The KITOZER closed head foam fire suppression system is designed for flammable liquid hazards where water alone cannot extinguish or cool the fuel surface. The system stores foam concentrate in a bladder tank, mixes it with water at a controlled ratio, and delivers the resulting foam solution through closed-head sprinklers or foam chambers. The closed-head design means sprinklers are individually heat-activated, so only those over the fire operate, conserving foam concentrate and reducing water damage to surrounding areas. This approach is widely used in industrial and commercial hazards where flammable liquids are stored or processed.
Table of Contents
ToggleProduct Overview
The package includes a diaphragm bladder tank, foam concentrate, proportioner, control valve assembly, detection and release trim, and a network of closed-head foam sprinklers. When a sprinkler bulb ruptures, water flows through the proportioner, which draws foam concentrate from the bladder and injects it at the design ratio. The foam solution discharges through the open sprinkler, expands, and forms a sealing blanket over the fuel, suppressing vapor release and cooling the surface. The bladder design keeps concentrate separate from water until discharge, preserving shelf life.
Technical Specifications
Bladder tank sizes range from 200 to 5000 liters. Foam concentrate options include 3 percent or 6 percent aqueous film forming foam, fluoroprotein foam, or alcohol-resistant foam. Working pressure is 0.6 to 1.2 megapascals. Sprinkler ratings are typically 68 degrees Celsius bulb. Pipework is Schedule 40 or 80 steel. The system supports electric or pneumatic release trim and integrates with a KITOZER fire pump controller. The bladder is EPDM or nitrile compatible with the chosen concentrate.
Application Scenarios
Closed-head foam systems protect aircraft hangars, flammable liquid storage warehouses, paint mixing rooms, diesel generator rooms, transformer oil pits, loading docks, and industrial process areas handling hydrocarbons. They are also used in marine engine rooms and offshore modules where spill fires must be contained quickly. The system is suitable for both occupied and unoccupied areas, as foam discharge is less toxic than gaseous alternatives. It is also used in flammable liquid drum storage and racking areas.
Advantages
Foam provides rapid vapor suppression on liquid fuel fires and prevents re-ignition through cooling. Closed-head operation means only affected sprinklers open, reducing foam usage and cleanup. The bladder tank design ensures foam concentrate is never in contact with water until discharge, preserving shelf life. The system uses standard water-based pipework, which contractors know well. It is cost-effective for large hazards compared with gaseous total flooding. The foam blanket also shields adjacent fuel from radiant heat.
Installation and Maintenance
Install the bladder tank on a level concrete plinth with drainage and protective bunding. Route sprinkler pipework with suitable hangers and slope for drainage. Flush the pipework thoroughly before charging foam concentrate. After installation, perform a full flow test at the design pressure and verify the proportioning ratio. Inspect foam concentrate annually and replace per manufacturer shelf life, typically 3 to 10 years depending on type. Test sprinkler bulbs and control valves quarterly. Drain and flush the system after each discharge.
Engineering Notes
Choose alcohol-resistant foam for polar solvents such as alcohols, ketones, and esters, because regular foam breaks down on these fuels. Provide a dedicated water supply with sufficient flow and pressure for the design duration. Bundle the tank area to contain foam runoff. Coordinate with environmental authorities on foam discharge, because fluorosurfactant foams are regulated in some regions. Keep spare concentrate on site and date each batch. Test the proportioner annually with a refractometer.
Code and Compliance
Foam systems must be designed and installed under local foam standards and approved by the fire authority. Submit the hydraulic calculation, proportioning ratio, and foam concentrate specification for review. Provide enclosure drainage and bunding to contain foam runoff. Coordinate with environmental authorities on fluorosurfactant foam use. Annual inspection must include foam concentrate sampling and proportioner verification. Keep a log of concentrate batches and shelf life dates.
Detailed Application Examples
A 1000 square meter aircraft hangar uses a closed head foam system with a 2000L bladder tank and 40 foam sprinklers. The water supply is a dedicated fire pump with 2 hours duration. Alcohol-resistant foam is used because the hangar handles jet fuel. Annual proportioner tests verify the 3 percent mix, and foam concentrate is sampled yearly.
Price
From $6,800 for a 500L bladder tank package. Related accessories include spare bladder kits, proportioner cartridges, pressure gauges, deluge valves, foam chambers, and inspection test connections. KITOZER supplies compatible water motor alarms and pressure switch trim. The system, excluding field pipework. The system carries a two-year warranty on the bladder tank and trim. KITOZER supports proportioner verification, foam concentrate selection, and commissioning flow tests. Spare bladders, proportioner cartridges, and sprinkler bulbs are held in stock. Factory inspection is available for large installations. Contact +86 13922289957 for a complete foam system quotation.