KITOZER CDU: 50kW Coolant Distribution Unit For Edge Liquid Cooling

Product Overview

The KITOZER 50 kW Coolant Distribution Unit (CDU) is a compact, plug-and-play liquid cooling loop engineered for edge computing rooms, small HPC clusters, and high-density GPU rack deployments where traditional air cooling reaches its thermal limits. The CDU sits between the facility chilled water loop (primary side) and the rack-mounted cold plate or rear-door heat exchanger loop (secondary side), isolating the two circuits with a stainless steel plate heat exchanger. Integrated variable-speed pumps maintain a stable 1.0 to 1.5 bar supply pressure to the secondary loop regardless of rack count, while the touchscreen controller monitors supply and return temperature, differential pressure, flow rate, and pump runtime. The unit is delivered fully wired, pressure-tested, and leak-checked at the factory, reducing on-site commissioning to piping connection, electrical connection, and power-on.

The 50 kW CDU is built around a brazed plate heat exchanger selected to deliver 96 percent thermal effectiveness across the design delta-T. The secondary loop is closed and filled with 25 percent propylene glycol, which protects copper cold plates, aluminum manifolds, and stainless piping from corrosion over multi-year service. The controller implements a constant differential pressure control loop that adjusts pump speed based on manifold pressure, not a fixed curve, so energy use tracks actual rack demand. A built-in 20 L expansion tank, automatic make-up solenoid, and 100 micron duplex filter keep loop water clean and pressurized without manual intervention.

Technical Specifications

Cooling capacity 50 kW at 35 C primary inlet and 40 C secondary delta-T. Primary side connection: DN50 flanged, water or glycol solution up to 30 percent. Secondary side connection: DN32 quick-disconnect compatible, 25 percent propylene glycol or dielectric coolant. Plate heat exchanger: 316L stainless steel, brazed, 8 bar design pressure. Pumps: two redundant centrifugal pumps, 750 W each, variable speed 20 to 60 Hz, N+1 configuration. Control: 7 inch color HMI, Modbus TCP, SNMP v3, dry contact alarm outputs. Dimensions 1200 x 800 x 1800 mm, weight 320 kg, IP20 cabinet, CE certified, KITOZER brand, 5 year warranty on heat exchanger and 2 year warranty on pumps.

Additional instrumentation includes supply temperature sensor on secondary, return temperature sensor on secondary, supply and return pressure transducers, flow meter, pump VFD feedback, filter differential pressure switch, and leak detection tray. The HMI logs 90 days of 1-minute trend data and exports CSV over USB. Alarm outputs cover high supply temperature, low differential pressure, pump fault, filter dirty, leak detection, and communication loss. Power consumption at nominal load is 0.8 kW, and at part load the variable-speed pumps draw under 0.3 kW.

Applications

The 50 kW CDU is typically paired with two to four GPU dense racks, each drawing 12 to 25 kW through direct-to-chip cold plates. It also supports small rear-door heat exchanger installations in retrofit data halls where adding a dedicated cooling plant is impractical. Typical users include edge colocation sites, university HPC labs, architectural render farms, seismic and medical imaging clusters, and industrial simulation rooms. Because the secondary loop is closed and isolated from facility water, the CDU also protects IT equipment from contamination, water hammer, and pressure transients originating in the building chilled water system.

Common edge deployments include 5G core sites, broadcast media editing booths, and factory-floor simulation nodes where a single rack or two racks exceed air cooling capacity. The CDU is also a natural choice for research labs and pilot AI inference rooms that do not yet justify a row-level plant but need production-grade reliability. The compact footprint fits through standard doorways and into a 600 mm wide equipment corridor, making it suitable for retrofit in legacy buildings.

Key Advantages

N+1 pump redundancy ensures that a single pump fault does not interrupt cooling to live GPU racks. The variable-speed pump curve lowers idle energy consumption by up to 40 percent compared with fixed-speed CDUs. Stainless steel primary and copper-brazed secondary wetted parts resist corrosion even with long-life glycol solutions. The integrated leak detection sensor tray alarms before any drip reaches the floor, and the electrically isolated heat exchanger prevents galvanic coupling between dissimilar metal piping. Modbus TCP and SNMP integration feed temperature, pressure, and pump status directly into DCIM or BMS platforms for remote monitoring.

The brazed plate heat exchanger requires no gasket replacement over the design life, reducing maintenance compared with gasketed designs. Duplex filtration allows online filter change without loop shutdown. The HMI supports multi-language operation and remote firmware upgrade. The cabinet is fitted with lifting eyes and forklift slots for safe handling. All wetted parts are pressure-tested to 1.5 times working pressure at the factory, and a serial number plate supports audit and spare parts ordering.

Installation and Maintenance

Install the CDU on a level concrete or anti-vibration pad, connect primary and secondary piping with the provided flanges or quick disconnects, and route a dedicated 32 A three-phase supply. Flush the secondary loop before connecting racks to remove installation debris. Schedule quarterly checks: inspect pump vibration, verify filter differential pressure, test the alarm relays, and record HMI trends. Annually inspect the plate heat exchanger gaskets and refresh the glycol concentration with a refractometer. The pump cartridges can be swapped in under 30 minutes without draining the loop, and the control board is front-accessible.

Commissioning steps include: verify pump rotation, bleed air from the secondary loop at high points, set the differential pressure setpoint to match rack design, and confirm alarm logic by simulating a high-temperature condition. After commissioning, operators should baseline supply and return temperatures at nominal load and compare against the baseline during quarterly inspections. Spare parts recommended on-site include one pump cartridge, one set of filter elements, and one O-ring kit for quick disconnects. Contact KITOZER support for remote diagnostics and firmware updates.

Price

From $11,800 per unit. Contact +86 13922289957 for factory CDU quotation, lead time, and customization options.