Table of Contents
ToggleProduct Overview
The KITOZER CDU monitor is a wall-mount or rack-mount controller that unifies temperature, pressure, flow, and pump status across a row of CDUs into a single web-based dashboard. The monitor connects to each CDU over Modbus TCP, aggregates supply and return temperature, differential pressure, pump VFD speed, filter status, and alarm history, and presents trends in a browser-based HMI. Alarms are pushed via SNMP, email, or dry contacts to the DCIM and on-call engineer. The monitor supports up to 32 CDUs and 256 sensors, making it suitable for an entire liquid-cooled hall.
The monitor runs an embedded Linux controller with a 7 inch local HMI and a responsive web dashboard accessible from any browser. It auto-discovers CDUs on the Modbus TCP subnet and polls each unit every 5 seconds. Trend data is stored for 1 year at 1-minute resolution, and CSV exports are available over USB or web download. The monitor also supports REST API and MQTT for integration with custom analytics platforms and data lakes.
Technical Specifications
Processor: ARM quad-core, 2 GB RAM, 32 GB eMMC. Ports: 2 x Ethernet, 4 x RS485 Modbus, 8 x dry contact inputs, 4 x relay outputs. Protocols: Modbus TCP, Modbus RTU, BACnet IP, SNMP v3, MQTT, REST API. Dashboard: web-based, responsive, multi-language. Alarm: email, SNMP trap, on-screen pop-up, relay. Data logging: 1 year of 1-minute trend data. Power 100 to 240 VAC, 30 W. Dimensions 1U rack mount, 482 x 200 x 44 mm, weight 3 kg. KITOZER, CE, 3 year warranty.
The monitor supports up to 32 CDUs over Modbus TCP and 256 sensors total. Dual Ethernet ports support redundant network paths. RS485 ports connect legacy CDUs with RTU. Dry contact inputs accept external alarm contacts from leak detection and power distribution. Relay outputs can trigger CDU shutdown or alarm horns. The web dashboard supports multi-language English, Chinese, and other on request.
Applications
The monitor is deployed in any hall with two or more CDUs, where operators need a unified view of cooling performance. Typical deployments include HPC data halls, GPU training clusters, immersion cooling bays, and industrial liquid cooling skids. The monitor also supports remote hands-off operation for unmanned edge sites, where the on-call engineer receives alarms on a mobile device and can diagnose the issue from a browser.
Common installations include HPC data halls with 4 to 16 CDUs, GPU training clusters, immersion cooling bays, and industrial liquid cooling skids. The monitor also supports unmanned edge sites where on-call engineers receive alarms by email or SNMP trap and diagnose issues from a browser. REST API feeds trend data into custom analytics platforms for capacity planning and energy reporting.
Key Advantages
Unified dashboard across up to 32 CDUs eliminates per-unit HMI checks. 1-year trend log supports capacity planning and energy reporting. Multi-protocol support integrates with legacy BMS and modern DCIM. REST API and MQTT feed data into custom analytics platforms. Redundant Ethernet ports support network failover. 1U rack mount fits in any network rack. Web-based HMI removes the need for proprietary client software.
Unified dashboard across 32 CDUs. 1-year trend log. Multi-protocol support. REST API and MQTT. Redundant Ethernet. 1U rack mount. Web-based HMI. Auto-discovery of CDUs. CSV export. Multi-language.
Installation and Maintenance
Mount the monitor in the network rack, connect to the CDU subnet, and assign a static IP. Add each CDU by IP address, and the monitor auto-discovers Modbus registers. Configure alarm thresholds and notification recipients. Monthly: review alarm history and trend reports. Quarterly: verify SNMP and email notifications. Annually: back up configuration and update firmware. The monitor requires no sensors of its own and uses CDU data exclusively.
Commissioning includes static IP assignment, CDU discovery, alarm threshold configuration, and notification setup. After handover, baseline trend data at nominal load. Recommended on-site spares: none, as the monitor has no field-serviceable parts. Firmware updates are available over web download.
Typical Configuration
A 10-rack row with two 100 kW CDUs uses one monitor unit. The monitor polls both CDUs every 5 seconds, logs trend data, and sends alarms to the DCIM and on-call engineer. For a hall with 10 rows, one monitor covers 20 CDUs. The monitor also integrates with the leak detection system, pulling zone status over dry contacts and displaying leak alarms alongside CDU alarms.
Design Notes
The monitor is designed for 24/7 operation in a data hall environment, with fanless cooling and redundant network input. The embedded Linux controller boots in under 30 seconds and resumes polling automatically after power restoration. Alarm thresholds are fully configurable: high supply temperature, low differential pressure, pump fault, filter dirty, leak detection, and communication loss each have separate setpoints and notification recipients. The monitor also supports scheduled reports, emailing a daily trend summary to the facilities team. Multi-user access with role-based permissions supports both operators and maintenance engineers.
Price
From $1,950 per unit. Contact +86 13922289957 for CDU monitor pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com