KITOZER Cat7 S/FTP cable supports 600MHz bandwidth with individually shielded pairs and overall braid shield, designed for future high speed links, 10GBASE-T long reach, and partial 40GBASE-T short reach in data center environments. The fully screened construction offers superior noise rejection in EMI heavy industrial and broadcast settings, and the LSZH jacket meets public building fire codes. The cable is the highest performance copper cabling in the KITOZER structured cabling family.
Table of Contents
ToggleProduct Overview
The cable uses 23 AWG solid bare copper conductors, individually foil shielded pairs separated by a rigid cross filler, plus an overall tinned copper braid shield. The S/FTP architecture provides pair to pair shielding in addition to overall external shielding, reducing both alien crosstalk and incoming EMI. The LSZH jacket is flame retardant and printed with meter markings, pair code, and flammability rating. A bare copper drain wire ensures continuous shield grounding to the keystone and patch panel.
The rigid cross filler maintains pair spacing even under high bundle compression, which is critical at 600MHz where pair to pair crosstalk is the dominant limitation. The pair foil shield blocks both outgoing crosstalk and incoming EMI per pair, and the overall braid provides a second layer of external shielding. The drain wire is tinned copper for corrosion resistance and runs the full cable length. The LSZH jacket emits minimal smoke and no halogen in fire, satisfying public building code.
Technical Specifications
ISO/IEC 11801 Class F, Cat7 S/FTP, 4 pair, 23 AWG solid bare copper, pair foil plus overall braid, LSZH jacket, bandwidth 600MHz, 10GBASE-T up to 100m, 40GBASE-T up to 30m, insertion loss less than 28dB at 600MHz, NEXT greater than 72dB, shielding attenuation greater than 50dB, operating temperature minus 20 to plus 60 C, 305m pull box, KITOZER, 25 year warranty.
Additional parameters include maximum pull tension 100N, minimum bend radius 8 times after installation, capacitance 52pF at 1kHz, impedance 100 ohm plus or minus 15 ohm, delay skew less than 45ns per 100m, flammability LSZH per IEC 60754, and shielding attenuation 50dB minimum. Compatible with TERA and GG45 connectors. Each reel is tested for insertion loss, NEXT, PSANEXT, and return loss.
Applications
Cat7 S/FTP is deployed in high performance data center top of rack links, broadcast outside broadcast van cables, industrial control rooms near heavy machinery, and military private networks where EMI and crosstalk margins must be large. It is also used in future proof smart building backbones, where the cable supports current 1G and 10G links but leaves headroom for 40G migration. In video production, the cable carries 4K HDMI over HDBaseT extenders with low signal degradation.
Other deployments include electronic warfare facilities, aerospace test ranges, and broadcast transmission plants where EMI rejection is critical. In university research labs, the cable supports instrument networks near RF equipment. The 40GBASE-T short reach capability gives data centers a migration path from 10G to 40G without fiber rewiring in the rack. The LSZH jacket satisfies public building code in hospitals, tunnels, and transit.
Advantages
Pair level shielding eliminates both outgoing and incoming crosstalk, which is the limiting factor at frequencies above 500MHz. 600MHz bandwidth provides significant headroom beyond Cat6A, reducing margin concerns for future upgrades. The rigid cross filler maintains pair spacing even under cable bundle compression. LSZH jacket supports public building compliance. The 25 year warranty covers the channel when paired with KITOZER shielded keystones and GG45 or TERA compatible patch panels.
The 50dB shielding attenuation is 10dB better than Cat6A SFTP, providing extra margin in EMI hostile environments. The 600MHz bandwidth supports 40GBASE-T over 30 meters, which is sufficient for top of rack to server links in dense data halls. The rigid cross filler prevents pair displacement during bundle compression, which preserves crosstalk performance. The pair foil plus overall braid architecture is the gold standard for high frequency shielded copper.
Installation and Maintenance
Use shielded keystones rated for Cat7 and bond the drain wire to the rack ground at both ends. Maximum pull tension is 100N, and minimum bend radius is 8 times the cable diameter after installation. Do not untwist pairs more than 6mm at termination, because pair shield integrity depends on tight twist. Test with a Cat7 certified analyzer and document NEXT and shielding values. Avoid parallel routing near power cables and VFDs, and maintain at least 300mm separation.
Cat7 requires TERA or GG45 connectors rather than standard RJ45, because the RJ45 interface does not support 600MHz. Ensure the patch panel and keystone are Cat7 rated to maintain shield continuity. After installation, verify shield continuity with a multimeter. During quarterly inspection, audit drain wire bonds and tighten rack ground connections. Keep Cat7 rated connectors on site, because unshielded RJ45 breaks the channel performance.
Package Contents and Support
Each pull box contains 305 meters of Cat7 S/FTP cable with printed meter markings, a desiccant bag, and a reel test certificate. KITOZER provides Cat7 channel warranty validation, installation guidance, and 10 year spare cable availability. TERA and GG45 compatible patch panels are available as matching components.
Price
From $260/box 305m. Contact plus 86 13922289957 for Cat7 pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com