KITOZER Busbar: 160A Rack Mount Busway For Edge Computing

Product Overview

KITOZER 160A rack mount busbar is a modular power distribution busway designed for edge computing rooms, network closets, and small server halls where traditional cable distribution becomes slow and inflexible. The system uses a fully insulated copper conductor enclosed in a steel trunking, delivering 160A continuously at 230V single phase or 400V three phase. Tap-off units can be plugged in and out while the busbar is energized, allowing technicians to add or remove rack power feeds without shutting down the distribution line. Compared with cable-and-duct wiring, the KITOZER 160A busbar reduces installation time, improves safety with finger-safe contacts, and gives facility teams full visibility over where power is being consumed.

The design philosophy behind this busbar is simple: make power distribution as modular as the IT equipment it feeds. A server rack can be added, moved, or removed in hours, but a cable-based power feed often requires a scheduled shutdown, a licensed electrician, and several meters of new conductor. The plug-in busway removes those barriers. Once the trunking is installed, every rack position is ready for service, and tap-off units can be swapped in minutes. This agility is especially valuable in edge locations where space is tight, maintenance windows are short, and load profiles change as new services are deployed.

Technical Specifications

The rated current is 160A at 400V three phase with copper conductor cross-section sized to keep temperature rise below 50K under full load. Standard busbar sections are 1.5 meters long and can be joined with plug-in joints to build any run length up to 40 meters. Tap-off units are available in 16A, 32A, and 63A ratings with CEE sockets or direct cable glands. Insulation class is F, protection rating IP20 on the trunking and IP44 on tap-off boxes. The busbar carries CE and IEC 61439-2 certification, short-time withstand current 15kA for 1 second, and peak withstand current 30kA. Mounting accessories include wall brackets, ceiling hangers, and rack-end feed units. Optional accessories include LED occupancy strip, local ammeter, and Modbus tap-off monitoring module.

Voltage drop along a 30 meter run at full load is below 2 percent, ensuring that racks at the far end of the row receive stable voltage. The conductor is tin-plated electrolytic copper with 99.9 percent purity, and the insulation is cross-linked polyolefin rated for 120 degrees Celsius. Joint resistance is controlled to below 10 micro-ohm per joint, and each joint is factory tested before shipment. The trunking body is formed from 1.5mm galvanized steel with a powder coat finish that resists scratches and corrosion. Tap-off units include an integrated MCCB or NH fuse rated to the socket key, providing downstream protection that coordinates with upstream breakers.

Application Scenarios

The 160A busbar is most commonly deployed along the rear or side of cabinet rows in edge data centers, colocation cages, and telecom equipment rooms. It feeds small UPS systems, server racks, network switches, and storage enclosures. It is also a good fit for retail back offices, bank branch server rooms, and industrial control rooms where load changes are frequent. In retrofit projects, the slim trunking fits into existing cable tray spaces and avoids the cost of pulling new cables through conduits. Teams that plan to add cabinets over time prefer the plug-in tap-off model because each new rack can be connected in minutes without a power shutdown.

Specific use cases include edge nodes for content delivery networks, telecom central offices serving 5G radio equipment, and small medical imaging suites that cannot tolerate power interruptions. In manufacturing, the busbar feeds programmable logic controllers and human machine interface panels on production lines. In commercial buildings, it is used to distribute power to audiovisual racks in conference centers and broadcast rooms. Because the trunking is slim, it can be surface-mounted on walls or suspended from ceilings without major architectural changes.

Advantages and Features

The main advantage of the KITOZER 160A busbar is flexibility. Tap-off units are keyed so that only the correct rating can be inserted into a socket, preventing overload mistakes. The copper conductor is tin-plated to resist oxidation and maintain low contact resistance over decades of cycling. Each joint includes a torque-controlled bolt system and a visual inspection window so maintenance teams can verify tightness without disassembly. The trunking is formed from galvanized steel with powder-coated finish, providing mechanical protection and electromagnetic shielding. Because the conductor is fully insulated, technicians can work near energized sections without arc-flash concerns when the correct PPE is used.

Additional features include a flame-retardant insulation coating that limits fire spread to 0.5 meters per IEC 60332-1. Tap-off units include a local LED that indicates energized state and a mechanical interlock that prevents withdrawal under load. The Modbus tap-off monitoring module reports current per socket to a central dashboard, enabling demand response and load balancing. Compared with traditional cable, the busway occupies roughly 40 percent less floor-to-ceiling space and reduces copper weight by half. It is also easier to expand: adding a section means clipping a new length onto the existing joint rather than pulling hundreds of meters of cable.

Installation and Maintenance Recommendations

Installation begins with mounting brackets at 1.2 meter intervals, keeping the trunking level and clear of hot-air exhaust paths. Joints must be tightened to the torque specified in the manual, and each joint should be torque-checked after 24 hours of energized operation. Tap-off units must be inserted with the integrated interlock handle, which isolates contacts before the unit can be withdrawn. Routine maintenance includes annual visual inspection of joints, infrared thermography under load, and cleaning of tap-off contacts with contact enhancer. Operators should keep spare tap-off units on site to replace damaged sockets within the same business day. Cable entries at the UPS end must be sized to the rated current and protected by upstream breakers coordinated with the busbar short-time rating.

For safe and reliable operation, maintain a clearance of at least 50mm above and below the trunking for ventilation. Do not route the busbar through walls without a fire-rated penetration seal. During commissioning, perform an insulation resistance test at 1000V DC before energization, and record the value in the as-built documentation. Train two on-site staff on tap-off insertion and withdrawal so that maintenance is not dependent on a single person. Update the CAD drawing whenever a tap-off is added or moved, so that future technicians always work from accurate information. KITOZER provides a detailed layout drawing service before shipment, ensuring that the correct number of feed-in and elbow units arrive on site.

Price

From $480 per meter including standard tap-off units. Contact +86 13922289957 for a full busway quotation with layout drawings and factory lead time.