KITOZER Bus Duct: 1600A Compact Sandwich Busway For Data Center

KITOZER 1600A compact sandwich bus duct is a prefabricated electrical distribution system that carries high current between switchgear, transformers, and power distribution units. The sandwich design packs copper conductors close together with thin insulation layers, resulting in a compact, low impedance busway suitable for data centers, high rise buildings, and industrial plants where cable trays would be too bulky. Busway is the modern alternative to heavy cable runs, offering lower losses, easier expansion, and tap off points along the route.

Product Overview

The bus duct consists of aluminum or copper conductors insulated with Mylar or DMD film, stacked compactly in an aluminum enclosure. Conductor joints use bolted or plug-in connections with silver plated contacts. Standard lengths of 2 to 3 meters are assembled with flexible expansion segments to absorb thermal movement. Tap off boxes can be mounted at intervals along the busway to feed branch circuits. The enclosure provides IP54 protection against dust and water spray. Each straight section is factory tested for high voltage and insulation resistance before shipment, and sections are numbered so installers can reassemble them in the correct order on site.

Technical Specifications

Rated voltage 690V, rated frequency 50/60Hz, rated current 1600A, rated short-time withstand 50kA for 1s, peak withstand 105kA. Conductor material aluminum or copper, tin or silver plated. Insulation class F, temperature rise 100K. Protection IP54 standard, IP66 optional. Standard straight section 2 meters, elbow and tee pieces available. Tap off box rating up to 400A. The voltage drop per meter is below 0.02 percent at rated current, and power loss per meter is around 0.8kW at full load. Compliance with IEC 61439-6 and GB 7251.2. The enclosure doubles as the protective earth conductor, so no separate earth path is needed along the run.

Applications

This bus duct is used to connect transformer to LV switchboard in data centers, to distribute power along long rows of server racks, and to feed large motor control centers in industrial plants. It is also used in high rise buildings to carry power from the basement transformer to upper floor distribution panels, and in convention centers and stadiums where temporary or permanent tap off points are needed. The compact profile fits in cable trays and raised floors where heavy cables would not. In data centers, tap off boxes every 3 meters feed individual server rack power distribution units, allowing IT teams to add or remove racks without touching the main bus.

Advantages

Sandwich construction minimizes skin effect and inductance, giving lower losses than cable. Tap off boxes allow branch circuits to be added without shutting down the bus. Factory assembled sections reduce on site labor and quality risk. Aluminum enclosure is light, corrosion resistant, and doubles as earth path. IP54 rating suits dusty industrial environments. Expansion joints absorb thermal movement. The busway has a 30 year service life and requires almost no maintenance. Because tap off points are built in, future expansion costs are a fraction of cable based distribution, which is a major advantage in growing data centers.

Installation and Maintenance

Support straight sections every 1.5 meters on hanging rods or floor stands. Assemble joints with the specified torque and apply contact compound. Use expansion segments at regular intervals and where the busway crosses building joints. Commissioning includes insulation resistance and joint resistance measurement. Maintain annually by inspecting enclosures for corrosion, checking joint torque on a sample of joints, and verifying tap off box door seals. Keep spare tap off boxes and joint plates on hand. Never open the live busway enclosure without an approved lock out procedure. After a fault, inspect the affected joint for arcing marks and measure contact resistance before re-energization.

Busway joints are the most likely point of failure, so every joint must be torqued to the exact value specified by the manufacturer and marked with a torque paint line. During preventive maintenance, inspect a sample of joints with a thermal camera under full load; any joint more than 10 degrees above ambient indicates a problem. Tap off boxes should be checked for door seal integrity, especially in dusty or washdown areas. When extending the busway, use only factory joint kits and never improvise with generic bolts. Keep the enclosure continuously bonded to the earthing system at both ends and at every expansion joint.

Ordering and Support

Ordering requires the single line diagram, route layout, tap off box positions, and support spacing. KITOZER supplies the bus duct with factory test reports, installation drawings, and a joint torque specification. Spare joint plates, tap off boxes, and expansion segments are recommended. Technical support covers route layout review, thermal expansion calculation, and site supervision. The busway is backed by a one year on site warranty and a ten year warranty on the enclosure against corrosion.

Price

From $280/meter. Contact +86 13922289957 for bus duct pricing.