KITOZER
KITOZER

KITOZER Capacitor Bank: 10kV 600kvar MV Reactive Compensation

The KITOZER 10kV capacitor bank is a medium-voltage power factor correction assembly installed on 10kV distribution busbars to supply reactive power locally, reduce line losses, and raise the available capacity of transformers and feeders. The bank is built from dry-type or oil-immersed shunt capacitors connected in series and parallel groups, with internal fuses, discharge reactors, and switching devices. It is typically controlled by a power factor controller that steps banks in and out to maintain the target power factor. KITOZER supplies the bank in outdoor kiosk and indoor switchgear forms, with harmonic detuning reactors where nonlinear loads are present.

Technical Specifications

Rated voltage 12kV, rated frequency 50Hz, rated reactive power 600kvar, step switching in 100kvar stages, capacitor unit rating per IEC 60871, internal fuse per element, discharge reactor to reduce residual voltage to below 50V within 1 minute. Series detuning reactor at 7% or 14% for harmonic suppression if required. Switching device: vacuum contactor or load break switch. Protection: current-limiting fuses, overvoltage and undervoltage relay, overcurrent protection. Power factor target 0.95 to 0.99. IP rating for outdoor kiosk IP44 or indoor cubicle IP3X. Conforms to IEC 60871 and GB standards.

Applications

The KITOZER 10kV capacitor bank is installed on the 10kV busbar of industrial plants, commercial building substations, and large data center utility switchrooms to correct power factor for inductive loads such as motors, transformers, and HVAC chillers. In textile plants, steel mills, and workshops with many induction motors, the bank reduces demand charges and releases transformer capacity. In mining and water treatment sites, it compensates long cable feeders where reactive voltage drop would otherwise constrain production equipment.

When fitted with detuning reactors, the bank also prevents harmonic resonance that can occur between capacitors and transformer inductance in networks with VFDs, UPS systems, and LED lighting. Outdoor kiosk-type banks are used in solar and wind farms to control power factor at the grid connection point. The bank is switched by a controller that measures power factor in real time and steps stages to avoid overcompensation, which can raise voltage and disturb equipment.

Key Advantages

Local reactive compensation reduces current in upstream cables and transformers, lowering I squared R losses and freeing capacity for additional load. KITOZER uses internally fused capacitors that isolate a failed element without taking the whole unit out of service. The discharge reactor ensures the bank is safe to touch after switching off, which is essential for maintenance. Detuned reactors prevent harmonic amplification and protect capacitors from overcurrent caused by background harmonics.

The stepped switching design matches compensation to actual load, avoiding the overcorrection that can occur with a fixed bank. The controller provides remote monitoring of power factor, stage status, and alarm events via RS485 or Ethernet. Standardized cubicle dimensions allow the bank to be installed in existing switchroom space, and capacitor units are modular so failed units can be replaced individually without scrapping the entire bank.

Installation and Maintenance

Position the bank in a ventilated location with clearance around the cubicle for airflow and cable access. Verify that system voltage matches the capacitor rated voltage, because overvoltage shortens capacitor life. Connect the earthing system to the cubicle earth bar and commission the protection relays before energizing. Set the power factor controller target and step delay so that stages do not cycle rapidly on fluctuating load.

After switching off, wait at least the discharge time before opening the cubicle, and use an earth stick before touching any internal part. Inspect capacitor units annually for bulging, leaks, or noisy operation. Check terminal tightness and measure capacitor capacitance, comparing results to the nameplate. In dusty or corrosive environments, clean insulators and fan filters regularly. Replace any unit showing capacitance drift beyond tolerance, and keep spare units of the same rating on site.

KITOZER builds the 10kV capacitor bank in ratings from 300kvar to several Mvar, with step sizes chosen to match the load profile of the site. It can be supplied with air or gas insulated switchgear, with or without detuning reactors, and with vacuum contactor or circuit breaker switching. When ordering, specify the system voltage, total kvar, step size, the dominant harmonic orders present, and the required control scheme. KITOZER provides a power factor study based on the site load data to recommend the number of steps and the reactor tuning. The bank is factory-tested for protection operation and controller stepping before shipment. Spare capacitor units of the same rating are recommended as critical spares, because a failed unit can be replaced without de-energizing the whole bank. KITOZER also supplies protection relay settings and commissioning support. For outdoor installations, the kiosk can be fitted with space heaters, internal lighting, and a lifting eye for transport. The controller can be integrated into the site SCADA or energy management system for remote monitoring of power factor and stage status.

Price

From $8,800/pc. Contact +86 13922289957 for capacitor bank sizing and detuning options.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com