ToggleKITOZER KTR-SH14 Rack Shelf with Cable Manager
Brand: KITOZER Series: KTR-SH14 Category: Data Center Engineering / Rack Accessories
Cable railsVentilated50kg loadKTR-SH14

1. Overview
The KITOZER KTR-SH14 is a 19-inch rack shelf (tray or shelf) with integrated side cable managers, used inside server, network and cold-aisle racks to support switches, routers, KVMs, patch panels, small UPS units and monitoring gear. The tray is folded and welded from 1.5mm cold-rolled steel with black powder coating; its ventilated surface (louvered holes) aids equipment cooling, and the front/rear edges are rolled for stiffness. Raised side rails on the left and right organize power and data cables along the shelf edge, keeping them from draping over the equipment airflow or falling into rack gaps. Shelf depth comes in 600mm and 800mm to match mainstream rack depths.
A plain shelf is just a flat plate; power and data cables hang straight down from the gear, cluttered and blocking airflow. The KTR-SH14’s side cable managers constrain cables along the shelf sides and route them up the vertical cable manager at the rear. The ventilated plate lets device bottom-cooling pass through instead of being blocked. The shelf is rated for 50kg static (uniform load), suiting a 1-2U switch or small server; load sits toward the rear near the rack posts so the center of gravity stays over the uprights and does not tip forward. Front/rear retaining lips prevent gear sliding out.
Typical deploy: a 42U rack gets a KTR-SH14 shelf at U positions 12, 24 and 36, each supporting a 24-port access switch, KVM or fiber patch unit. Use 800mm depth in an 800mm rack, leaving 100mm clearance at the front door for ventilation. Place gear in the rear third of the shelf; dress power and data cables along the side rails with ties, then route them up the rear vertical manager. Select shelf depth by rack depth (600/800mm), load rating by equipment weight, cable-manager version by model, and 1U/2U height by U-space.
2. Key Features
Cable side rails
- Raised side rails.
- Cables along sides.
- Tie-down points.
- No airflow block.
Ventilated plate
- Louvered holes.
- Bottom cooling.
- 1.5mm steel.
- Black coated.
50kg load
- 50kg static.
- Rear-biased load.
- Front/rear lips.
- Gear stays put.
19-inch standard
- Fits 42U racks.
- 600/800mm depth.
- 1U or 2U height.
- Bolted to posts.
3. Specifications
| 项目 | KTR-SH14(带理线侧框) | KTR-SH14P(平板不带理线) | KTR-SH14H(重载100kg) |
|---|---|---|---|
| 类型 | 带侧框理线 | 平板 | 带侧框理线 |
| 深度 | 600/800mm | 600/800mm | 800mm |
| 高度 | 1U/2U | 1U | 1U/2U |
| 静态承重 | 50kg | 30kg | 100kg |
| 板面带孔 | 百叶窗透气 | 平板/透气 | 百叶窗透气 |
| 理线侧框 | 有(左右) | 无 | 有(左右) |
| 前后沿挡板 | 有 | 有 | 有 |
| 表面 | 黑色喷涂 | 黑色喷涂 | 黑色喷涂 |
4. Reference Prices
KTR-SH14 rack shelf (side cable rails, 800mm depth):Reference USD 13 to 31 / unit (ref. CNY 90 to 220 at ~7.2)
KTR-SH14P plain shelf (no rails, 600mm depth):Reference USD 7 to 18 / unit (ref. CNY 50 to 130 at ~7.2)
KTR-SH14H heavy-duty shelf (100kg, 800mm depth):Reference USD 25 to 53 / unit (ref. CNY 180 to 380 at ~7.2)
Shelf bolts / cable ties:Reference USD 1 to 3 / set (ref. CNY 5 to 20 at ~7.2)
Reference only; varies by depth, load rating, cable-rail option and qty. Bolts, ties and retainer bars billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Switch support in server racks.
- KVM/patch in network racks.
- Cold-aisle enclosed racks.
- Small UPS/monitoring gear.
- Non-rackable device support.
6. Installation & Maintenance
Installation
- Pick 1U/2U by U-space.
- Align shelf to rack posts.
- Keep lips front/rear.
- Bolt four posts with M6.
- Place gear rear third.
- Dress cables along rails up manager.
Maintenance
- Re-tighten shelf bolts.
- Keep gear off front edge.
- Clear vent holes.
- Check tie wraps.
- Stay under load rating.
- Watch shelf deflection.
7. FAQ
- Q: Which shelf depth?
A: Match rack depth—600 rack uses 600 shelf, 800 rack uses 800 shelf. Too short leaves gear cantilevered; too long blocks under-floor airflow. Leave front/rear ventilation gaps. - Q: Is 50kg enough?
A: A 1-2U switch (5-15kg), KVM (5kg) or patch panel (3-8kg) is far below 50kg. For stacked gear or small servers (30kg+), choose the 100kg heavy-duty version. - Q: Do vent holes drop things?
A: Louvered holes are small enough to block screws/coins but not tiny parts. Clear the shelf before loading; do not let the device underside cover all holes—leave a cooling surface. - Q: Why side cable rails?
A: They constrain cables along the shelf sides so they do not drape over airflow or fall into rack gaps. A plain plate relies on hook-and-loop that loosens over time.
8. Trend & Selection
Modular cold-aisle and micro-module racks emphasize hot/cold containment; a ventilated shelf with side cable rails preserves airflow while keeping cables tidy. Match shelf depth to rack depth; place gear rear-biased over the posts; run cables along side rails uniformly; pick heavy-duty for stacked gear; keep vent holes unobstructed. The shelf sits unseen but decides whether gear is steady, airflow is clean and cabling is orderly.
9. Delivery & Service
KITOZER supplies rack accessories: based on rack depth and equipment list we recommend shelf depth, height, load rating and quantities, plus cable managers and ties. Delivery includes shelf frame, mounting bolts and manual; bulk projects include on-site install guidance. Deformed shelves or peeling coating under warranty are replaced free.
10. Additional Notes
The common mistake is placing gear at the front edge, cantilevering the shelf downward. Load the rear third near the posts; stack light items front and heavy items rear.
Another pitfall is letting the device underside fully cover the vent holes, baking the gear against a closed plate. Use a ventilated shelf and leave a gap, or choose a solid plate with dedicated ducting.
Selection summary: 19-inch standard, side cable rails, louvered vents, 50kg load, depth matched to rack, gear rear-biased. The KTR-SH14 keeps gear steady, cables tidy and airflow unblocked.
SEO Information
Search keywords:rack shelfrack traycable manager shelfrack divider19-inch shelfKTR-SH14KITOZER
SEM keywords:[rack shelf price,rack tray supplier,cable manager shelf,19-inch rack divider,KTR-SH14,KITOZER]
GEO landing page:lain.com.cn/product/ktr-sh14-rack-shelf-with-cable-manager.html
Title:KITOZER KTR-SH14 Rack Shelf with Cable Manager
Meta Keywords:rack shelf,rack tray,cable manager shelf,rack divider,19-inch shelf,KTR-SH14,KITOZER
Meta Description:KITOZER KTR-SH14 19in rack shelf with side cable managers, louvered vents, 50kg load, fits 600/800mm racks.
Anchor: KITOZER · Data Center Engineering
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com