★ Caliber: DN15~DN32 optional ★ Communication: RS485, Modbus-RTU protocol ★ Working Pressure: 1.6MPa ★ Protection Class: IP68

9.3 Data Collection & Transmission Equipment Bid-winning Parameters

KTR-GW200 Data Collection Gateway

★ Communication Interfaces: RS485×4, Ethernet×2, LoRa×1 ★ Supported Protocols: Modbus-RTU/TCP, DL/T645, MQTT ★ Local Storage: 32GB, cache ≥1 million data records ★ Power Supply: DC24V ±10% ★ Operating Temperature: -40℃~75℃

KTR-SW1008 Industrial Switch

★ Ports: 8-port 100M, IEEE802.3af POE supported ★ Transmission Rate: 10/100Mbps adaptive ★ Switching Capacity: 1.6Gbps ★ Operating Temperature: -30℃~70℃ ★ Protection Class: IP30

9.4 Sensing Equipment Bid-winning Parameters

KTR-TH200 Temperature & Humidity Sensor

★ Temperature Accuracy: ±0.3℃ (-30℃~70℃) ★ Humidity Accuracy: ±2%RH (0~100%RH) ★ Communication: RS485, Modbus-RTU protocol ★ Power Supply: DC24V ±10% ★ Protection Class: IP65

KTR-CT300 Current Transformer

★ Accuracy: Class 0.5 ★ Transformation Ratio: 50/5A~2000/5A optional ★ Rated Frequency: 50Hz ★ Insulation Class: Class B ★ Operating Temperature: -20℃~60℃

9.5 Software Platform Bid-winning Parameters

KTR-EMS-Smart Intelligent Energy Monitoring Software

★ Architecture: Mixed B/S + C/S ★ Database: MySQL/PostgreSQL, encrypted storage supported ★ Concurrent Online Users: ≥50 ★ Adjustable Collection Cycle: 1-60s ★ Alarm Function: SMS/APP push notification supported ★ Report Function: Custom templates & Excel/PDF export supported

9.6 Auxiliary Equipment Bid-winning Parameters

KTR-UPS2000 Uninterruptible Power Supply

★ Capacity: 2000VA/1200W ★ Input Voltage: 220V±15% ★ Output Voltage: 220V±3%, pure sine wave ★ Full-load Backup Time: ≥60 mins ★ Operating Temperature: 0~40℃

10. Full Product Solutions

10.1 Public Building Energy Conservation Monitoring Solution (Office Parks / Commercial Complexes / Hotels)

Demand Pain Points

  1. Complex energy consumption structure (electricity, water, gas, cold & heat), low efficiency & large error of manual meter reading
  2. High energy consumption of air conditioning, lighting and elevators without refined control tools
  3. Opaque tenant energy allocation leading to frequent disputes
  4. Compliance reporting requirements for national energy supervision without unified data platform

Solution

Adopt KITOZER medium/advanced version system to build a sub-item + household full-energy monitoring system:

  1. Perception Layer: Deploy KTR-PM2000 multi-functional power meters on main incoming lines, KTR-DTSD863 smart meters for floors & tenants, KTR-HE300 heat meters for air conditioning systems, KTR-WM200 water meters for domestic water, KTR-GM100 gas meters for gas systems, KTR-TH200 temp & humidity sensors in key zones.
  2. Transmission Layer: Hybrid RS485 + Ethernet networking, deploy KTR-GW200 gateways & KTR-SW1008 switches to guarantee stable data transmission.
  3. Platform Layer: Deploy KTR-EMS-Smart intelligent software, connect to government energy supervision platforms to realize compliant data reporting.
  4. Application Layer: Realize real-time energy monitoring, automatic tenant energy allocation, intelligent air conditioning & lighting control and alarm warning via monitoring large screens & APP terminals, cutting operation costs by 15%-25%.

10.2 Industrial Building Energy Conservation Monitoring Solution (Factories / Workshops / Industrial Parks)

Demand Pain Points

  1. High energy consumption of production equipment (motors, air compressors, refrigerating units), lack of energy-output correlation analysis
  2. Workshop environment (temperature, humidity, differential pressure) affects production quality requiring synchronous monitoring
  3. Equipment faults lead to sharp energy consumption spikes without early warning mechanism
  4. Scattered multiple factory buildings in industrial parks requiring centralized management & unified analysis

Solution

Adopt KITOZER advanced version system to build an integrated monitoring system of full energy, equipment status & environmental parameters:

  1. Perception Layer: Deploy KTR-PM3000 power analyzers on high voltage sides, KTR-DTSD862 electricity meters & KTR-CT300 transformers for production equipment, KTR-HE500 heat meters for cooling circulating water, KTR-THP300 temp/humidity/differential pressure sensors in workshops, switch quantity collectors for key equipment.
  2. Transmission Layer: Ethernet + 4G/5G networking, deploy KTR-GW300 edge computing gateways & KTR-SW2024 core switches to realize centralized data transmission of multiple factories.
  3. Platform Layer: Deploy KTR-EMS-Wise smart software integrated with AI algorithms to realize energy-output correlation analysis, equipment fault diagnosis and energy-saving strategy recommendation.
  4. Application Layer: Realize centralized control & intelligent optimization via digital twin large screens displaying energy consumption, equipment operation status and environmental parameters of all workshops, cutting industrial energy consumption by 20%-30%.

10.3 Data Center Energy Conservation Monitoring Solution (IDC Computer Rooms / Data Centers)

Demand Pain Points

  1. High PUE (Power Usage Effectiveness), energy consumption of UPS & precision air conditioning accounts for over 40%
  2. Precise monitoring of computer room temperature, humidity, differential pressure and cabinet microenvironment required to guarantee equipment safety
  3. Lack of real-time PUE calculation & optimization tools, difficulty meeting green data center standards
  4. Equipment faults easily cause data center outage requiring 7×24h monitoring & early warning

Solution

Adopt KITOZER advanced version system to build a smart monitoring system integrating PUE monitoring, cabinet microenvironment & equipment control:

  1. Perception Layer: Deploy KTR-PM3000 power analyzers on UPS input/output, KTR-HE300 heat meters for precision air conditioning, KTR-THP300 temp/humidity/differential pressure & current sensors on cabinets, KTR-DTSD862 electricity meters in power distribution cabinets.
  2. Transmission Layer: Industrial Ethernet networking, deploy KTR-GW300 gateways & KTR-SW2024 switches to guarantee high-speed & stable data transmission.
  3. Platform Layer: Deploy KTR-EMS-Wise smart software with built-in PUE calculation model, real-time PUE monitoring, analysis of UPS & air conditioning energy proportion and optimization strategy generation.
  4. Application Layer: Real-time display of PUE value, cabinet microenvironment parameters and equipment energy consumption via monitoring large screens, realize intelligent air conditioning regulation & load balancing optimization, reduce PUE below 1.4 and cut energy consumption by 25%-35%.

10.4 Small Building Energy Conservation Monitoring Solution (Office Shops / Small Factories)

Demand Pain Points

  1. Limited budget requiring low-cost & easy-to-deploy monitoring scheme
  2. Only basic energy monitoring, simple reports and abnormal alarm functions needed
  3. Short construction cycle without complex wiring

Solution

Adopt KITOZER basic version system to build a basic sub-item energy consumption monitoring system:

  1. Perception Layer: Deploy KTR-DTSD862 three-phase meters on main incoming lines, KTR-DDS862 single-phase meters for lighting & socket loops, KTR-WM200 water meters for domestic water, KTR-TH100 temp & humidity sensors in computer rooms.
  2. Transmission Layer: RS485 bus networking, deploy KTR-GW100 gateways & KTR-SW1005 switches with simple wiring & low cost.
  3. Platform Layer: Deploy KTR-EMS-Basic basic software to realize data collection, real-time display, simple reports and abnormal alarms.
  4. Application Layer: Check energy data, export reports and receive alarm information via PC clients to meet basic energy monitoring & compliance demands, construction cycle ≤3 days.

11. Full Product Application Cases

11.1 Grade A Office Building Project in Guangzhou

  • Project Overview: Construction area 32,000 ㎡, 28 floors above ground & 2 underground floors. Core demands: sub-item energy monitoring, tenant energy allocation & air conditioning energy-saving optimization.
  • System Configuration: KITOZER medium version system, 32 multi-functional power meters, 120 smart electricity meters, 15 ultrasonic heat meters, 28 water meters, 45 temp & humidity sensors, 8 collection gateways, 5 industrial switches, 1 set intelligent software, 1 55-inch monitoring large screen.
  • Application Effect: Real-time monitoring of four major sub-item energy consumption (lighting, air conditioning, power, special electricity), automatic tenant energy allocation and intelligent air conditioning regulation; building operation energy consumption reduced by 22%, annual electricity saving of about RMB 1.8 million, meeting compliance reporting requirements of Guangzhou municipal energy supervision platform.

11.2 Electronic Industrial Park Project in Dongguan

  • Project Overview: Park covers 80,000 ㎡, including 6 production workshops, 2 office buildings and 1 canteen. Core demands: centralized energy monitoring of multiple factories, production equipment energy analysis & workshop environmental monitoring.
  • System Configuration: KITOZER advanced version system, 40 multi-functional power analyzers, 200 smart electricity meters, 30 ultrasonic heat meters, 25 electromagnetic water meters, 60 temp/humidity/differential pressure sensors, 15 edge computing gateways, 8 core switches, 1 set smart software, 2 86-inch monitoring large screens.
  • Application Effect: Centralized energy management of 6 workshops, energy-output correlation analysis, real-time monitoring & alarm of workshop temperature, humidity & differential pressure; AI energy-saving strategy optimization cuts production equipment energy consumption by 28%, annual energy cost saving of about RMB 3.5 million, equipment fault early warning accuracy reaches 95%.

11.3 Data Center Project in Shenzhen

  • Project Overview: Construction area 15,000 ㎡, 800 cabinets. Core demands: real-time PUE monitoring, cabinet microenvironment monitoring & UPS/precision air conditioning energy optimization.
  • System Configuration: KITOZER advanced version system, 25 multi-functional power analyzers, 80 smart electricity meters, 12 ultrasonic heat meters, 120 temp/humidity/differential pressure sensors, 10 edge computing gateways, 6 core switches, 1 set smart software, 1 86-inch monitoring large screen.
  • Application Effect: Real-time PUE calculation (PUE reduced from 1.68 to 1.39), precise cabinet microenvironment monitoring, UPS load balancing optimization & intelligent precision air conditioning regulation; data center energy consumption cut by 32%, annual electricity saving of about RMB 2.6 million, guarantees 7×24h safe & stable operation of the data center.

11.4 Small Commercial Complex Project in Foshan

  • Project Overview: Construction area 8,000 ㎡, 5 floors above ground including shops, supermarkets and catering. Core demands: basic energy monitoring, cost control & compliance reporting.
  • System Configuration: KITOZER basic version system, 12 three-phase smart electricity meters, 40 single-phase smart electricity meters, 15 water meters, 8 temp & humidity sensors, 3 collection gateways, 2 industrial switches, 1 set basic software.
  • Application Effect: Real-time monitoring of total & sub-item energy consumption, simple report export & abnormal alarm; low investment cost & short construction cycle (2 days deployment), meets Foshan municipal energy supervision compliance requirements, annual energy cost saving of about RMB 450,000.

12. Common Product Faults & Maintenance

12.1 Smart Electricity Meter & Instrument Faults & Maintenance

Common Faults

  1. No display: Power supply failure, loose power wire, damaged internal power module of the meter
  2. Unupdated/jumping data: Communication line fault, wrong RS485 wiring, conflicting terminal address, damaged metering chip
  3. Large metering error: Meter precision drift, wrong transformer ratio, wrong wiring, low load power factor
  4. Frequent alarms: Over-limit voltage/current, excessive harmonic, meter fault

Maintenance Rules

  • Daily Inspection: Check meter appearance, wiring tightness and display monthly, record operating status
  • Annual Calibration: Entrust third-party institutions to calibrate meter precision every year to ensure error within allowable range
  • Communication Maintenance: Inspect RS485 lines & joints for aging/damage quarterly, re-tighten wiring to avoid poor contact
  • Environmental Maintenance: Keep meter installation environment dry & ventilated, avoid high temperature, humidity, dust and strong magnetic interference
  • Fault Handling: Cut off power to check wiring first after fault occurs, then test power supply, finally troubleshoot communication & chips; replace same-type meter if unreparable

12.2 Energy Consumption Meter Faults & Maintenance

Common Faults

  1. No reading / zero metering: Meter blockage, damaged sensor, power supply failure, wrong wiring
  2. Abnormal fluctuating data: Pipeline vibration, unstable water/gas flow, sensor drift, communication fault
  3. Water/gas leakage: Aged meter sealing parts, loose joints, damaged meter body
  4. Tamper alarm triggered: Meter opened, disassembled or data tampered artificially

Maintenance Rules

  • Daily Inspection: Check water/gas leakage, loose joints and display monthly, record metering data
  • Semi-annual Cleaning: Clean filter screens of water/heat meters every six months to prevent impurity blockage
  • Sensor Maintenance: Calibrate sensor precision annually, check loose/aged sensor wiring
  • Sealing Maintenance: Replace meter sealing parts every two years to prevent aging leakage
  • Fault Handling: Disassemble & clean filter screens for blockage, replace same-type sensors for sensor faults, replace meter body for damaged housings

12.3 Collection & Transmission Equipment Faults & Maintenance

Common Faults

  1. Offline gateway / no power supply: Power supply failure, loose power wire, damaged internal gateway power module
  2. Failed data collection: Mismatched communication protocols, conflicting terminal addresses, faulty RS485/Ethernet lines, damaged gateway ports
  3. Data loss / discontinuous transmission: Unstable network, full gateway cache, abnormal breakpoint resume function
  4. Disconnected switch port: Faulty network cable, damaged port, wrong VLAN configuration

Maintenance Rules

  • Daily Inspection: Check indicator light status, loose wiring and equipment overheating monthly
  • Quarterly Restart: Power off & restart gateways & switches every quarter to clear cache and restore system stability
  • Communication Maintenance: Inspect aging/damaged network & RS485 lines quarterly, test communication quality and optimize network configuration
  • Annual Firmware Upgrade: Upgrade gateway & switch firmware every year to fix vulnerabilities and improve equipment performance
  • Fault Handling: Check power supply & wiring for offline gateways; troubleshoot protocols, addresses and lines for failed data collection; replace network cables or ports for disconnected switch ports

12.4 Sensing Equipment Faults & Maintenance

Common Faults

  1. No data / zero reading: Power supply failure, wrong wiring, damaged internal sensor chip
  2. Drifted/large error data: Sensor precision drift, environmental interference, improper installation position
  3. Unupdated data: Faulty communication line, conflicting sensor address, wrong transmission protocol

Maintenance Rules

  • Daily Inspection: Check correct installation position, loose wiring and normal data display monthly
  • Semi-annual Calibration: Calibrate sensor precision every six months to ensure error within allowable range
  • Environmental Maintenance: Avoid installing sensors in high temperature, humid, strong magnetic and dusty areas, keep installation position ventilated & dry
  • Fault Handling: Check power supply & wiring for no data; recalibrate or replace sensors for drifted data; troubleshoot communication lines & addresses for unupdated data

12.5 Software Platform Faults & Maintenance

Common Faults

  1. Unaccessible platform: Server power failure, network fault, unstarted software service, insufficient account authority
  2. Blank/unshown data: Unstarted collection service, failed database connection, unsynchronized data
  3. Failed report export: Wrong report template, insufficient authority, insufficient server disk space
  4. Unsent alarms: Wrong alarm configuration, faulty SMS/APP service, disconnected network

Maintenance Rules

  • Daily Inspection: Check server operating status, normal software service & stable database connection daily
  • Daily Data Backup: Automatic daily database backup, manual weekly backup to prevent data loss
  • Monthly Disk Maintenance: Clean server disk junk files monthly, check disk space to avoid shortage
  • Annual Software Upgrade: Upgrade platform version every year to fix vulnerabilities and add new functions
  • Fault Handling: Check server & network for unaccessible platform; troubleshoot collection service & database for blank data; check templates & disk space for failed report export

12.6 Overall System Maintenance Cycle Table

Maintenance ObjectCycleMaintenance ContentResponsible Person
Smart Electricity Meters & InstrumentsMonthly inspection, annual calibrationAppearance inspection, wiring tightening, precision calibrationOperation & Maintenance Engineer
Energy Consumption MetersMonthly inspection, semi-annual cleaning, bi-annual sealing replacementLeakage inspection, filter screen cleaning, sealing part replacementOperation & Maintenance Engineer
Collection & Transmission EquipmentMonthly inspection, quarterly restart, annual firmware upgradeIndicator light inspection, wiring tightening, cache clearing, firmware upgradeOperation & Maintenance Engineer
Sensing EquipmentMonthly inspection, semi-annual calibrationInstallation position inspection, wiring tightening, precision calibrationOperation & Maintenance Engineer
Software PlatformDaily inspection, daily backup, monthly disk cleaning, annual upgradeServer status check, data backup, disk cleaning, software upgradeSystem Administrator

13. Factory Strength & After-sales Service

13.1 Factory Strength

KITOZER (Guangzhou Kaituozhe) is a high-tech enterprise specializing in building intelligent integration and energy conservation monitoring, focusing on R&D, production, sales and service of building energy conservation monitoring systems, computer room environment monitoring systems and industrial automation control systems. The factory is located in Baiyun District, Guangzhou, with a modern production base, professional R&D team and complete quality control system.

  • Production Scale: Factory covers 12,000 ㎡, equipped with 5 automatic production lines, annual capacity of 500,000 sets of equipment. Monthly output of core products (electricity meters, water meters, gateways, sensors) reaches 50,000 sets, meeting bulk supply demands of all large-scale projects.
  • R&D Strength: R&D team of over 50 personnel including 15 senior engineers and 20 software engineers; core technical staff with over 10 years of industry experience. Annual R&D investment accounts for 15% of revenue, holding more than 20 invention patents, 30 utility model patents and over 10 software copyrights with leading industry technical level.
  • Quality Control: Strictly implements ISO9001 Quality Management System, ISO14001 Environmental Management System and ISO45001 Occupational Health & Safety Management System. All products pass CE, FCC and CCC certifications, undergo 72-hour aging test, high-low temperature test and EMC test before delivery to guarantee stable & reliable product quality with 99.9% pass rate.
  • Supply Chain Advantages: Long-term strategic cooperation with well-known domestic & foreign component suppliers (TI, Huawei, ZTE). Direct supply of core components reduces production costs and guarantees product quality & delivery cycle.
  • Engineering Cases: 15 years of industry experience, serving over 1,000 customers covering government, real estate, commercial, industrial and data center fields, completing more than 2,000 engineering cases across 30 provinces & municipalities nationwide; products exported to Southeast Asia, Middle East, Africa and other regions with prominent brand influence.

13.2 After-sales Service

Adhering to the philosophy of “Customer First, Service Supreme”, KITOZER builds a 7×24h full-process after-sales service system to provide customers with one-stop services including scheme design, product selection, installation & commissioning, technical training and post-operation maintenance, guaranteeing long-term stable system operation.

(1) Warranty Commitment

  • Hardware Products: 3-year free warranty for all hardware (electricity meters, water meters, gateways, sensors, switches, etc.). Free repair & replacement of non-artificial damaged parts within warranty period, cost-price repair for lifetime after warranty.
  • Software Platform: 5-year free upgrade & lifetime technical support for software platforms; free vulnerability repair, new module addition and system performance optimization within warranty period.
  • Construction Works: 2-year free warranty for project construction, free handling of construction quality problems, line faults and equipment installation & commissioning issues within warranty period.

(2) Technical Support Services

  • 7×24h Hotline Support: National unified 400 service hotline available 7×24h for consultation, repair and complaint handling; response within 15 mins and solution provided within 30 mins.
  • Remote Technical Support: Remote commissioning, fault troubleshooting and technical guidance via phone, WeChat, QQ and remote desktop; simple faults resolved within 1 hour.
  • On-site Technical Support: Professional engineers dispatched to site within 24 hours for complex faults unsolvable remotely (4 hours for domestic first-tier cities, 8 hours for second-tier, 12 hours for third-tier); on-site troubleshooting, repair and commissioning until full system recovery.
  • Technical Training Service: 2 free on-site technical training sessions after project delivery (system operation, equipment maintenance, fault troubleshooting) with training manuals provided to ensure customer operation & maintenance personnel master system operation & maintenance skills proficiently; online video & document training available for technical inquiries anytime.

(3) Value-added Services

  • Regular Return Visit: Monthly phone return visit & quarterly on-site return visit after project delivery to understand system operation status & customer demands, discover and resolve potential problems timely.
  • Annual Free System Inspection: 2 full free system inspections per year (hardware, software platform & communication network), inspection report issued with optimization suggestions provided.
  • Customized Service: Customized functions, scheme optimization, equipment upgrade and data docking services according to customer demands.
  • Spare Parts Service: Spare parts list provided for large projects; core products stocked for fast replacement during emergency faults to shorten downtime.

14. Conclusion

As a core component of intelligent building integration, the building energy conservation monitoring system is a key technical means to realize refined energy management of buildings, reduce operation costs, accelerate green low-carbon transformation and implement carbon peaking & carbon neutrality goals. Featuring full independent R&D, high-precision metering, strong stability, easy deployment, low cost and intelligent management, the KITOZER building energy conservation monitoring system covers full scenarios including public buildings, industrial buildings, data centers and small buildings, providing customized one-stop energy conservation monitoring solutions for customers.

In the future, KITOZER will continue to deepen the building energy conservation & intelligent field, increase R&D investment, innovate technical products, optimize solutions and upgrade service quality. Driven by technological innovation to boost energy-saving upgrading and empowered by high-quality services to realize customer value, we will help more buildings achieve efficient energy conservation, intelligent management and green development, contributing to China’s building energy conservation industry and carbon peaking & carbon neutrality goals.

15. SEO Optimization (Keywords & Tag System)

15.1 Search Keywords

Core Primary Keywords

Building energy conservation monitoring system, KITOZER building energy conservation monitoring system, building energy consumption monitoring system, intelligent building integrated energy monitoring

High-conversion Long-tail Keywords

Public building energy conservation monitoring solution, factory energy consumption monitoring system, data center PUE monitoring system, small building energy monitoring equipment, KITOZER energy monitoring software, building sub-item energy consumption monitoring system, building energy data collection gateway, multi-functional power meter manufacturer

Industry Traffic Keywords

Building energy management platform, green building energy monitoring, building energy conservation under dual carbon goals, building energy consumption data analysis, building energy-saving renovation monitoring system, IoT energy consumption monitoring system, smart building energy management, building energy metering equipment

Brand Exclusive Keywords

KITOZER energy conservation monitoring system, KITOZER energy collection equipment, KITOZER multi-functional electricity meter, KITOZER data collection gateway, KITOZER energy monitoring software, Guangzhou Kaituozhe energy monitoring

Drop-down & Related Search Keywords

Price of building energy conservation monitoring system, manufacturer of building energy monitoring system, principle of building energy consumption monitoring system, composition of building energy monitoring system, building energy monitoring cases, functions of building energy monitoring software, industrial energy consumption monitoring solution, data center energy monitoring equipment

15.2 SEO Optimization Tag System

Core Page Optimization Tag

Building Energy Conservation Monitoring System_Building Energy Consumption Monitoring Solution_KITOZER Manufacturer

Title Tag

Building Energy Conservation Monitoring System-KITOZER Building Energy Consumption Monitoring Solution-Special for Public Buildings, Industrial Plants & Data Centers

Meta Keywords Tag

Building energy conservation monitoring system, building energy consumption monitoring system, KITOZER, intelligent building integration, public building energy monitoring, factory energy monitoring, data center PUE monitoring, energy collection equipment, energy monitoring software

Meta Description Tag

KITOZER specializes in intelligent building integrated energy conservation monitoring, providing full-scenario energy monitoring solutions for public buildings, industrial plants and data centers, covering energy collection, data transmission, data analysis & energy-saving control, high precision & stability, easy deployment, direct supply from manufacturer, 3-year warranty & 7×24h service.

H1 Tag

KITOZER Building Energy Conservation Monitoring System Solution

H2 Tags

System Overview, System Composition, System Classification, System Schematic Principle, System Configuration List, Product Technical Parameters, Product Application Scope, Product Advantages, Bid-winning Technical Parameters, Product Solutions, Application Cases, Product Faults & Maintenance, Factory Strength & After-sales Service, Conclusion

Internal Link Optimization Anchor Texts

  • Core Anchors: Building energy conservation monitoring system, building energy consumption monitoring system, KITOZER
  • Long-tail Anchors: Public building energy conservation monitoring, factory energy consumption monitoring, data center PUE monitoring, energy collection gateway, multi-functional power meter
  • Related Anchors: Intelligent building integration, green building, dual carbon goals, energy management platform, energy-saving renovation

15.3 Natural SEO Embedding in Main Text

Core keywords, long-tail keywords, brand keywords and related anchor texts are naturally embedded in each chapter without rigid stacking, complying with search engine optimization rules to boost page search ranking & exposure. Examples:

  • System Overview chapter embeds “The building energy conservation monitoring system is a core subsystem of intelligent building integration”
  • System Composition chapter embeds “The KITOZER building energy consumption monitoring system consists of perception layer, transmission layer, platform layer and application layer”
  • Application Cases chapter embeds “The KITOZER building energy conservation monitoring system helps office buildings cut energy consumption by 22%”
  • Product Advantages chapter embeds “KITOZER building energy monitoring equipment features high precision, high stability and full independent R&D”
Scroll to Top