Table of Contents
ToggleProduct Overview
KITOZER 250A three phase busbar is engineered for medium data center power distribution along cabinet rows. It carries 250A continuously at 400V three phase, feeding dual-cord servers, storage arrays, and network switches through plug-in tap-off boxes mounted at each rack position. The system replaces traditional heavy cable runs between UPS output and rack PDU inputs, reducing conductor size, lowering copper cost, and shortening commissioning time. Because tap-off units can be added or relocated while the busbar is live, colocation providers and in-house data center teams can rebalance power among cabinets without scheduling downtime windows.
Technical Specifications
Rated current 250A at 400V three phase 50/60Hz, copper conductor with cross-section selected for 40K temperature rise. Standard section length 2 meters, joint system with insulated cover and visible torque indicator. Tap-off units available in 16A, 32A, 63A, and 125A ratings, each with integrated MCCB or fuse protection. Protection rating IP20 on trunking, IP44 on tap-off enclosures. Short-time withstand current 25kA for 1 second, peak 50kA. Insulation class F, fire rating according to IEC 60332-1. CE and IEC 61439-2 certified. Optional tap-off monitoring module measures current per socket and reports over Modbus TCP to DCIM platforms. Trunking finish is RAL 9005 powder-coated galvanized steel.
Application Scenarios
The 250A busbar is typically installed at the rear of server rows, 2.5 to 3 meters above the floor, feeding each rack through a short cable drop to the rack PDU. It is well suited for corporate data centers, cloud point-of-presence rooms, and colocation halls with mixed rack densities. In high-density AI and GPU training rooms, the busbar supports flexible repositioning of racks as projects scale. It is also used in healthcare imaging suites, broadcast production rooms, and industrial automation lines where uptime is critical and load profiles change quarterly.
Advantages and Features
Key features include keyed tap-off sockets that prevent mis-rating, a flame-retardant insulation coating that limits fire spread, and joint covers that can be opened without removing the trunking. The system is compact, taking roughly half the space of equivalent cable tray. Because conductors are copper rather than aluminum, voltage drop is low and power losses are minimized over long row runs. Each tap-off unit includes a local indication LED and a test button for maintenance. With Modbus tap-off monitoring, operators see per-socket current in real time and receive alarms before overloads occur.
Installation and Maintenance Recommendations
Plan the layout so that feed-in points are near the UPS output cabinet and runs stay under 30 meters to control voltage drop. Use the correct hanger brackets for the ceiling structure and include expansion joints every 20 meters to absorb thermal movement. When inserting tap-off units, verify that the upstream breaker rating matches the socket key. Perform an infrared scan after 72 hours of full load to confirm joint temperatures are within limits. Annual maintenance includes tightening joint bolts to specified torque, cleaning tap-off contacts, and replacing any sockets with discolored insulators. Keep a log of tap-off positions so that future moves can be coordinated with the as-built drawing.
Price
From $680 per meter including 63A tap-off units. Contact +86 13922289957 for project pricing with layout services.