ToggleProduct Overview
The KITOZER 100 kW Coolant Distribution Unit is engineered for mid-size HPC clusters, AI training clusters, and high-density colocation rows where 6 to 12 racks demand direct liquid cooling. The CDU couples facility chilled water to a closed secondary loop that feeds rack-level manifolds and cold plates, using a high-efficiency brazed plate heat exchanger as the physical and hydraulic barrier. Two redundant centrifugal pumps with variable-frequency drives maintain constant differential pressure across the secondary loop, automatically adjusting speed as additional racks come online or as thermal load changes. A built-in 20 L expansion tank, automatic make-up valve, and filter assembly make the unit self-contained, while the front-loading touchscreen presents real-time thermal maps, pump curves, and alarm history.
The controller learns the hydraulic signature of the row over the first week of operation and adjusts the pump setpoint to maintain a target manifold pressure at the farthest rack. This adaptive control reduces pumping energy compared with a fixed setpoint, especially on rows with partial rack occupancy. The unit also supports load-sharing between two CDUs on the same row, allowing N+N redundancy by simply paralleling the secondary headers.
Technical Specifications
Cooling capacity 100 kW at 30 C primary inlet and 35 C secondary delta-T. Primary side: DN65 flanged, 30 percent ethylene glycol acceptable. Secondary side: DN50 dual circuit (supply and return), 25 percent propylene glycol. Heat exchanger: 316L stainless steel brazed plate, design pressure 10 bar. Pumps: two redundant 1.5 kW centrifugal pumps, 30 to 50 Hz variable speed, N+1. Filtration: 100 micron duplex filter with isolation valves. Expansion tank 25 L, make-up water connection G1/2. HMI 10 inch color, Modbus TCP, BACnet IP, SNMP v3, four dry-contact alarm relays. Dimensions 1600 x 900 x 2000 mm, weight 520 kg, IP20, CE, KITOZER, 5 year heat exchanger warranty, 2 year pump warranty.
Sensor suite includes dual redundant supply temperature sensors, return temperature, supply and return pressure transducers, ultrasonic flow meter, pump VFD speed feedback, filter differential pressure switch, leak detection tray, and water conductivity meter. The HMI logs 180 days of 1-minute trend data and supports remote dashboard via web browser. Alarm categories cover thermal, hydraulic, pump, filter, leak, and communication. Nominal power draw is 1.6 kW, dropping below 0.6 kW at part load.
Applications
The 100 kW CDU supports 6 to 12 GPU or CPU dense racks with cold plate cold plates drawing 8 to 15 kW per rack. It is a common fit for university supercomputing rooms, pharmaceutical molecular simulation labs, automotive crash simulation facilities, and media rendering studios. The unit also adapts to rear-door heat exchanger retrofits in legacy data halls where raised-floor air conditioning cannot keep pace with increasing rack power density. Because the secondary loop is fully closed, operators can upgrade racks without interrupting facility chilled water service.
Typical installations include AI training clusters with 8 to 16 GPU nodes per rack, genome processing racks with dense CPU and memory, and financial risk simulation rooms with high-frequency compute nodes. The CDU also supports mixed rows where some racks use cold plates and others use rear-door heat exchangers, thanks to the configurable secondary pressure band. Multiple 100 kW CDUs can be paralleled on a single row to scale from 100 kW to 400 kW or more without re-piping.
Key Advantages
The brazed plate heat exchanger delivers up to 96 percent thermal effectiveness, minimizing the temperature gap between primary and secondary loops and allowing higher rack inlet temperatures for free-cooling energy savings. Duplex filtration keeps cold plate micro-channels clean without needing a loop shutdown during filter change. N+1 pump redundancy and redundant sensors on supply temperature and pressure prevent single-point cooling outages. The controller logs 90 days of trend data for capacity planning and energy reporting, and supports remote firmware upgrade over TCP. Compact footprint fits through standard 1200 mm door openings.
Adaptive differential pressure control reduces pumping energy by up to 45 percent at part load compared with fixed-speed systems. The conductivity meter alerts operators to glycol contamination before it causes corrosion. BACnet IP and Modbus TCP support both modern DCIM and legacy BMS. The cabinet is fitted with isolation valves on primary and secondary, allowing pump and heat exchanger service without draining the whole row. Lifting eyes and forklift slots simplify rigging.
Installation and Maintenance
Place the CDU on a reinforced concrete plinth with anti-vibration pads. Connect primary and secondary flanges, route a dedicated 63 A three-phase feed, and verify rotation direction on initial power-up. Flush the secondary loop with deionized water before charging with approved glycol. Monthly inspection: check pump bearing temperature, filter differential pressure, and make-up reservoir level. Annually: test pressure relief valve, inspect heat exchanger gaskets, and recalibrate the supply temperature sensor. The duplex filter can be swapped online by isolating one housing while the other carries flow, eliminating planned downtime.
Commissioning includes verifying pump rotation, bleeding air at high points, setting differential pressure setpoint, and exercising alarm logic. After handover, baseline supply and return temperatures at nominal load and compare during quarterly reviews. Recommended on-site spares: one pump cartridge, one filter element set, one O-ring kit, and one conductivity sensor. Remote support from KITOZER engineers is available over the Modbus TCP port for diagnostics and tuning.
Price
From $19,600 per unit. Contact +86 13922289957 for 100 kW CDU factory quotation and lead time.