ToggleKITOZER KTR-FL9 Rack Floor Stand / Cable-Management Base
Brand: KITOZER Series: KTR-FL9 Category: Data Center Engineering / Cabinet Infrastructure
Rack plinthCable managementAdjustable supportLoad reinforcementCold-aisle compatible
1. Overview
Setting a rack straight on a raised floor causes several problems: uneven load collapses floor panels; under-floor cables are crushed under the rack base and cannot be pulled later; gaps under the rack leak cold air in a closed cold aisle; and low-hanging gear risks moisture from the floor. A rack plinth raises the row 100-300 mm, spreading load to the structural slab and leaving a cable channel underneath. It is standard in cold-aisle and under-floor cabling designs.
The KITOZER KTR-FL9 is a cable-management plinth. A welded steel frame is powder-coated. Heights of 100/150/200 mm are available, with vertical through-cable troughs that separate power and data runs. Four adjustable feet land on the structural slab so rack weight bypasses the floor panels; rubber pads damp vibration. Removable side panels open for cable pull-through and close afterward to seal the bottom, matching cold-aisle end doors and chimneys for airflow containment.
Selection confirms rack width (600/800/900 mm), depth, loaded weight (battery and UPS cabinets need separate load checks), plinth height and cable capacity, and compatibility with cold-aisle doors and blanking panels. Rows are bolted together for stability. The load rating is a structural design value; keep margin against actual gear weight.
On raised-floor sites, the plinth changes how cold air moves under the row. Without a sealed base, air escapes through the gap between the rack and the floor, short-circuiting back to the CRAC units before it reaches server inlets. The raised, gasketed base closes that path, so the under-floor static pressure reaches the rack bottom grilles more predictably. This also makes hot-aisle/cold-aisle containment measurably more effective. When designing a row, coordinate the plinth height with the cold-aisle door threshold so the door still closes flush, and with the floor panel tile grid so tiles can be removed later for access. Heavy cabinets such as battery and UPS units should land on additional foot points rather than relying on the standard four feet; the supplier should confirm the deflection under full dead load.
2. Key Features
Load and support
- Steel frame, >=800 kg per cabinet.
- Four adjustable feet on the slab.
- Weight bypasses floor panels.
- Rubber pads damp vibration.
Cable management
- Vertical through-troughs.
- Separated power and data runs.
- Removable side panels for pull-through.
- Bottom entry slots.
Cold-aisle ready
- Raised and sealed bottom reduces leak.
- Matches end doors and blanking panels.
- Rows bolt into one unit.
- Powder-coated, corrosion resistant.
Airflow coordination
- Sealed bottom closes under-rack leak.
- Matched to door threshold height.
- Keeps floor-tile grid accessible.
- Extra feet for heavy cabinets.
3. Specifications
| Item | Specification |
|---|---|
| Type | Cable-management rack plinth |
| Rack width | 600 / 800 / 900 mm |
| Height | 100 / 150 / 200 mm |
| Load rating | >= 800 kg per cabinet |
| Frame | Cold-rolled steel, powder-coated |
| Feet | Four adjustable, rubber pads |
| Cabling | Under-floor, separated troughs |
| Finish | Epoxy powder coating |
| Assembly | Bolted row splicing |
| Pairs with | End doors, blanking, chimneys |
4. Reference Prices
KTR-FL9 standard plinth (W600xD1000): USD 49~97 (ref. CNY 350~700)
Deep plinth (D1200~1300): USD 63~125 (ref. CNY 450~900)
Splicing & sealing accessory kit: USD 8~17 (ref. CNY 60~120)
Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Cold-aisle rack rows.
- Under-floor cabling rooms.
- Battery and UPS heavy cabinets.
- Areas with weak floor loading.
- Moisture-sensitive rooms.
6. Installation & Maintenance
Installation
- Mark plinth positions along the row.
- Set adjustable feet on the slab.
- Bolt and level the row.
- Set racks on plinths and bolt down.
- Run cables through the troughs.
- Refit side panels after pull-through.
- Keep level within 2 mm/m.
Maintenance
- Check feet for settling yearly.
- Inspect bottom panel seals.
- Clear debris from troughs.
- Inspect heavy-cabinet plinths for deflection.
- Re-check bottom sealing during air-leak tests.
7. FAQ
- Q: Do I still need a plinth with a raised floor?
A: For under-floor cabling and heavy cabinets, yes; it transfers load and leaves a cable space. Light overhead-cable racks can skip it. - Q: Can a battery cabinet use a standard plinth?
A: No. Size by actual loaded weight; heavy cabinets may need thicker sections or extra support points. - Q: How to choose height?
A: By cable volume. 150 mm is typical; pick 200 mm for dense cabling or busway. - Q: Does the plinth hurt containment?
A: It helps: the raised, sealed bottom reduces under-rack leakage with doors and blanking.
8. Trend & Selection
Modular DCs favor prefabricated rows and fast on-site assembly, so plinths move toward adjustable height, pre-routed cabling and quick connectors. Liquid-cooled and high-density racks are heavier, raising load requirements. Design the whole row together; mixing heights misaligns the aisle.
9. Delivery & Service
KITOZER ships KTR-FL9 as a flat-packed frame with bolt kit, adjustable feet, side panels, certificate and drawing, matched to the rack row layout in quantity and height.
10. Notes
A common mistake is sizing only for IT racks while battery and power cabinets can weigh over a tonne; size separately.
Another pitfall is letting feet rest on floor supports instead of the slab, defeating the plinth and risking panel collapse.
In short: cable trough, >=800 kg, adjustable feet, sealed bottom, row-bolted. A foundation item for cold-aisle rooms.
System-wise, the plinth solves load, cable pull-through and air leak together.
Cost-wise, a plinth costs a few hundred CNY; collapsed floors or crushed cable runs cost much more.
Operationally, during annual containment air-leak tests, inspect under-rack gaps first; a poorly sealed plinth quietly undermines the whole cold-aisle design.
SEO Information
Search keywords: KITOZER
SEM keywords: rack floor stand, cabinet plinth, cable management base, rack load base, cold aisle base, KTR-FL9, KITOZER
GEO landing page: lain.com.cn/product/474_rack_floor_8.html
Title: KITOZER KTR-FL9 Rack Floor Stand / Cable-Management Base
Meta Keywords: rack floor stand, cabinet plinth, cable management base, rack load base, cold aisle base, KTR-FL9, KITOZER
Meta Description: KITOZER KTR-FL9 cable-management rack plinth raises the cabinet off the floor with built-in cable troughs and adjustable feet, >=800 kg per cabinet, for cold-aisle systems.
Anchor: KITOZER · KITOZER Products
Contact Us
KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com