1. Overview

The KITOZER KTR-FL18 is a mobile 19-inch rack plinth—a rack base or leveling frame—that lifts server, network and cold-aisle enclosures 100-200mm off the floor. The frame is folded and welded from 2.0mm cold-rolled steel with black powder coating. Each corner has an M12 adjustable leveling foot plus four swivel casters (two with brakes): to park, lower the feet to bear load and lift the casters; to move, raise the feet and roll on the casters. Front/rear and bottom cable pass-throughs let power and data cables enter under the rack, suiting under-floor air delivery.

Once racks are placed, business growth often demands moving or adding racks. A plain floor-mounted rack needs several people to lift and pry—slow and risky for the gear. The KTR-FL18 makes the rack movable: braked casters roll it into place, then the brakes lock and the four feet are lowered to level and anchor it—stable yet flexible. Rated for a fully loaded 42U rack, static load is 800-1200kg (by size), caster load 400-600kg (moving condition). It pairs with modular cold-aisle and micro-module racks; a uniform plinth height keeps aisle roofs and containment doors aligned.

Typical deploy: a row of four 42U server racks forming a cold aisle, each sitting on a KTR-FL18 (frame matching rack width 600/800mm, depth 600/1000mm). Roll each rack into the aisle on casters, engage brakes, lower the four feet to level the whole row so seams close tightly; cables enter through the side holes. Select the inner frame by rack width/depth, the load rating by full rack weight, the caster version if you move often, and the plinth height by floor void—lifting the rack also helps under-floor airflow.

2. Key Features

Mobile casters

  • 4 swivel casters.
  • 2 with brake.
  • Easy rolling.
  • Brakes lock.

Leveling feet

  • M12 adjustable feet.
  • Lower to anchor.
  • Four-corner leveling.
  • Compensates uneven floor.

Strong load

  • 2.0mm steel.
  • 800-1200kg static.
  • 400-600kg caster.
  • Black coated.

Cable pass-through

  • Front/rear cutouts.
  • Bottom cable entry.
  • Fits raised floor.
  • Aligns cold-aisle rows.

3. Specifications

项目 KTR-FL18(脚轮可移动) KTR-FL18F(固定脚杯) KTR-FL18H(加高型)
类型 脚轮+脚杯 固定脚杯 脚轮+脚杯
适配机柜宽 600/800mm 600/800mm 600/800mm
适配机柜深 600/800/1000mm 600/1000mm 600/1000mm
抬离高度 100/150mm 100mm 200mm
静态承重 800至1200kg 1000至1500kg 800至1000kg
脚轮承重 400至600kg 无 400kg
脚杯 M12可调 M12可调 M12可调
表面 黑色喷涂 黑色喷涂 黑色喷涂

4. Reference Prices

KTR-FL18 mobile rack plinth (casters+feet, 800mm depth):Reference USD 39 to 90 / unit (ref. CNY 280 to 650 at ~7.2)

KTR-FL18F fixed-foot plinth (non-mobile):Reference USD 25 to 58 / unit (ref. CNY 180 to 420 at ~7.2)

KTR-FL18H raised plinth (200mm lift):Reference USD 49 to 108 / unit (ref. CNY 350 to 780 at ~7.2)

Spare caster / foot:Reference USD 2 to 8 / pc (ref. CNY 15 to 60 at ~7.2)

Reference only; varies by rack width/depth, load rating, caster option and qty. Spare casters/feet, brush seals and row-connect brackets billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Server rack rowing/moving.
  • Modular cold-aisle bases.
  • Micro-module uniform lift.
  • Under-floor cable entry.
  • Flexible/temporary rooms.

6. Installation & Maintenance

Installation

  • Pick frame by rack size.
  • Lower rack onto the plinth.
  • Bolt rack to plinth.
  • Roll on casters to position.
  • Set brakes, lower feet to level.
  • Check row level and seams.

Maintenance

  • Re-level feet after moving.
  • Check caster rolling.
  • Confirm brakes hold.
  • Lube foot threads.
  • Re-tighten bolts.
  • Keep brush seals intact.

7. FAQ

  • Q: Do casters fail under long load?
    A: When parked, the feet bear load and the casters hang free; casters see load only briefly during moves. Long-term weight rests on the steel frame and feet, so casters are not continuously compressed.
  • Q: How high can it lift?
    A: Standard 100/150mm, raised version 200mm. Choose by floor void and under-floor airflow. Too high misaligns aisle roofs and doors—keep the whole row uniform.
  • Q: Is rolling a fully loaded rack safe?
    A: Remove heavy gear or roll in batches. Casters are rated 400-600kg; two people roll slowly, avoid thresholds, and brake immediately once in place.
  • Q: Mobile or fixed base?
    A: Choose casters if you rearrange/expand often; fixed feet if the position is permanent. Keep a cold-aisle row to one height and style.

8. Trend & Selection

Modular and micro-module rooms demand fast deployment and flexible expansion; a mobile rack plinth makes re-rowing like building blocks. Size the load rating by full rack weight; keep aisle rows at a uniform height; casters plus feet balance mobility and stability; fit brush seals on cable cutouts; always re-level after moving. The plinth sits unseen but decides whether the rack is steady, movable and easy to cable.

9. Delivery & Service

KITOZER supplies rack accessories: based on rack dimensions and load list we recommend caster/fixed plinth specs and quantities, plus row connectors and brush entry plates. Delivery includes frame, casters, feet and bolts; bulk projects include on-site positioning and leveling guidance. Deformed frames or failed casters under warranty are replaced free.

10. Additional Notes

The common mistake is letting casters carry long-term load without lowering the feet. Rubber wheels under constant heavy load flatten and deform, tilting the rack. Once parked, lower the feet so the steel frame bears the weight.

Another pitfall is mismatched plinth heights across a cold-aisle row, leaving roofs and doors misaligned and leaking air. Keep the whole row on one model and one lift, and link adjacent bases with row connectors.

Selection summary: 19-inch rack plinth, rollable casters, M12 leveling feet, 800-1200kg static, cable cutouts, uniform row height. The KTR-FL18 lets the rack roll, sit steady and cable cleanly.

SEO Information

Search keywords:rack plinthmobile rack baserack caster baserack leveling feetcold aisle baseKTR-FL18KITOZER

SEM keywords:[rack plinth price,mobile rack base supplier,rack caster base,cold aisle rack base,KTR-FL18,KITOZER]

GEO landing page:lain.com.cn/product/ktr-fl18-mobile-rack-plinth-casters.html

Title:KITOZER KTR-FL18 Mobile Rack Plinth with Swivel Casters

Meta Keywords:rack plinth,mobile rack base,rack caster base,rack leveling feet,cold aisle base,KTR-FL18,KITOZER

Meta Description:KITOZER KTR-FL18 19in mobile rack plinth, 4 braked swivel casters + M12 leveling feet, 800-1200kg static load.

Anchor: KITOZER · Data Center Engineering

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart