The KITOZER 50kW Coolant Distribution Unit (CDU) is a compact, plug-and-play liquid cooling loop engineered for edge computing rooms, small HPC clusters, and high-density GPU rack deployments where traditional air cooling reaches its thermal limits. The CDU sits between the facility chilled water loop (primary side) and the rack-mounted cold plate or rear-door heat exchanger loop (secondary side), isolating the two circuits with a stainless steel plate heat exchanger. Integrated variable-speed pumps maintain a stable 1.0 to 1.5 bar supply pressure to the secondary loop regardless of rack count, while the touchscreen controller monitors supply and return temperature, differential pressure, flow rate, and pump runtime. The unit is delivered fully wired, pressure-tested, and leak-checked at the factory, reducing on-site commissioning to piping connection, electrical connection, and power-on.
Technical Specifications
Cooling capacity 50 kW at 35 C primary inlet and 40 C secondary delta-T. Primary side connection: DN50 flanged, water or glycol solution up to 30 percent. Secondary side connection: DN32 quick-disconnect compatible, 25 percent propylene glycol or dielectric coolant. Plate heat exchanger: 316L stainless steel, brazed, 8 bar design pressure. Pumps: two redundant centrifugal pumps, 750 W each, variable speed 20 to 60 Hz, N+1 configuration. Control: 7 inch color HMI, Modbus TCP, SNMP v3, dry contact alarm outputs. Dimensions 1200 x 800 x 1800 mm, weight 320 kg, IP20 cabinet, CE certified, KITOZER brand, 5 year warranty on heat exchanger and 2 year warranty on pumps.
Applications
The 50 kW CDU is typically paired with two to four GPU dense racks, each drawing 12 to 25 kW through direct-to-chip cold plates. It also supports small rear-door heat exchanger installations in retrofit data halls where adding a dedicated cooling plant is impractical. Typical users include edge colocation sites, university HPC labs, architectural render farms, seismic and medical imaging clusters, and industrial simulation rooms. Because the secondary loop is closed and isolated from facility water, the CDU also protects IT equipment from contamination, water hammer, and pressure transients originating in the building chilled water system.
Key Advantages
N+1 pump redundancy ensures that a single pump fault does not interrupt cooling to live GPU racks. The variable-speed pump curve lowers idle energy consumption by up to 40 percent compared with fixed-speed CDUs. Stainless steel primary and copper-brazed secondary wetted parts resist corrosion even with long-life glycol solutions. The integrated leak detection sensor tray alarms before any drip reaches the floor, and the electrically isolated heat exchanger prevents galvanic coupling between dissimilar metal piping. Modbus TCP and SNMP integration feed temperature, pressure, and pump status directly into DCIM or BMS platforms for remote monitoring.
Installation and Maintenance
Install the CDU on a level concrete or anti-vibration pad, connect primary and secondary piping with the provided flanges or quick disconnects, and route a dedicated 32 A three-phase supply. Flush the secondary loop before connecting racks to remove installation debris. Schedule quarterly checks: inspect pump vibration, verify filter differential pressure, test the alarm relays, and record HMI trends. Annually inspect the plate heat exchanger gaskets and refresh the glycol concentration with a refractometer. The pump cartridges can be swapped in under 30 minutes without draining the loop, and the control board is front-accessible.