KITOZER Cold Aisle Containment Double Row 42U Cabinet

Product Overview

The KITOZER Cold Aisle Containment Double Row 42U system encloses the aisle between two opposing rows of 42U server cabinets, turning the central cold corridor into a sealed plenum that receives conditioned air directly from perforated floor tiles or overhead ducts. This layout is the most common containment arrangement in medium data centers and delivers predictable thermal separation between supply and return air streams. The double-row configuration typically accommodates 12 to 24 cabinets across two rows, making it suitable for corporate data halls, colocation cages, cloud on-premise rooms, and enterprise IT centers running virtualization, storage area networks, and high-density compute clusters.

The KITOZER double-row containment uses the same anodized aluminum frame and clear polycarbonate roof as the single-row version but adds a central roof support rail when aisle length exceeds 12 meters. End-of-row sliding glass doors seal both ends of the cold aisle, and a roof-mounted pressure relief assembly prevents over-pressurization when CRAC units modulate or when the fire dampers close. The system can be delivered with either a floor-tile air supply design or an overhead duct supply design depending on the existing building services. KITOZER also provides CFD layout consultation so customers can see predicted hot spots before construction begins.

Technical Specifications

Cabinet size: 600mm x 1200mm x 2000mm (42U). Row count: 2 opposing rows. Aisle width: 1200mm standard, 1000 to 1500mm adjustable. Typical row length: 6 to 12 cabinets per row. Roof: 5mm clear polycarbonate panels on aluminum extrusions, center support rail for rows over 12m. End doors: automatic sliding tempered glass, dual doors at both aisle ends, infrared safety, adjustable speed. Pressure relief: top damper 0.3 square meter, threshold 5 to 20 Pa. Sealing: EPDM magnetic gaskets, brush strips under doors. Load rating: roof dead load 50 kg per square meter. Fire: UL 94 V-2 polycarbonate, tempered glass. Air leakage: less than 5 percent at 20 Pa. Power for door operator: 230V AC 50Hz, 60W. Communication: dry contact to BMS, optional RS485 Modbus. CE, RoHS, ISO 9001. KITOZER brand, 5 year structure warranty.

Applications

The double-row 42U cold aisle containment is deployed in corporate data centers, colocation cages, cloud on-premise rooms, banking core systems, insurance mainframe rooms, e-commerce data halls, government data service centers, and university high-performance computing clusters. It is also suitable for industrial automation centers running MES, SCADA, and historian servers, and for media production facilities running render farms and storage arrays. The sealed aisle allows operators to raise data hall ambient temperature to 27 to 30 degrees Celsius while keeping server inlets at 22 to 24 degrees Celsius, which aligns with ASHRAE A1 thermal guidelines and reduces cooling energy significantly. The system is also compatible with KITOZER in-row coolers for racks above 15 kW per cabinet.

Key Advantages

The principal advantage is strict thermal separation: cold supply air never mixes with hot exhaust, so CRAC units deliver exactly the airflow needed without over-cooling the entire room. This translates to 25 to 45 percent cooling energy savings, longer chiller life, and lower PUE. Second, hot spots are eliminated because every cabinet inlet receives uniform cold air, even in high-density racks over 10 kW per cabinet. Third, the double-row layout maximizes floor utilization by stacking cabinets back-to-back, leaving only one cold aisle and one hot return corridor. Fourth, the roof damper prevents pressure build-up and protects gasket integrity. Fifth, the transparent roof improves visibility for security cameras and simplifies cable inspection. Sixth, the sliding doors stay out of the walkway, unlike hinged doors that consume aisle clearance during opening. Seventh, the system can be extended bay-by-bay as the IT load grows.

Customization Options

Optional extras include LED aisle light bars with daylight sensors, roof-mounted cable tray supports, BMS monitoring for door state and damper position, emergency battery backup for 20 door cycles, tinted polycarbonate for glare control, and fire-rated EPDM gaskets rated to 120 degrees Celsius for hot aisle variants. Custom RAL colors are available for corporate branding. For colocation deployments, individual cage partitions and locked end doors can be integrated.

Installation and Maintenance

Installation is typically completed in 3 to 5 days for a 16-cabinet double-row layout. KITOZER recommends installing containment after cabinets are positioned and leveled. Crews fix roof brackets to cabinet tops, erect the aluminum frame, clip roof panels, install end sliding doors on both aisle ends, fit gaskets, and commission the pressure relief damper. A balancing contractor should measure aisle static pressure with a differential manometer and adjust the damper spring. After go-live, monthly visual inspection of gaskets and doors is recommended; annual rail lubrication, sensor test, and damper spring tension check should be scheduled. KITOZER supplies replacement polycarbonate panels, gasket rolls, door operators, and sensors from regional stock to minimize lead time during warranty service.

Price

From $8,600 per double-row containment kit (12 bays, roof, four sliding end doors, gaskets, two pressure dampers). Contact +86 13922289957 for project pricing based on cabinet count and aisle width.