ToggleProduct Overview
The KITOZER Cat6A S/FTP cable is a fully shielded 4-pair copper data cable engineered for 10GBASE-T transmission over the full 100m channel. Each pair is individually foil-shielded and the entire cable is wrapped in an overall braid, providing superior alien crosstalk rejection in high-density cable bundles. The 23AWG solid copper conductor and 500MHz bandwidth make this cable suitable for data center top-of-rack cabling, industrial environments, and buildings with high electromagnetic interference.
The S/FTP construction (Screened Foiled Twisted Pair) combines pair-level foil shielding with an overall braid, blocking both electromagnetic interference from external sources and crosstalk between adjacent cables in a bundle. A bare copper drain wire provides reliable shield continuity to grounded patch panels. The violet jacket color identifies Cat6A, distinguishing it from blue Cat6 and yellow OS2 fiber at a glance.
Technical Specifications
Standard: ANSI/TIA-568.2-D, ISO/IEC 11801 Class EA. Category: Cat6A. Conductor: 23AWG solid bare copper, 4 pairs. Shielding: F/UTP or S/FTP (overall braid plus pair foil). Cable diameter: 7.5mm. Jacket: LSZH or PVC, violet. Frequency: 500MHz. Maximum length: 100m at 10GBASE-T. Flame rating: CMR or LSZH. Operating temperature: -20C to +60C. Pulling tension: 110N. Packaging: 305m pull box. KITOZER, 25 year performance warranty.
The S/FTP version adds a tinned copper braid around the foil, providing 90 percent optical coverage for high-interference environments. The drain wire is 0.5mm bare copper and must be bonded to ground at both ends of the channel. The 7.5mm outer diameter is larger than Cat6, so cable trays must be sized accordingly. Every reel is tested for alien crosstalk between adjacent bundles.
Applications
This cable is used in data centers for 10G server-to-switch links, in industrial plants near VFD motors and high-power equipment, and in healthcare facilities sensitive to electromagnetic interference. It is also deployed in smart building networks carrying PoE++ to PTZ cameras and wireless access points, where 10G headroom and shielded continuity are required.
In a data center, the cable runs from the top-of-rack switch to the server in the same rack, typically 3m to 5m long. In industrial plants, it connects PLC controllers to remote I/O modules near variable frequency drives. In hospitals, it carries patient monitor data in operating rooms where MRI and X-ray equipment generate strong electromagnetic fields. The shielded construction ensures signal integrity in these harsh environments.
Key Advantages
The dual-shielded construction reduces alien crosstalk in tight bundles, allowing 24 cables to be packed in the same tray without performance loss. The 500MHz bandwidth supports 10GBASE-T at the full 100m channel length, future-proofing against bandwidth growth. The drain wire provides reliable shield continuity to grounded patch panels. The LSZH jacket meets strict fire safety codes in commercial buildings.
The 25-year performance warranty is the longest in the industry, reflecting confidence in the cable construction. The violet jacket simplifies identification during Moves Adds and Changes. Compared with unshielded Cat6A, the S/FTP version delivers lower alien crosstalk in dense bundles, which is critical in data center cable trays packed with hundreds of cables.
Installation and Maintenance
Pull with a maximum tension of 110N and a minimum bend radius of 8x cable diameter during installation. Maintain the shield continuity by bonding the drain wire to the patch panel or outlet grounding lug at both ends. Use shielded RJ45 keystone jacks and shielded patch panels to preserve the shield. Untwist no more than 13mm at termination.
Test every link with a Cat6A-certifying tester, including alien crosstalk between adjacent links where required. Label both ends and document test results. During maintenance, verify that the drain wire remains bonded to ground at both ends. If shield continuity is broken, the cable becomes vulnerable to EMI. Re-test if a link shows errors.
Packaging and Compliance
Each 305m reel is packed in a reusable pull box with a side exit. The box includes a test report, installation guide, and sample labels. RoHS, CMR, and LSZH compliant. F/UTP and U/UTP variants are available for less demanding environments. Custom colors and bulk pallets are available.
In a data center, a 3m Cat6A S/FTP patch cable runs from the top-of-rack switch to the server, with the drain wire bonded to ground at both ends. The violet jacket distinguishes it from blue Cat6 and yellow fiber. In an industrial plant, the same cable connects a PLC to a remote I/O block near a VFD, and the shield blocks electromagnetic noise that would otherwise corrupt the control signal. Every link is tested with a Cat6A certifier, including alien crosstalk between adjacent cables in the bundle.
Price
From $185/box. Contact +86 13922289957 for Cat6A cable pricing.