KITOZER Combustible Gas Detector Methane LPG

The KITOZER combustible gas detector monitors the concentration of methane, LPG, propane, natural gas, or other combustible gases in air and triggers an alarm before the lower explosive limit is reached. The detector uses a catalytic bead or semiconductor sensor that changes resistance when exposed to combustible gas. It is installed in kitchens, boiler rooms, gas meter rooms, parking garages, and industrial gas handling areas to provide early warning of leaks and to trigger ventilation or gas shutoff valves.

Product Overview

The detector is a wall- or duct-mounted unit with a sensor head, an LCD showing gas concentration in percent LEL, and two alarm thresholds. Relay outputs trigger ventilation, shutoff valves, or sounders. The unit is powered by 24 volts DC and is available in standard or intrinsically safe versions for hazardous areas. A remote sensor head option allows installation in hard-to-reach locations.

Technical Specifications

Measuring range is 0 to 100 percent LEL. Alarm thresholds are 25 percent and 50 percent LEL, programmable. Sensor type is catalytic bead. Response time T90 is less than 30 seconds. Operating voltage is 24 volts DC. Relay outputs are two Form C at 2 amps. Analog output is 4 to 20 milliamps. Enclosure is IP54 or IP66. Operating temperature is -20 to 50 degrees Celsius. Sensor life is 2 to 3 years.

Application Scenarios

Combustible gas detectors are installed in commercial kitchens, gas boiler rooms, LPG storage rooms, chemical warehouses, battery charging rooms, underground parking garages, and industrial gas piping areas. They are also used in residential kitchens and boiler rooms where natural gas or LPG is used. The detector pairs with a gas shutoff valve and exhaust fan to automatically mitigate leaks.

Advantages

Continuous monitoring detects leaks before they reach explosive concentrations. Two alarm thresholds allow staged response: first alarm starts ventilation, second alarm closes the gas valve. Digital display gives operators concentration readout. Relay outputs automate mitigation. Catalytic bead sensors are reliable and widely accepted. Intrinsically safe versions suit Zone 1 and 2 hazardous areas.

Installation and Maintenance

Install detectors at the correct height: near the ceiling for lighter-than-air gases such as methane, near the floor for heavier-than-air gases such as LPG. Keep the sensor head unobstructed. Calibrate every 6 to 12 months with certified test gas. Bump test monthly. Replace the sensor every 2 to 3 years or when calibration fails. Inspect enclosure and cable glands annually. Keep the sensor free of silicone, solvents, and dust.

Engineering Notes

Install detectors at the correct height for the gas density. Calibrate every 6 to 12 months with test gas. Bump test monthly. Keep sensors free of silicone and solvents. Interlock with gas shutoff and ventilation. Use intrinsically safe versions in hazardous areas.

Code and Compliance

Gas detectors must comply with local combustible gas detector standards. Submit the detector layout and alarm thresholds for approval. Annual calibration records must be kept. Replace sensors at rated life. Keep a calibration log on site.

Warranty and Accessories

From $280 per combustible gas detector. The detector carries a two-year warranty. KITOZER supplies catalytic bead and NDIR versions, plus intrinsically safe and duct-mounted models. Spare sensors and calibration kits are available. Contact +86 13922289957 for intrinsically safe versions.

Detailed Application Examples

Three combustible gas detectors cover a gas boiler room, mounted near the ceiling for methane. At 25 percent LEL, ventilation starts; at 50 percent LEL, the gas shutoff valve closes. Each detector is calibrated every 6 months with test gas. Sensors are replaced every 3 years.

Long-term Operational Benefits

Combustible gas detectors require periodic sensor replacement every 3 years, but the controller body lasts much longer. Because they trigger ventilation and shutoff automatically, they prevent gas accumulation before it reaches explosive levels. The digital display gives operators immediate concentration readout. Calibration with test gas is straightforward. A two-year warranty covers the electronics.

System Integration

Combustible gas detectors wire to the gas panel or fire panel with alarm and fault relays. At first alarm, ventilation starts; at second alarm, the gas shutoff valve closes. The 4 to 20 milliamp output gives continuous concentration readout on the building management system. Calibration status is also reported, so the panel knows when service is due. This makes the system part of the overall safety interlock.

Why Choose KITOZER

KITOZER gas detectors are built for combustible gas monitoring and backed by factory support. Each detector is calibrated before shipment. KITOZER supplies calibration gas, sensors, and shutoff valve interlocks as a complete package, ensuring safe operation.

Summary

In summary, the combustible gas detector provides continuous monitoring that triggers ventilation and shutoff before explosive levels are reached. Its digital display and relay outputs integrate with building management. KITOZER supplies the detector with a two-year warranty and supports intrinsically safe versions.