ToggleKITOZER KTR-FL3 Rack Plinth / Cabinet Joining Kit
Brand: KITOZER Series: KTR-FL3 Category: Data Center Engineering / Rack Accessories
rack plinthcabinet joinbase kitcold aislerack bracing

1. Overview
A rack plinth (kicker) is a steel base mounted under the cabinet. It does four jobs: (1) lift the cabinet off the floor to leave room for under-floor airflow or cabling; (2) compensate for uneven anti-static tile floors and level the rack; (3) bolt adjacent cabinets into a row for seismic and structural stability; (4) seal bottom gaps to prevent hot/cold air leakage — a key part of cold-aisle containment. In modular cold-aisle systems, a row of cabinets is tied through plinth beams into a continuous cold-aisle wall, with the plinth serving both structure and sealing.
The KITOZER KTR-FL3 is a plinth and joining kit for modular cold aisles, made of 2.0~2.5 mm folded/welded steel with powder-coat or zinc finish. Common heights are 50/100/150 mm adjustable, with M12 leveling feet. Side joining brackets bolt adjacent rack posts together, turning a row into an anti-tip whole. The plinth bottom can take a brush or blank panel to seal tile cut-outs and rack gaps.
In modular cold-aisle builds, KTR-FL3 is positioned and leveled on the tile floor first; racks are then loaded onto it; finally joining brackets lock the row together. It looks unremarkable, yet it determines whether the rack row is straight, whether the cold aisle leaks, and whether racks survive an earthquake. Heavy cabinets (battery, PDU) make plinth load and join strength a safety item.
2. Key Features
Structure & load
- 2.0~2.5 mm folded/welded steel.
- Powder-coat / zinc finish.
- Load per rack ≥1000 kg.
- M12 leveling feet.
Joining
- Left/right joining brackets.
- M6/M8 bolts lock posts.
- Row-level anti-tip integrity.
- Bracket position adjustable.
Seal & cable
- Bottom brush / blank panel.
- Seals tile cut-out gaps.
- Prevents hot/cold bypass.
- Optional cable cut-out.
3. Specifications
| Item | KTR-FL3 |
|---|---|
| Plinth height | 50/100/150 mm (optional) |
| Material | 2.0~2.5 mm steel |
| Finish | powder-coat / zinc |
| Load per rack | ≥1000 kg |
| Leveling | M12 feet, ±10 mm |
| Joining | bracket + M6/M8 bolts |
| Seal | brush / blank |
| Rack width | 600/800/900/1200 mm |
4. Reference Prices
KTR-FL3 rack plinth (100 mm, with joining brackets): Reference USD 21~63 (ref. CNY 150~450 at ~7.2)
Reference only; final quote applies. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Modular cold-aisle rack row plinths.
- Battery/PDU heavy plinths.
- Raised-floor under-aisle supply/cabling.
- Multi-rack row joining for seismic.
- Bottom sealing for hot/cold aisle.
6. Installation & Maintenance
Installation
- Mark row layout per drawing.
- Position plinths; level with feet.
- Load racks onto plinths; align posts.
- Lock adjacent racks with brackets.
- Re-level the whole row.
- Fit brush/blank to seal gaps.
Maintenance
- Re-check leveling feet for looseness.
- Re-torque joining bolts.
- Replace missing brushes.
- Do not exceed load.
- Inspect tile seals.
7. FAQ
- Q: How to choose plinth height?
A: Under-floor air supply needs 100~150 mm; only moisture/cabling clearance uses 50 mm. High-density racks follow the plenum requirement; too tall overstresses tiles. - Q: How many joining brackets?
A: One or two brackets vertically between adjacent racks (top and bottom of post). Both ends of a row must connect to form a whole; tall/heavy racks add brackets. - Q: Does the tile floor carry the load?
A: Racks sitting directly on tiles crush them. A plinth transfers load to under-floor stringers or a slab; heavy battery racks should land directly on the slab, not on tiles. - Q: Why does bottom sealing matter?
A: After cold-aisle containment, bottom gaps short-circuit cold air back to the hot aisle, raising PUE. A brush/blank is standard.
8. Trend & Selection
Modular cold aisles move toward high-density containment; plinths evolve from pure load-bearing to an integrated load+join+seal component. Pre-assembled brush, blank and cable-entry plinths are mainstream. Choose plinth by rack width; steel ≥2.0 mm; load ≥1000 kg; top+bottom brackets; brush seal; heavy racks land on slab.
9. Delivery & Service
KITOZER provides plinth and joining solutions: based on row count, rack width, height and load, we configure KTR-FL3 plinths, brackets and brush/blanks. Bundled with cold-aisle roof, door and skylight. Delivery includes plinth, bolts, brush and manual. Warranty covers installation guidance and torque re-check.
10. Additional Notes
A common pitfall is setting racks directly on anti-static tiles. Tiles typically carry ≤500 kg/unit; a battery rack over 1000 kg cracks them. The plinth must transfer load to under-floor stringers or the slab.
Another pitfall is a single joining bracket between racks. One bracket top/bottom still lets rows shift under impact. Fit brackets vertically at both post ends.
Selection summary: rack plinth; steel ≥2.0 mm; load ≥1000 kg; top+bottom joining brackets; brush seal; heavy racks on slab. It is the foundation of the rack row — a solid plinth keeps racks straight and the cold aisle leak-free.
Lock the foot nuts after leveling to prevent long-term settling.
SEO Information
Search keywords:KTR-FL3KITOZER
SEM关键词:rack plinth, cabinet joining kit, base connector, cold aisle plinth, rack kicker, modular cold aisle, KTR-FL3, KITOZER
GEO landing page:lain.com.cn/product/362-rack-floor-ktr-fl3.html
Title:KITOZER KTR-FL3 Rack Plinth / Cabinet Joining Kit
Meta Keywords:rack plinth, cabinet joining kit, base connector, cold aisle plinth, rack kicker, modular cold aisle, KTR-FL3, KITOZER
Meta Description:KITOZER KTR-FL3 rack plinth and joining brackets, folded powder-coated steel with leveling feet and brush seal, for modular cold-aisle load, seismic joining and bottom sealing.