KITOZER 400A data center busway is a medium-capacity enclosed busbar used to distribute power from UPS output switchgear to multiple cabinet rows. At 400A per phase, it supports high-density rack populations of 8 to 12kW per cabinet and leaves headroom for future growth. The plug-in tap-off box design means that each rack connection can be added, moved, or changed without de-energizing the busway. This live-working capability is essential in data centers that cannot afford planned downtime for cabling changes.
Technical Specifications
Rated current 400A at 400V three phase, copper conductor sized for 35K temperature rise. Standard section 2 meters, with corner, tee, and feed-in units available. Tap-off boxes offered in 32A, 63A, 125A, and 250A ratings, each fitted with MCCB or NH fuse. Protection IP30 trunking, IP44 tap-off. Short-time withstand 35kA for 1 second, peak 70kA. Insulation class F, flame retardant insulation coating. CE and IEC 61439-2 certified. Optional tap-off monitoring with current, voltage, power, and breaker status per socket, reported via Modbus TCP or SNMP. Housing is galvanized steel with RAL 7035 finish. Busbar can be wall-mounted, ceiling-suspended, or floor-standing in trunking style.
Application Scenarios
Typical installations include enterprise data centers of 200 to 500 racks, colocation halls, and cloud on-premise rooms. The busway is fed from the UPS output cabinet and runs along one or both sides of the hot aisle, with tap-off boxes dropping to rack PDUs. It is also used to feed cooling units such as CRAH and chiller pumps, when those loads are on the same essential bus. Modular construction allows the busway to be extended in phases as capacity grows, avoiding the upfront cost of oversized cable.
Advantages and Features
The 400A rating gives designers the ability to power more racks from a single run, reducing the number of feed-in points and simplifying upstream coordination. Tap-off boxes are mechanically interlocked so that the downstream breaker must be open before the box can be withdrawn, protecting technicians. Each box includes a visible window into the breaker position and an emergency stop. The joint system uses bolted copper connections with insulating covers that are tool-free to remove. Low voltage drop along the run means that racks at the far end receive stable voltage even at peak load.
Installation and Maintenance Recommendations
Plan the run so that feed-in points balance the load across all three phases, and keep tap-off boxes within easy reach of maintenance staff. Use torque wrench on all joints and verify with infrared camera after load is applied. Because the busway carries essential power, maintenance should be scheduled during a window when redundant systems can take over. Annual inspection includes checking joint temperatures, tap-off contacts, and breaker operation. Keep spare tap-off boxes on site in the same ratings as the installed sockets. Document every change in a digital twin or CAD drawing so that future modifications start from accurate information.