KITOZER CDU: 40kW Rack-Mount Coolant Distribution Unit

Product Overview

The KITOZER 40 kW rack-mount CDU brings liquid cooling distribution directly into the server row, eliminating long pipe runs and the pressure loss penalty associated with remote mechanical rooms. Designed as a 19-inch rack insert at 12U height, the unit slots into a standard enclosure next to the compute racks and serves up to two adjacent racks fitted with CPU and GPU cold plates. All major components are front-reachable: the centrifugal pumps, brazed plate heat exchanger, in-line filter, pressure gauges, and control board. The CDU communicates natively with the rack PDU and environment monitoring system, so operators can read coolant temperature, flow rate, and pump status on the same BMS screen that already tracks power and humidity.

Technical Specifications

Rated cooling 40 kW at 10 K secondary delta T. Secondary loop flow 1.7 m3/h, primary loop flow 2.4 m3/h. Primary and secondary connections quick-disjoint flat-face couplings, DN20 on secondary and DN25 on primary. Two redundant magnetic-drive centrifugal pumps, each 0.55 kW, N+1, speed controllable via 0 to 10 V. Brazed plate heat exchanger AISI 316, 30 plates, design pressure 1.6 MPa. In-line 50 micron reusable stainless filter on secondary return. Sensors PT1000 on all four loop nodes, differential pressure switch, conductivity cell, and optional flow meter on each rack drop. Controller ARM-based with 4.3 inch touchscreen, Modbus TCP, SNMPv3, and REST API. Power 230 V single phase, 1.2 kW consumption. Rack height 12U, width 600 mm, depth 900 mm, weight 75 kg. Compatible coolants include 25 to 40% ethylene glycol, propylene glycol, and dielectric fluids with viscosity below 5 cSt at operating temperature.

Application Scenarios

The 40 kW rack CDU fits well in high-density general-purpose compute racks, AI training servers with 2 to 4 GPUs per node, GPU rendering farms, and video editing workstations that previously required spot coolers. It is also a strong choice for retrofit projects where new liquid-cooled servers are added to an existing air-cooled room and the owner does not want to rip out ceiling pipe chases. Because the CDU lives in the row, hot aisle containment remains unchanged and only a pair of primary loop hoses need to be run to the nearest dry cooler or chiller.

Advantages and Features

Mag-drive pumps eliminate the shaft seal leak path common to mechanical seal designs, which matters in a rack where a drip could fall on switchgear. Flat-face quick disconnects allow a rack to be removed for service without spilling coolant, a major safety improvement over threaded ball valves. The onboard controller records seven days of trend data locally and pushes it to the DCIM platform, enabling predictive maintenance on filters and pumps. Modulating pump speed follows actual rack heat load instead of running at fixed rpm, which cuts pump energy by up to 40 percent compared with uncontrolled CDUs.

Installation and Maintenance

Slide the CDU into a 12U rack space, secure with front rack screws, connect primary loop hoses, plug in power and network, and commission using the guided HMI wizard. The wizard walks the operator through filling, venting, leak test, and pump rotation check in about 20 minutes. Maintain by inspecting the filter differential pressure monthly, replacing or cleaning the 50 micron cartridge every six months, and testing the glycol annually. KITOZER stocks spare pump cartridges, sensor probes, and control boards for next-day dispatch from the regional warehouse.