ToggleKITOZER KTR-CV Precision AC Check Valve
Brand: KITOZER Series: KTR-CV Category: Data Center Engineering / AC Piping
Brass bodyDN15-DN25R410A readyAnti-backflowKTR-CV

1. Overview
A room precision air conditioner runs a closed refrigerant loop: the compressor squeezes low-pressure cold refrigerant into high-pressure hot gas, sends it to the outdoor condenser where it sheds heat and becomes liquid, then the expansion valve throttles it back to low pressure so it can absorb heat in the indoor evaporator. The loop must be one-way. If refrigerant flows backward, the compressor suffers liquid slugging, hard starts, and efficiency loss; in severe cases it burns out. A check valve (non-return valve) is a small fitting on the refrigerant line that lets refrigerant pass one way and automatically closes on reverse flow. It is small but essential in VRF systems, parallel compressor racks, and long-pipe runs.
KITOZER KTR-CV is a brass check valve purpose-built for room precision AC refrigerant lines. KTR-CV-15: DN15 (2-flare) solder or thread connection, 4.5 MPa rated, for units under 10 kW. KTR-CV-22: DN22 (4-flare), for 20 to 50 kW units. KTR-CV-25: DN25 (6-flare), for units above 50 kW. The body is forged HPb59-1 brass, seals are NBR refrigerant-rated rubber, and the poppet uses a 304 stainless spring with a PTFE sealing head. Cracking pressure ranges 0.05 to 0.35 MPa. Compatible refrigerants include R22, R410A, R134a and R407C.
Selection: confirm pipe size (match the copper tube diameter to DN15/22/25); confirm connection (solder for permanent joints, thread for serviceable); confirm direction (an arrow on the body marks flow direction — install backwards and it blocks the line); confirm cracking pressure (long pipe runs prefer low cracking pressure to minimize pressure drop). Mount horizontally with the poppet upright — never vertical or upside-down.
2. Key Features
Body Materials
- Forged HPb59-1 brass body
- 304 stainless spring
- PTFE poppet seal head
- NBR refrigerant-rated O-rings
Performance
- 4.5 MPa working pressure
- 0.05 to 0.35 MPa cracking pressure
- -40 to +120 C operating temp
- R22/R410A/R134a compatible
Connections
- Solder (hard copper joint)
- Thread (serviceable)
- Flange (large bore option)
- DN15 / DN22 / DN25
3. Specifications
| Item | KTR-CV-15 | KTR-CV-22 | KTR-CV-25 |
|---|---|---|---|
| Bore | DN15 (2-flare) | DN22 (4-flare) | DN25 (6-flare) |
| Connection | Solder/Thread | Solder/Thread | Solder/Flange |
| Working pressure | 4.5 MPa | 4.5 MPa | 4.5 MPa |
| Cracking pressure | 0.05 MPa | 0.10 MPa | 0.15 MPa |
| Cooling capacity | Under 10 kW | 20-50 kW | Above 50 kW |
| Body | Brass | Brass | Brass |
| Typical use | Small precision AC | Medium precision AC | Large precision AC |
4. Reference Prices
KTR-CV-15 DN15 check valve: Reference USD 3.5 to 6.3 / pc (ref. CNY 25 to 45 at ~7.2)
KTR-CV-22 DN22 check valve: Reference USD 4.9 to 8.3 / pc (ref. CNY 35 to 60 at ~7.2)
KTR-CV-25 DN25 check valve: Reference USD 6.9 to 11.8 / pc (ref. CNY 50 to 85 at ~7.2)
Refrigerant-rated gasket pack: Reference USD 0.7 to 1.4 / pack (ref. CNY 5 to 10 at ~7.2)
Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Precision AC refrigerant-line anti-backflow.
- VRF / multi-split outdoor unit side.
- Parallel compressor common condenser loops.
- Long-pipe systems preventing shutdown backflow.
- Cold storage / constant-temp-humidity labs.
6. Deployment & Installation
Placement
- Install between compressor discharge and condenser
- Horizontal mount, arrow in flow direction
- At least 30 cm from compressor outlet
- Avoid high-vibration spots
Brazing
- Wrap body with wet rag during brazing
- Protect internal seals from heat
- Nitrogen pressure-test 24 h after brazing
- Evacuate before charging refrigerant
Maintenance
- Check for frost on body (internal leak)
- Listen for abnormal flow noise (poor seal)
- Compare body-end temperatures (should match)
- Replace as a unit; do not disassemble
7. FAQ
- Q: What happens if the check valve is installed backwards?
A: It blocks the line completely — no refrigerant passes, the AC stops cooling, and the compressor trips on high-pressure. A cast arrow on the body marks flow direction. If the AC won’t cool and the high-side gauge pegs, check the valve orientation first. Remove and re-brazed correctly; the body itself is not damaged. - Q: How do I detect an internal leak?
A: An internal leak means the poppet doesn’t seal and refrigerant seeps backward. Test: after shutdown, feel the copper tubes on both sides. Normally the high side slowly drops while the low side stays low. If the low side rises to equal the high side quickly after shutdown, the valve is leaking. Internal leak causes liquid slugging on next start. Replace promptly. - Q: Does every precision AC need a check valve?
A: Not always. Single units with short pipe runs (under 5 m between indoor and outdoor) rarely need one. But install one when: (1) VRF/parallel racks (multiple compressors share lines — prevents backfeed from running compressors to stopped ones); (2) long pipe runs over 15 m (gravity drives refrigerant back after shutdown); (3) outdoor temps below 0 C (condensed refrigerant flows back). - Q: Check valve vs shut-off valve?
A: A shut-off valve is manually operated, installed at service ports, normally fully open and closed only for isolation. A check valve is automatic — refrigerant pressure pushes it open and reverse flow closes it. They serve different purposes: shut-off for service isolation, check valve for anti-backflow. A system needs both.
8. Trend & Selection
Room precision ACs are trending toward larger capacity, VRF, and longer pipe runs, so check valve usage grows in step. Integrated electronic-expansion-valve + check-valve modules are emerging, combining throttling and anti-backflow in one block to reduce brazed joints and leak points. Eco refrigerants (R32) demand higher body pressure ratings — R32 runs about 10% higher than R410A, so choose 5.0 MPa bodies. Smart direction: pressure-sensor check valves that monitor differential pressure and report internal leaks remotely. Select by forged brass body, 4.5 MPa+ rating, NBR seals, prefer brazed joints, horizontal mount with arrow in flow direction. A check valve is small but a wrong install or internal leak can destroy a compressor worth thousands of dollars — do not skip this part.
9. Delivery & Service
KITOZER supplies KTR-CV by bore (DN15/22/25) and connection (solder/thread/flange). Each ships with valve body, gaskets and manual. 1-year warranty; batch projects can bundle shut-off valves, expansion valves, copper tubing and insulation.
10. Additional Notes
Top mistake: brazing without wrapping the body. The NBR seals and PTFE poppet cannot withstand torch heat; direct flame warps them and causes internal leaks within months. Always wrap the body in a wet rag, or remove the poppet before brazing and reinstall afterward.
Second pitfall: buying by price only. Cheap valves use zinc-alloy bodies — light, thin-walled, and corroded through by refrigerant within two years. Room ACs need forged HPb59-1 brass: solid in hand, smooth surface, no sand holes.
Third blunder: mounting on a vertical pipe. The poppet relies on spring + gravity to close; vertical mounting skews the poppet weight and hurts sealing. Mount horizontally with the poppet upright so spring and gravity work together.
Selection summary: brass body, 4.5 MPa+, NBR seals, horizontal mount arrow in flow direction, wrap body when brazing. The check valve is the small guardian of the AC loop — install it right to protect the compressor.
SEO Information
Search keywords:KTR-CVKITOZER
SEM keywords:check valve,non-return valve,precision AC check valve,room AC check valve,refrigerant check valve,KTR-CV,KITOZER
GEO landing page:lain.com.cn/product/check_valve.html
Title:KITOZER KTR-CV Precision AC Check Valve
Meta Keywords:check valve,non-return valve,precision AC check valve,room AC check valve,refrigerant check valve,KTR-CV,KITOZER
Meta Description:KITOZER KTR-CV precision AC check valve: brass body, DN15 to DN25, for R22/R410A, prevents refrigerant backflow.
Anchor: KITOZER by Guangzhou Laian · KITOZER products
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com