The KITOZER 800RT oil free centrifugal chiller is designed for large central cooling plants in high rise office buildings, convention centers, data centers, and industrial district cooling stations. Using magnetic bearing centrifugal compressors with variable frequency drive, the chiller achieves industry leading part load efficiency above 0.25 kW per ton under IPLV conditions. The oil free design eliminates oil film heat transfer resistance in heat exchangers and removes oil management components, delivering consistent heat exchanger performance over the full product life and reducing annual maintenance cost substantially.
Magnetic bearing technology levitates the compressor shaft without physical contact, eliminating friction losses, lubrication systems, and wear surfaces. The shaft spins at speeds up to 45,000 rpm driven by a high speed permanent magnet motor. Active magnetic bearings continuously adjust rotor position thousands of times per second, maintaining sub micron clearance. An integrated UPS bridges short power interruptions, gently lowering the rotor to landing bearings during unexpected shutdown.
Table of Contents
ToggleProduct Overview
Each KITOZER magnetic bearing chiller integrates a high speed direct driven centrifugal compressor, flooded type evaporator with enhanced tube bundle, and water cooled condenser with subcooling circuit. The magnetic levitation bearing requires no lubrication oil, no oil pump, and no oil heater. The integrated VFD cabinet soft starts the motor, reducing inrush current to less than 1.5 times rated current. The controller provides full color touch screen, trend logging, alarm history, and dual communication ports for BMS integration. Optional inverter driven condenser water pump control and free cooling integration further improve seasonal efficiency.
The chiller controller supports factory remote diagnostics via Ethernet, allowing engineers to review operating data and suggest maintenance before faults occur. Firmware updates can be uploaded remotely, eliminating service trips for software improvements. The controller also implements demand response logic, automatically reducing cooling capacity by 20 to 30 percent during grid signal events to earn utility incentives.
Technical Specifications
Cooling capacity 800 RT (2813 kW), COP up to 6.3 kW per kW at full load, IPLV up to 11.5 kW per kW. Magnetic bearing centrifugal compressor, VFD driven, speed range 100 to 450 Hz. Evaporator water flow 480 m3 per h, 7 C to 12 C delta T. Condenser water flow 580 m3 per h, 30 C to 37 C. Power supply 3 phase 380 V 50 Hz or 10 kV high voltage option. Rated input power 446 kW, full load current 780 A at 380 V. Refrigerant R134a or R1234ze low GWP. Sound level 85 dB(A) at 1 m. Net weight 12500 kg. CE, AHRI certified, 5 year compressor warranty.
Application Scenarios
This chiller is ideal for mission critical facilities where energy efficiency and reliability are the top priorities. Typical installations include Tier 3 and Tier 4 data center central plants, large shopping mall district cooling, hospital and university central chilled water plants, and industrial process cooling for pharmaceutical and electronics manufacturing. The oil free design is particularly suitable for facilities with limited maintenance staffing, as it eliminates periodic oil analysis, oil change, and oil heater monitoring. Multiple units can be sequenced on the BMS to optimize plant load distribution across the day.
In hot climates, the chiller pairs with open cooling towers operating at design wet bulb. In moderate climates, partial free cooling through a plate heat exchanger allows the chiller to unload during winter. The 10 kV direct drive option eliminates the need for a step down transformer, saving electrical room space and transformer losses. For district cooling projects, multiple 800RT units can be staged from 10 percent to 100 percent, covering loads from 100 RT to 4800 RT smoothly.
Advantages and Features
Magnetic bearing technology cuts friction losses by more than 90 percent compared with traditional oil lubricated centrifugal chillers. The chiller can operate down to 10 percent of rated capacity without hot gas bypass, matching low load night time conditions smoothly. The VFD provides stable operation even when condenser water temperature varies seasonally. Partial heat recovery option captures condenser heat for domestic hot water or reheat coils. The integrated starter eliminates the need for a separate VFD panel, saving electrical room space. Remote monitoring via Ethernet allows factory diagnostics and firmware updates.
Because there is no oil circuit, the heat exchangers stay clean internally for the life of the machine. Traditional centrifugal chillers lose 5 to 10 percent efficiency within five years due to oil fouling on tubes; the magnetic bearing chiller maintains original efficiency indefinitely. Sound levels are 10 to 15 dB(A) lower than equivalent oiled machines because there are no gearbox and no oil pump noise.
Installation and Maintenance
Position the chiller on a level reinforced concrete foundation with spring vibration isolators. Ensure adequate clearance for tube bundle extraction at the rear side. Connect water piping with flexible couplings and install Y strainers on both inlet and outlet. Provide a dedicated power supply with isolation transformer if the site voltage is unstable. Commissioning includes recording compressor magnetic bearing run out, verifying sensor calibration, and tuning BMS points.
Quarterly maintenance checks include condenser and evaporator pressure, current unbalance, and water flow switch function. Since there is no oil system, annual service focuses on electrical terminal torque, contactor condition, and condenser tube cleanliness. Every two years, inspect the VFD capacitors and cooling fans. Every five years, recalibrate magnetic bearing position sensors. The chiller controller automatically tracks runtime and prompts service intervals based on actual operating hours rather than calendar time.
Price
From $68,000 per unit. Contact KITOZER for project pricing, factory test report, and delivery schedule.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com