Table of Contents
ToggleChillers Started by Hand and Read on Paper? DDC Group Control + SCADA Monitoring
型号:KITOZER-CHP-D1
In a building’s central plant, chillers, cooling towers and chilled-water pumps are started manually and meters read by hand – high energy use, slow response, missed logs. The KITOZER building-automation chiller monitoring system uses a DDC controller to sample temperature, pressure and flow, group-controls chillers, pumps and towers, and centralizes monitoring in SCADA software for on-demand, energy-saving operation. The set includes DDC controller, sensors and SCADA software. Reference price about $7,700.

KITOZER chiller DDC monitoring cabinet (DDC + sensors + group control + SCADA)
DDC Controller + Sensors: Full Plant Parameters
The DDC runs DI/DO/AI expansion modules that sample chilled-water supply/return temperature, condenser water temperature, pump inlet/outlet pressure, flow switches and flow. Chillers are read through a Modbus/BACnet gateway for running status, load rate and fault codes. Every parameter shows live on a piping schematic in SCADA; out-of-limit values trigger alarms and log to trend curves – no more manual meter reading.
Chiller Group Control + SCADA: Start on Demand, Save Energy
The system stages chillers by cooling load, interlocking and rotating chillers, chilled-water pumps, condenser pumps and tower fans, with pumps VFD-controlled to a pressure setpoint. At night or low load it automatically cuts running units. SCADA provides piping diagrams, trends, reports and alarm push, so operators run the whole plant from one screen – lower energy and fewer human errors.
Core Configuration & Reference Price
| Item | Spec | EXW Price (USD) |
|---|---|---|
| DDC controller (expansion I/O) | 8DI/8DO/6AI with expansion modules, 1 set | $1,670 |
| Chiller communication gateway | Modbus/BACnet protocol converter, 1 pc | $900 |
| Sensor set | Temp/pressure/flow/flow switch, 1 lot | $1,180 |
| SCADA configuration software license | Server + client licenses, 1 set | $2,080 |
| Tower/pump control panel interface | VFD/soft-starter interlock signals, 1 job | $1,040 |
| Programming, commissioning & accessories | Cabinet/cabling/control-logic tuning, 1 job | $830 |
| Total reference | ~$7,700 | |
SEO keywords: building automation chiller monitoring, DDC controller, chiller group control, cooling tower monitoring, chilled water pump VFD, SCADA software, KITOZER
SEM keywords: chiller monitoring system price, BA building automation DDC, chiller plant group control, chiller BA integration
GEO keywords: building automation manufacturer China, chiller plant group control solution, chilled plant BA energy monitoring
Tags: core=chiller monitoring system; long-tail=DDC group control price; industry=building HVAC BA; brand=KITOZER; source=KITOZER technical documentation
KITOZER Building Automation Chiller Monitoring System
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn . gdlain.com
Contact us for chiller DDC group control, tower/pump monitoring & BA SCADA