ToggleProduct Overview
KITOZER 250A three phase busbar is engineered for medium data center power distribution along cabinet rows. It carries 250A continuously at 400V three phase, feeding dual-cord servers, storage arrays, and network switches through plug-in tap-off boxes mounted at each rack position. The system replaces traditional heavy cable runs between UPS output and rack PDU inputs, reducing conductor size, lowering copper cost, and shortening commissioning time. Because tap-off units can be added or relocated while the busbar is live, colocation providers and in-house data center teams can rebalance power among cabinets without scheduling downtime windows.
As rack densities rise from 4kW to 8kW and beyond, cable-based distribution becomes a bottleneck. A single 250A trunking can feed 20 to 30 racks, whereas cable runs of equivalent capacity occupy multiple cable trays and require careful phase balancing. The KITOZER 250A busbar solves this by pre-balancing phases at the factory and allowing tap-off boxes to be positioned exactly where the racks are. Live tapping means that a new cabinet can be brought online in the same week it arrives, rather than waiting for the next maintenance window.
Technical Specifications
Rated current 250A at 400V three phase 50/60Hz, copper conductor with cross-section selected for 40K temperature rise. Standard section length 2 meters, joint system with insulated cover and visible torque indicator. Tap-off units available in 16A, 32A, 63A, and 125A ratings, each with integrated MCCB or fuse protection. Protection rating IP20 on trunking, IP44 on tap-off enclosures. Short-time withstand current 25kA for 1 second, peak 50kA. Insulation class F, fire rating according to IEC 60332-1. CE and IEC 61439-2 certified. Optional tap-off monitoring module measures current per socket and reports over Modbus TCP to DCIM platforms. Trunking finish is RAL 9005 powder-coated galvanized steel.
Voltage drop is held below 3 percent over a 40 meter run at full load. The conductor is high-concentration copper with tin plating, and the insulation is silicone-free cross-linked polyolefin rated for 130 degrees Celsius. Joints use bolted pressure contacts with a torque marker that turns red if the bolt is loosened, giving maintenance staff an immediate visual cue. Tap-off boxes include a 50mm cable gland entry and a strain relief clamp. The trunking body is 2mm steel, and the cover is removable without tools for inspection. Operating temperature range is minus 25 to plus 55 degrees Celsius, and storage humidity is up to 95 percent non-condensing.
Application Scenarios
The 250A busbar is typically installed at the rear of server rows, 2.5 to 3 meters above the floor, feeding each rack through a short cable drop to the rack PDU. It is well suited for corporate data centers, cloud point-of-presence rooms, and colocation halls with mixed rack densities. In high-density AI and GPU training rooms, the busbar supports flexible repositioning of racks as projects scale. It is also used in healthcare imaging suites, broadcast production rooms, and industrial automation lines where uptime is critical and load profiles change quarterly.
Colocation providers favor this busbar because it allows them to deliver dedicated power to each cage without running separate conduits. Enterprise IT teams use it to consolidate UPS output feeds into a single row backbone, reducing the number of large breakers in the UPS output cabinet. In education and research facilities, the busbar supports labs that reconfigure equipment every semester. In government and defense facilities, the fully insulated trunking reduces touch-current risk in shared corridors. The modular design also makes it easy to decommission and relocate a row when the IT layout changes.
Advantages and Features
Key features include keyed tap-off sockets that prevent mis-rating, a flame-retardant insulation coating that limits fire spread, and joint covers that can be opened without removing the trunking. The system is compact, taking roughly half the space of equivalent cable tray. Because conductors are copper rather than aluminum, voltage drop is low and power losses are minimized over long row runs. Each tap-off unit includes a local indication LED and a test button for maintenance. With Modbus tap-off monitoring, operators see per-socket current in real time and receive alarms before overloads occur.
The busbar is also designed for safety and maintainability. Every joint is touch-safe under normal operation, and the trunking cover can be removed only with a tool, preventing accidental contact. Tap-off boxes include an emergency stop button and a mechanical flag that shows breaker position. The system supports hot-swap replacement of a tap-off unit in under two minutes, with no tools beyond the interlock handle. KITOZER provides as-built CAD drawings and a tap-off position log with every shipment, so the facility team starts with accurate documentation.
Installation and Maintenance Recommendations
Plan the layout so that feed-in points are near the UPS output cabinet and runs stay under 30 meters to control voltage drop. Use the correct hanger brackets for the ceiling structure and include expansion joints every 20 meters to absorb thermal movement. When inserting tap-off units, verify that the upstream breaker rating matches the socket key. Perform an infrared scan after 72 hours of full load to confirm joint temperatures are within limits. Annual maintenance includes tightening joint bolts to specified torque, cleaning tap-off contacts, and replacing any sockets with discolored insulators. Keep a log of tap-off positions so that future moves can be coordinated with the as-built drawing.
During installation, ensure that the trunking is grounded at both ends and that the earth conductor is at least half the cross-section of the phase conductor. Do not paint over joint covers, as this masks the torque indicator. When extending a run, use only KITOZER original joint kits to maintain warranty. Commissioning includes a phase rotation check, an insulation resistance test at 1000V, and a load balance measurement across all three phases. KITOZER offers factory training for facility teams on safe tap-off insertion and withdrawal.
Price
From $680 per meter including 63A tap-off units. Contact +86 13922289957 for project pricing with layout services.