The KITOZER DN150 wafer type butterfly valve provides shutoff and isolation for chilled water, condenser water, and heating water piping. The compact wafer design fits between two standard flanges, reducing installation length and cost compared with flanged gate valves. It is available with lever handle, gear operator, or electric actuator for on off or modulating service.
Table of Contents
ToggleProduct Overview
The valve body is ductile iron with epoxy coating, the disc is stainless steel or nickel plated ductile iron, and the seat is EPDM or NBR. The stem is stainless steel with blowout proof design. Wafer body fits PN10 or PN16 flanges. The valve provides bubble tight shutoff per API 598. A visual position indicator shows open closed status. Larger sizes use gear operator for easy handwheel operation.
Technical Specifications
Nominal size DN150. Working pressure 16 bar. Temperature range minus 10 C to 120 C. Body ductile iron GGG50 epoxy coated. Disc SS316. Seat EPDM. Flange standard EN 1092 PN16. Weight 9 kg. Lever handle standard, gear option available. CE certified, 2 year warranty.
Application Scenarios
Use these valves as isolation valves on chiller, pump, and air handling unit connections, on cooling tower piping, and on domestic water systems. Wafer valves are also installed as balancing valves when paired with drain ports and pressure test points. Electric actuator versions provide automatic shutoff for fire safety, freeze protection, or BMS controlled isolation. The compact size makes them ideal for crowded mechanical rooms.
Advantages and Features
Wafer design is 70 percent shorter than flange end valves, saving space. Ductile iron body resists fracture better than cast iron. EPDM seat is rated for hot and cold water. Full port design minimizes pressure drop. The disc rotates 90 degrees for quick operation. Stainless stem prevents corrosion. Long service life with simple replacement seat. The valve can be installed in any orientation.
Installation and Maintenance
Install between flanges with full length bolts through the valve. Do not over tighten the flange bolts, as this deforms the body and increases operating torque. Use a torque wrench to flange manufacturer specification. Flush the system before first operation to avoid debris scoring the seat. Cycle the valve quarterly to prevent seizing. Inspect seat condition during shutdowns. Rebuild by replacing seat and disc after 10 years or when leakage exceeds allowable.
Price
From $95 per valve. Contact KITOZER for electric actuator and gear operator options.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com