KITOZER CDU: 80kW In-Rack CDU For AI Servers

Product Overview

The KITOZER 80 kW in-rack CDU is purpose built for AI training and inference racks where a single rack may dissipate 60 to 100 kW across GPUs, CPUs, memory, and switch assemblies. Instead of treating the rack as one big air box, the CDU distributes conditioned coolant through an internal manifold to every cold plate and to the rear-door heat exchanger that picks up the remaining air-side heat. The unit occupies 18U inside the same 42U rack, leaving the rest of the rack for compute and networking. Factory assembly includes pump redundancy, heat exchanger, filtration, water make-up, leak detection, and a controller tuned for GPU transient loads that swing by tens of kilowatts within seconds. The result is a rack that behaves like a self-contained thermal zone, requiring only primary loop water and power from the facility.

Technical Specifications

Cooling capacity 80 kW at secondary supply 35 C and return 45 C. Secondary loop flow 3.5 m3/h, primary loop flow 4.5 m3/h. Connections primary DN40, secondary split into four DN20 drops for cold plates plus one DN25 drop for rear-door. Pump set two 0.9 kW wet-rotor pumps, N+1, electronically commutated, speed range 2000 to 5500 rpm. Plate heat exchanger 60 plates AISI 316 copper brazed. Filter 100 micron duplex with changeover valve, so filter service occurs without shutting the loop. Expansion tank 15 L, make-up from building water via solenoid with backflow preventer. Sensors PT100 on all four loop nodes, pressure transducers, ultrasonic flow meter on each drop, conductivity, and four leak-sensing cables routed under the manifold. Controller 7 inch HMI, Modbus TCP, BACnet/IP, SNMP, REST, and MQTT for cloud DCIM. Power 230 V single phase, 2.0 kW consumption. Dimensions 600 x 1100 x 800 mm, weight 165 kg. Rated ambient 5 to 40 C.

Application Scenarios

Primary applications include AI training racks with 8 to 16 GPUs, high-frequency trading compute clusters, liquid-cooled HPC nodes in research centers, and edge inference installations serving generative AI workloads. The CDU also supports retrofits of legacy racks that have been upgraded from air-cooled CPUs to liquid-cooled accelerators, because it integrates with existing primary water loops through a standard brazed plate interface. Additional use cases include VFX render farms, seismic processing clusters, automotive design simulation racks, and medical imaging compute for tomography reconstruction.

Advantages and Features

The duplex filter with changeover valve means filter service is a live process, not a planned outage, which is critical for GPU clusters that run training jobs lasting weeks. Per-drop flow metering lets the operator detect a blocked cold plate on a specific server before the server thermal-throttles. High-speed pump response handles GPU load spikes within one second, preventing momentary over-temperature alarms. The controller exposes a REST API that orchestration software can poll to correlate coolant temperature with GPU utilization, useful for capacity planning. All wetted parts are stainless 316 or brass with EPDM seals, compatible with long-life inhibited glycol mixtures.

Installation and Maintenance

Install the CDU in the lower 18U of the rack, anchor to the rack rails, and connect primary loop hoses to the building drop. Commissioning includes a 30 minute pressure hold at 1.2 times working pressure, loop flush to 50 micron cleanliness, and a 24 hour burn-in run monitored by the controller. Preventive maintenance: clean or replace filter cartridge every 6 months, sample glycol annually for pH and inhibitor, inspect pump currents every quarter, and test leak cable continuity once a year. KITOZER offers a 24 month extended warranty covering pump wet ends and the control board. Recommended on-site spares include one filter cartridge, one pump rotor, and one PT100 sensor set.

Price

From $12,800/unit. Contact +86 13922289957 for AI rack CDU quotation.