KITOZER Cold Aisle Containment Double Row 47U High Density

Product Overview

The KITOZER Cold Aisle Containment Double Row 47U is a comprehensive thermal isolation solution for high-density enterprise data halls using 47U tall cabinets in a back-to-back arrangement. By sealing the cold aisle between two rows of tall cabinets, operators deliver conditioned air directly to server inlets while allowing hot exhaust to return freely to CRAC units through the open hot aisle. This layout is the industry reference design for modern data centers targeting PUE below 1.5. The system includes a reinforced aluminum roof frame, clear polycarbonate panels, automatic two-section sliding glass end doors, full-height magnetic gaskets, and oversized pressure relief dampers sized for the larger enclosed volume.

The double-row 47U configuration typically accommodates 12 to 24 cabinets in two rows and is suitable for enterprise data centers, colocation operators, cloud on-premise rooms, AI inference clusters, and high-performance computing facilities. KITOZER provides a complete thermal design package including airflow balancing calculations, CFD simulation references, and a commissioning checklist for the mechanical and electrical contractors. The reinforced roof also supports overhead cable trays, busbar trunking, and aisle lighting without additional structural columns. Delivery is packed in export plywood cases, with aluminum frames bundled, polycarbonate panels crated, and hardware bagged per bay for fast on-site identification.

Technical Specifications

Cabinet size: 600mm x 1200mm x 2200mm (47U). Aisle width: 1200mm standard, adjustable 1000 to 1500mm. Typical row: 6 to 12 cabinets per row. Roof: 5mm clear polycarbonate on reinforced aluminum frame, center support rail, load 80 kg per square meter. End doors: two-section tempered glass automatic sliding, infrared safety, 230V AC. Pressure relief: top dampers 0.3 square meter each, threshold 5 to 20 Pa. Gaskets: EPDM magnetic full-height. Air leakage: less than 5 percent at 20 Pa. Fire: UL 94 V-2 polycarbonate, tempered glass. Operating temp: 10 to 45 degrees Celsius. Communication: dry contact to BMS, optional Modbus. CE, RoHS, ISO 9001. KITOZER brand, 5 year structure warranty.

Applications

This double-row 47U containment is deployed in enterprise data centers, colocation cages, cloud on-premise rooms, AI inference and training clusters, HPC research labs, financial core processing centers, insurance data halls, government cloud service rooms, and hyperscale edge sites. It is also used in media render farms, broadcast playout centers, and large VDI deployments. The sealed aisle supports rack densities from 5 kW to 15 kW per cabinet without hot spots, and the open hot aisle simplifies connection to overhead hot-return ducted CRAC systems or rear-door heat exchangers. For AI clusters with GPUs that push rack density above 20 kW, KITOZER recommends pairing containment with rear-door water-cooled heat exchangers.

Key Advantages

The key advantage is high-density cooling efficiency: isolated cold air reaches every server inlet at 22 to 24 degrees Celsius while the hot aisle runs at 35 to 40 degrees Celsius, enabling CRAC units to operate at higher return temperatures and improved chiller efficiency. PUE typically drops from 2.0 to 1.3 to 1.5 after containment. Second, the reinforced roof supports heavy cable trays, PDUs, and aisle lights. Third, two-section sliding doors are safe for tall cabinets and provide clear visibility. Fourth, oversized dampers handle sudden fan speed changes. Fifth, the system is field-extensible: additional bays can be added without replacing end doors. Sixth, the transparent roof improves security camera coverage and reduces lighting energy. Seventh, the 47U height gives extra rack space for GPU servers and storage shelves.

Customization Options

Optional extras include roof-mounted cable tray supports rated to 150 kg, LED aisle light bars with daylight harvesting, BMS integration for door and damper telemetry, emergency battery backup for door operators, tinted polycarbonate for video projection rooms, and fire-rated EPDM gaskets. For colocation multi-tenant sites, individual cage partitions and RFID-controlled end doors can be integrated.

Installation and Maintenance

Installation takes 4 to 6 days for a 16-cabinet double-row layout. KITOZER recommends a lift for roof and glass handling. After cabinets are anchored, crews erect the aluminum frame, install polycarbonate panels, fit sliding end doors on both aisle ends, apply gaskets, mount dampers, and balance aisle static pressure. A differential manometer should be connected at mid-aisle during commissioning to verify damper opening. Maintenance includes monthly visual gasket inspection, quarterly door sensor test, semi-annual rail lubrication, and annual damper spring calibration. KITOZER supplies a commissioning report template and a remote acceptance review service for the customer and their consultant.

Warranty and Global Support

KITOZER backs every containment system with a 5-year structural warranty covering aluminum frames, polycarbonate panels, and glass doors, and a 1-year warranty on door operators and sensors. Spare parts including gasket rolls, door operators, infrared sensors, and damper springs are held in regional stock for next-day dispatch. KITOZER also provides remote commissioning support via video call, a detailed installation manual, and a dedicated project engineer for the duration of on-site work. Long-term maintenance contracts covering annual gasket inspection, sensor testing, and damper calibration are available for multi-site customers.

Price

From $9,400 per 12-bay double-row 47U containment kit (roof, four sliding end doors, gaskets, two dampers). Contact +86 13922289957 for project quotation.