ToggleProduct Overview
KITOZER 400A data center busway is a medium-capacity enclosed busbar used to distribute power from UPS output switchgear to multiple cabinet rows. At 400A per phase, it supports high-density rack populations of 8 to 12kW per cabinet and leaves headroom for future growth. The plug-in tap-off box design means that each rack connection can be added, moved, or changed without de-energizing the busway. This live-working capability is essential in data centers that cannot afford planned downtime for cabling changes.
The 400A rating sits between the compact 250A row busway and the heavy 630A main busway, making it a versatile choice for most enterprise data halls. It can serve as the primary backbone for a single hall or as a sub-bus fed from a larger main switchboard. Because tap-off boxes range from 32A to 250A, the same trunking can feed small network racks, medium server racks, and large cooling units without separate cabling. This flexibility simplifies both design and future expansion.
Technical Specifications
Rated current 400A at 400V three phase, copper conductor sized for 35K temperature rise. Standard section 2 meters, with corner, tee, and feed-in units available. Tap-off boxes offered in 32A, 63A, 125A, and 250A ratings, each fitted with MCCB or NH fuse. Protection IP30 trunking, IP44 tap-off. Short-time withstand 35kA for 1 second, peak 70kA. Insulation class F, flame retardant insulation coating. CE and IEC 61439-2 certified. Optional tap-off monitoring with current, voltage, power, and breaker status per socket, reported via Modbus TCP or SNMP. Housing is galvanized steel with RAL 7035 finish. Busbar can be wall-mounted, ceiling-suspended, or floor-standing in trunking style.
Voltage drop is controlled to below 2.5 percent over a 50 meter run. The conductor is tin-plated copper with a cross-section chosen to minimize skin effect losses at 50 and 60Hz. Insulation is cross-linked polyolefin rated for 130 degrees Celsius and self-extinguishing. Joints are bolted with insulated covers and include a visible torque indicator. Tap-off boxes include an integrated breaker with local trip indicator and a mechanical interlock that prevents withdrawal under load. The trunking body is 2.5mm steel, and covers are removable without tools. Operating temperature range minus 25 to plus 55 degrees Celsius.
Application Scenarios
Typical installations include enterprise data centers of 200 to 500 racks, colocation halls, and cloud on-premise rooms. The busway is fed from the UPS output cabinet and runs along one or both sides of the hot aisle, with tap-off boxes dropping to rack PDUs. It is also used to feed cooling units such as CRAH and chiller pumps, when those loads are on the same essential bus. Modular construction allows the busway to be extended in phases as capacity grows, avoiding the upfront cost of oversized cable.
In healthcare facilities, the busway feeds IT and medical equipment in shared essential power systems. In financial trading rooms, it supports high-density compute stacks that must be rebalanced as trading volumes change. In hyperscale edge facilities, multiple 400A busways run in parallel to serve thousands of racks. The system also suits industrial cleanrooms, semiconductor fabs, and automotive plants where power reliability directly affects production. Because the trunking is sealed against dust, it can be installed in semi-clean environments without additional protection.
Advantages and Features
The 400A rating gives designers the ability to power more racks from a single run, reducing the number of feed-in points and simplifying upstream coordination. Tap-off boxes are mechanically interlocked so that the downstream breaker must be open before the box can be withdrawn, protecting technicians. Each box includes a visible window into the breaker position and an emergency stop. The joint system uses bolted copper connections with insulating covers that are tool-free to remove. Low voltage drop along the run means that racks at the far end receive stable voltage even at peak load.
With optional tap-off monitoring, operators can measure load at each socket and balance phases remotely. The monitoring module reports data every second to a DCIM dashboard, and alarms are triggered when a socket exceeds 80 percent of its rating. This capability supports predictive maintenance and capacity planning. The busway is also designed for easy disassembly and relocation if a facility is reconfigured. KITOZER provides layout drawings, factory testing reports, and commissioning support with every project.
Installation and Maintenance Recommendations
Plan the run so that feed-in points balance the load across all three phases, and keep tap-off boxes within easy reach of maintenance staff. Use torque wrench on all joints and verify with infrared camera after load is applied. Because the busway carries essential power, maintenance should be scheduled during a window when redundant systems can take over. Annual inspection includes checking joint temperatures, tap-off contacts, and breaker operation. Keep spare tap-off boxes on site in the same ratings as the installed sockets. Document every change in a digital twin or CAD drawing so that future modifications start from accurate information.
During installation, maintain a minimum clearance of 300mm from combustible materials and follow local code for fire-rated penetrations. Ground the trunking at both ends and bond all joints with a separate earth strap. Commissioning includes a phase rotation check, an insulation resistance test at 1000V DC, and a full-load test to confirm voltage drop. KITOZER recommends an annual infrared scan under at least 60 percent load, and a torque check every two years. Keep a digital log of all tap-off positions and load values for future expansion planning.
Price
From $980 per meter including 125A tap-off boxes. Contact +86 13922289957 for detailed data center busway quotation.