Table of Contents
ToggleProduct Overview
KITOZER 630A high density modular busway is designed for large data centers, industrial plants, and commercial buildings where high current must be distributed with safety and flexibility. At 630A per phase, the busbar supports full data hall power demands including IT loads, air conditioning, and lighting. The modular system allows straight sections, elbows, tees, and feed-in units to be assembled on site without specialized tooling. Tap-off boxes up to 400A can be inserted while the busbar is energized, making the system ideal for phased commissioning and future expansion.
The 630A rating is commonly used as the main distribution backbone between the LV switchboard and sub-busways. It replaces oversized cable bus ducts that are expensive to fabricate and difficult to modify. With modular sections, a 100 meter run can be built from standard lengths, with corners and tees added as needed. This prefabricated approach reduces on-site labor by 50 percent compared with custom bus duct and shortens project schedules by weeks. It also improves quality, because every joint is factory tested rather than field fabricated.
Technical Specifications
Rated current 630A at 400V three phase, copper conductor with high-concentration alloy to limit skin effect losses. Standard straight section 2 meters, with horizontal and vertical elbows available. Tap-off boxes in 63A, 125A, 250A, and 400A ratings with MCCB or fuse protection. Protection IP30 trunking, IP44 tap-off. Short-time withstand 50kA for 1 second, peak 105kA. Insulation class F, flame retardant UL94 V0 coating. CE and IEC 61439-2 certified. Optional integrated current transformers per phase for metering, and Modbus TCP communication for upstream BMS. Housing is heavy-gauge galvanized steel with powder coat.
Voltage drop is below 3 percent over a 60 meter run at full load. The conductor is tin-plated copper with a cross-section selected for low AC resistance. Insulation is cross-linked polyolefin rated for 130 degrees Celsius and self-extinguishing. Joints are bolted with insulated covers and include a visible torque indicator. Tap-off boxes include an integrated breaker rated to the box size, with local trip indicator and mechanical interlock. The trunking body is 3mm steel, and covers are removable without tools. Operating temperature range minus 25 to plus 55 degrees Celsius. Weight per 2 meter section is approximately 45kg.
Application Scenarios
The 630A busway is commonly used as the main distribution backbone in hyperscale data centers, semiconductor cleanrooms, and large manufacturing plants. It feeds multiple sub-busways, UPS systems, and large motor control centers. In commercial high-rise buildings, it runs vertically through shafts to feed floor switchboards. Because tap-off boxes can be sized independently, a single run can serve both small loads (lighting, outlets) and large loads (chillers, UPS) without separate cabling.
In data centers, the 630A busway connects the LV switchboard to the UPS output switchgear, and then to row sub-busways. In industrial plants, it feeds large motor control centers and process heaters. In shopping malls and airports, vertical risers distribute power to each floor. In hospitals, it serves essential power systems in operating rooms and intensive care units. The system is also used in solar farms and battery storage installations where high DC or AC current must be routed safely.
Advantages and Features
The most visible benefit is space savings. A 630A busway occupies far less room than equivalent cable bundles in tray. The modular design reduces on-site fabrication, lowering installation labor and shortening project schedules. Joints are pressure-controlled with visible torque markers, and each joint is tested at the factory before shipment. Tap-off boxes include integrated isolation that meets arc-flash safety requirements. With optional metering, operators can measure load at each tap-off point and balance phases remotely. The system is also designed for easy disassembly and relocation if a facility is reconfigured.
Safety features include touch-safe covers, a flame-retardant insulation system, and short-circuit withstand ratings that exceed typical LV switchboard levels. The busway is designed to arc-flash category 2 for maintenance work, reducing PPE requirements. KITOZER provides coordination studies to ensure upstream breakers trip before the busway is damaged. The modular construction also means that a single section can be replaced without dismantling the entire run, reducing maintenance cost. Spare sections and tap-off boxes can be kept on site for fast response.
Installation and Maintenance Recommendations
Because of the high current rating, installation must follow a strict lifting and alignment procedure. Use the provided joint plates and torque bolts, and do not overtighten. Maintain required clearance from combustible materials and follow local electrical code for vertical shaft installations. After energization, perform a full infrared scan under at least 60 percent load. Routine maintenance includes thermography every six months, joint torque check every year, and tap-off contact cleaning every two years. Keep a digital log of all tap-off positions and load values so that future expansions can be planned without overloading existing sections.
During installation, use licensed electricians and follow the KITOZER lifting diagram. Support the trunking with brackets rated for the total weight, including the 2x safety factor. Ground the trunking at both ends and bond joints with earth straps. Commissioning includes a phase rotation check, an insulation resistance test at 2500V DC, and a full-load voltage drop measurement. KITOZER recommends annual thermography and a torque check every two years. Keep a digital copy of the as-built drawing and update it whenever tap-off positions change.
Price
From $1,580 per meter including 250A tap-off boxes. Contact +86 13922289957 for large project busway engineering support.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com