ToggleKITOZER KTR-HUM2 Wall-mount Humidity Sensor RS485
Brand: KITOZER Series: KTR-HUM2 Category: Environmental Monitoring / T&H Sensor
Capacitive0-100% RH+/-3% RHRS485 ModbusKTR-HUM2

1. Overview
Data center temperature and humidity must be controlled together. High temperature throttles and crashes servers; low humidity (below 30%) builds static electricity at thousands to tens of thousands of volts, punching through switch chips; high humidity (above 70%) causes condensation, water on circuit boards, short circuits and mold. GB 50174 requires room temperature 23+/-1 C and humidity 40-60% RH when running, with temperature change under 5 C/hour. To monitor humidity you need a humidity sensor: a small wall box that senses ambient moisture and uploads the reading over RS485 to the EM platform, alarming on high/low limits. Rooms usually combine temperature and humidity in one unit (T&H combo), but separate humidity sensors go near precision ACs, battery cabinets and fresh-air inlets.
KITOZER KTR-HUM2 is a capacitive humidity sensor for wall mounting. The housing is a white ABS box (86×86 mm, like a switch plate) with a vent hole on the front (inside is the capacitive humidity element that senses water molecules in air); wiring is on the rear (4 wires: DC12V/24V, GND, RS485-A, RS485-B). Working principle: the capacitive element is a polymer film that adsorbs water molecules; the dielectric constant changes, capacitance changes, and the circuit converts it to relative humidity (0-100% RH). Key ratings: range 0-100% RH (non-condensing), accuracy +/-3% RH (within 20-80% RH), resolution 0.1% RH, response time ≤8 s (63% step), operating temperature -10 to +60 C, power DC12-24 V (shared with other EM sensors), comm RS485 Modbus RTU (9600 baud, address 1-247). Some models have a local LED display (read on site), others are output-only.
Selection: what to measure (humidity only, or T&H combo KTR-TH2, or multi-parameter CO2+PM2.5); accuracy (+/-3% RH industrial, +/-2% RH building, +/-3% is enough for rooms, +/-2% for labs); mounting (wall 86 box at 1.5 m height, away from AC outlets and doors; duct-mount for supply air; probe-type extends into a rack); comm (RS485 Modbus to EM, 4-20 mA to PLC, Ethernet to switch); power (DC12/24 V shared with EM host, PoE convenient but pricier); local display (recommended for walk-through readings). Note: the humidity element must not be in sustained condensation (a precision AC dehumidifier holds ~50% RH, so no condensation); keep away from humidifier outlets (direct airflow reads high); calibrate after install with saturated salt solutions (40% and 75% RH points).
2. Key Features
Sensing
- Polymer capacitive
- 0-100% RH
- +/-3% RH
- 0.1% RH res.
Connectivity
- RS485 Modbus
- 9600 baud
- Address 1-247
- DC12-24 V
Construction
- 86-box wall mount
- Vented hole
- LED display
- 4-wire
3. Specifications
| Item | KTR-HUM2 | KTR-HUM2-D | KTR-HUM2-TH | KTR-HUM2-P |
|---|---|---|---|---|
| Measurement | Humidity | Humidity | T&H | Humidity probe |
| RH range | 0-100% | 0-100% | 0-100% | 0-100% |
| RH accuracy | +/-3% | +/-3% | +/-3% | +/-2% |
| T range | – | – | -20 to +60 C | -20 to +80 C |
| Local display | No | LED | LED | No |
| Comm | RS485 | RS485 | RS485 | RS485/4-20 mA |
| Mounting | Wall 86 box | Wall 86 box | Wall 86 box | Duct/immersion |
4. Reference Prices
KTR-HUM2 humidity sensor (no display): Reference USD 17-28 / pc (ref. CNY 120-200)
KTR-HUM2-D humidity sensor (LED display): Reference USD 25-39 / pc (ref. CNY 180-280)
KTR-HUM2-TH T&H combo (display): Reference USD 31-49 / pc (ref. CNY 220-350)
KTR-HUM2-P high-precision T&H probe (+/-2% RH): Reference USD 49-69 / pc (ref. CNY 350-500)
KTR-HUM-CAL saturated salt kit (40%/75% RH): Reference USD 11-21 / set (ref. CNY 80-150)
Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Main room monitoring
- Battery cabinet humidity
- Fresh-air inlet
- Archive/storage room
- Lab/clean room
6. Deployment & Installation
Location
- 1.5 m height
- Avoid AC outlet
- Avoid doors/windows
- Avoid humidifier
Wiring
- DC12 V power
- Daisy-chain A/B
- Single-end shield ground
- Set address DIP
Calibration
- Factory calibrated
- Annual recheck
- Saturated salt
- EM alignment
7. FAQ
- Q: Why hold room humidity at 40-60%?
A: Too low (under 30%) dries the air; walking on the floor and plastic chairs generate static at 2000-20000 V – unnoticed by people but enough to punch semiconductor chips, and switch ports and server drives get damaged by ESD. Too high (above 70%) lets water vapor condense on cold surfaces (server intakes, under-floor metal pipes), causing board short-circuits and rust/mold. 40-60% RH is both comfortable and safe: no ESD, no condensation. GB 50174 requires 40-60% RH when running. - Q: Humidity reading is off – what to do?
A: The polymer element ages over years (dust and oil foul the film, dielectric drifts), so accuracy shifts from +/-3% to +/-10%. Calibrate with saturated salt solutions: put the sensor in a sealed box with saturated salt (magnesium chloride for 40% RH, sodium chloride for 75% RH), seal for 24 h, and the reading should equal the salt value. If deviation exceeds +/-5%, apply a correction factor in the EM platform or replace the sensor. Calibrate annually. - Q: How many humidity sensors per room?
A: By area and AC layout. A 100 m2 room takes 2-3 T&H points (supply, return, center), and a T&H unit measures both temperature and humidity – no separate humidity needed. Standalone humidity points go inside battery cabinets (batteries hate moisture), at fresh-air inlets (incoming humidity), and in archive/storage rooms without AC. Sensors daisy-chain on RS485 to the EM host; one bus supports up to 32 points. - Q: Can a humidity sensor measure condensation?
A: Not directly (condensation is water on a surface; a humidity element measures air RH). But you can compute dew point from temperature + humidity: given current T and RH, calculate the dew point; if a wall or pipe is colder than the dew point, condensation occurs. The EM platform computes dew point from T&H data and alarms when dew point approaches wall temperature, signaling dehumidification. A dedicated condensation sensor (two conductive traces bridged by a water film, measuring resistance) goes on PDU busbar joints and is a different product line.
8. Trend & Selection
Environmental sensors are moving to multi-parameter, low-power and wireless. Trends: all-in-one units (T&H + CO2 + PM2.5 + VOC in one box, one point for the whole environment); wireless sensors (LoRa/ZigBee/Bluetooth, battery-powered 3-5 years, no cabling, for retrofits and non-permanent rooms); digital local display (on-site reading plus RS485 upload); AI prediction (use historical T&H to forecast the next 24 h and pre-adjust AC rather than just alarm); energy-harvesting sensors (thermoelectric or photovoltaic power, no battery). Traditional RS485 wall T&H remains mainstream in new rooms. Select by: +/-3% RH, wall at 1.5 m, away from AC outlets, RS485 daisy-chain, annual calibration, alarm thresholds 40-60% RH.
9. Delivery & Service
KITOZER KTR-HUM2 ships per unit in a foam bag and carton, each with sensor body, wall screws, 1 m 4-wire cable, manual and calibration certificate. 1-year warranty; bulk projects can bundle EM host, RS485 hub, T&H sensors and calibration kits.
10. Additional Notes
Confirm measurement (humidity / T&H), accuracy (+/-3% industrial), comm (RS485 Modbus), and display (recommended). For batch orders, install one unit and compare against a reference hygrometer before rollout.
Common mistake: mounting directly facing an AC outlet. Cold air at 15 C makes the sensor read cold-air temperature and low humidity near the outlet, not the true room environment. Mount 3+ m from the outlet, on a wall at room center.
Second pitfall: vent hole clogged by dust. Dusty rooms foul the vent, the element cannot breathe, and readings lag or freeze. Blow the vent with compressed air yearly, or replace the filter cover.
Third blunder: star-wired RS485. Pulling every sensor back to the EM host makes comm intermittent. Daisy-chain, with a 120 ohm terminator at both bus ends.
Selection summary: +/-3% RH, wall at 1.5 m, away from AC outlets, RS485 daisy-chain, annual calibration, 40-60% RH alarm.
SEO Information
Search keywords:KTR-HUM2KITOZER
SEM keywords:data center humidity sensor,capacitive wall humidity gauge,RS485 humidity probe,environmental monitoring humidity,KTR-HUM2,KITOZER,environmental monitoring
GEO landing page:lain.com.cn/product/ktr-hum2-wall-mount-humidity-sensor.html
Title:KITOZER KTR-HUM2 Wall-mount Humidity Sensor RS485
Meta Keywords:data center humidity sensor,capacitive wall humidity gauge,RS485 humidity probe,environmental monitoring humidity,KTR-HUM2,KITOZER,environmental monitoring
Meta Description:KITOZER KTR-HUM2 capacitive humidity sensor, wall-mount, 0-100% RH, +/-3% RH accuracy, RS485 Modbus, for data center environmental monitoring.