The KITOZER Cat6 UTP cable is a 4-pair unshielded twisted-pair copper data cable supplied in a 305m pull box for structured cabling installations. Built with 23AWG solid bare copper conductors and a flame-retardant LSZH or PVC jacket, the cable supports Gigabit Ethernet and short-distance 10GBASE-T links up to 55 meters. The unshielded design is cost-effective and easy to terminate in standard RJ45 keystone jacks and patch panels. It is the default horizontal cable for office, education, and hospitality LAN deployments.
Each pair is twisted at a precise lay length to minimize crosstalk between pairs, and a longitudinal separator inside the jacket reduces alien crosstalk when cables are bundled tightly. The 23AWG solid conductor provides consistent DC resistance for Power over Ethernet applications, supporting PoE+ up to 30W per port over the full 100m channel. The 305m pull box is sized for one typical floor run in multi-story commercial buildings, with an exit port that lets technicians pull cable without tangling the remaining reel.
Technical Specifications
Standard: ANSI/TIA-568.2-D, ISO/IEC 11801. Category: Cat6. Conductor: 23AWG solid bare copper, 4 pairs. Cable diameter: 6.2mm. Jacket: LSZH or PVC, blue or white. Length: 305m (1000ft) pull box. Frequency bandwidth: 250MHz. Maximum bandwidth length: 100m for 1G, 55m for 10G. Flame rating: CMR riser or LSZH. Insulation: HDPE. Operating temperature: -20C to +60C. Packaging: reusable cardboard pull box with exit port. KITOZER, 10 year performance warranty.
The cable is available in CMR riser-rated PVC for vertical shafts and LSZH for plenum and high-occupancy spaces. The blue jacket is the industry standard for data cabling, while white is available for hospitality environments. Every reel is individually tested for NEXT, return loss, insertion loss, and delay skew, and a test report is included with bulk orders.
Applications
This cable is used for horizontal cabling from telecom closets to wall outlets in office buildings, schools, hospitals, and hotels. It supports data, VoIP, and PoE applications including wireless access points, IP cameras, and IP phones. The 305m pull box is sized for one typical floor run in multi-story commercial buildings.
In a typical office floor, the cable runs from a patch panel in the telecom closet through the raised floor or ceiling conduit to a wall outlet near each desk. Each outlet serves a desk phone, a PC, and occasionally a wireless access point. The 250MHz bandwidth supports 1Gbps Ethernet to the desk and short-reach 10G for high-bandwidth workstations. The cable is also used in smart buildings for access control, environmental sensors, and building automation networks.
Key Advantages
Solid 23AWG copper ensures consistent performance across the full 100m channel and supports PoE+ up to 30W per port. The untwist at termination is minimized by maintaining pair geometry near the jacket. The LSZH jacket emits low smoke and zero halogen in a fire, meeting plenum and riser safety codes. The pull box allows technicians to pull cable without tangling and to seal the box between pulls. Every reel is tested for NEXT, return loss, and insertion loss.
The 305m length matches the standard horizontal channel, reducing waste compared with longer reels. The reusable pull box stores the remaining cable safely between jobs. Color-coded pair insulation follows T568B conventions, reducing termination errors. The 10-year performance warranty covers the channel when installed by a certified technician.
Installation and Maintenance
Pull cable with a maximum tension of 110N to avoid stretching conductors. Maintain a minimum bend radius of 25mm during pulling and 4x cable diameter after installation. Do not run parallel to power cables; maintain at least 200mm separation from 220V power lines. At the outlet end, untwist no more than 13mm when terminating the RJ45 keystone. At the patch panel, untwist no more than 13mm and dress pairs neatly.
Test every link with a Cat6-certifying tester and document wire map, length, and insertion loss. Label both ends. During maintenance, recertify links if a patch fails. Do not over-bend the cable around tight corners, as this can increase NEXT. Keep the pull box sealed between pulls to prevent dust contamination.
Packaging and Compliance
Each 305m reel is packed in a reusable cardboard pull box with a side exit port. The box includes a test report, installation guide, and a sample label. RoHS, CMR, and LSZH options available. Custom colors, CMG plenum rating, and bulk pallets are available for large projects.
In a typical office floor, one 305m pull box serves 12 to 16 wall outlets. The technician pulls cable from the box through the raised floor to each outlet, terminating at a Cat6 keystone jack. At the telecom closet, the other end lands on a 24-port Cat6 patch panel. Each link is tested with a certifying tester, and the results are documented in the as-built drawings. Over a 10-year service life, the same cable carries VoIP phones, wireless access points, and PoE security cameras without re-termination.
Price
From $95/box. Contact +86 13922289957 for wholesale Cat6 cable pricing.