KITOZER
KITOZER

KITOZER CDU Monitor: Web HMI Controller With Modbus TCP

Product Overview

The KITOZER CDU monitor is a wall-mount or rack-mount controller that unifies temperature, pressure, flow, and pump status across a row of CDUs into a single web-based dashboard. The monitor connects to each CDU over Modbus TCP, aggregates supply and return temperature, differential pressure, pump VFD speed, filter status, and alarm history, and presents trends in a browser-based HMI. Alarms are pushed via SNMP, email, or dry contacts to the DCIM and on-call engineer. The monitor supports up to 32 CDUs and 256 sensors, making it suitable for an entire liquid-cooled hall.

Technical Specifications

Processor: ARM quad-core, 2 GB RAM, 32 GB eMMC. Ports: 2 x Ethernet, 4 x RS485 Modbus, 8 x dry contact inputs, 4 x relay outputs. Protocols: Modbus TCP, Modbus RTU, BACnet IP, SNMP v3, MQTT, REST API. Dashboard: web-based, responsive, multi-language. Alarm: email, SNMP trap, on-screen pop-up, relay. Data logging: 1 year of 1-minute trend data. Power 100 to 240 VAC, 30 W. Dimensions 1U rack mount, 482 x 200 x 44 mm, weight 3 kg. KITOZER, CE, 3 year warranty.

Applications

The monitor is deployed in any hall with two or more CDUs, where operators need a unified view of cooling performance. Typical deployments include HPC data halls, AI training clusters, immersion cooling bays, and industrial liquid cooling skids. The monitor also supports remote hands-off operation for unmanned edge sites, where the on-call engineer receives alarms on a mobile device and can diagnose the issue from a browser.

Key Advantages

Unified dashboard across up to 32 CDUs eliminates per-unit HMI checks. 1-year trend log supports capacity planning and energy reporting. Multi-protocol support integrates with legacy BMS and modern DCIM. REST API and MQTT feed data into custom analytics platforms. Redundant Ethernet ports support network failover. 1U rack mount fits in any network rack. Web-based HMI removes the need for proprietary client software.

Installation and Maintenance

Mount the monitor in the network rack, connect to the CDU subnet, and assign a static IP. Add each CDU by IP address, and the monitor auto-discovers Modbus registers. Configure alarm thresholds and notification recipients. Monthly: review alarm history and trend reports. Quarterly: verify SNMP and email notifications. Annually: back up configuration and update firmware. The monitor requires no sensors of its own and uses CDU data exclusively.

Price

From $1,950 per unit. Contact +86 13922289957 for CDU monitor pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top