Computer Room Cable Tray System | KITOZER

Engineering verification notice: Cable-tray type, material, load rating, coating, grounding resistance, seismic accessories and cited standards are project-specific. Final values require an approved data sheet and formal quotation.

Table of Contents

Metal Tray Models and Material Options

This page now consolidates the computer-room cable-tray solution with the former metal-tray specification page. Series such as enclosed, semi-enclosed, partitioned, top-of-rack and under-rack trays, plus stainless-steel and powder-coated options, should be selected from the current project bill of materials.

1. System Introduction

1.1 Definition and Core Value

The KITOZER computer room cable tray system is a cable support and management system specially designed for critical information infrastructures such as data centers, computer rooms and server rooms, serving as a core component of computer room cabling. Acting as the “expressway” for cables, it provides safe and reliable routing for power cables, communication cables, optical fibers and other lines. It realizes core values including separation of strong and weak current, layered management, efficient heat dissipation and convenient maintenance, and is an essential infrastructure to guarantee stable operation of computer rooms.

1.2 Design Concept & Technical Standards

Adhering to the design philosophy of Safety & Reliability, Flexibility & Efficiency, Energy Conservation & Environmental Protection, Intelligent Management, the KITOZER cable tray system strictly complies with the following specifications:

  • T/CECS 31-2017 Technical Specification for Steel Cable Tray Engineering
  • GB 50174-2017 Code for Design of Data Centers
  • GB 50311-2016 Code for Engineering Design of Generic Cabling Systems
  • IEC 61537 International Standard for Cable Management Systems
data center cable tray solution 1 (9)

2. System Composition

The KITOZER cable tray system consists of five core components that work collaboratively to form a complete cable management solution.

System ComponentCore PartsFunction Description
Cable Tray BodyStraight sections, horizontal/vertical elbows, tees, crosses, reducing jointsServe as the main routing for cables and adapt to various route changes
Support SystemUprights, brackets, hangers, supports, seismic connectorsBear the weight of trays and cables, ensure firm installation and deliver seismic resistance
Partition SystemPartition plates, dividers, grounding copper barsSeparate strong and weak current circuits, reduce electromagnetic interference and ensure signal transmission quality
Protection SystemCovers, dust shields, fire barriers, grounding wiresProvide physical protection, dustproofing, fire resistance and earthing protection
Accessory SystemConnection plates, bolts, nuts, expansion screws, nameplatesEnsure tight connection of all components and facilitate installation, maintenance and management

3. System Classification

3.1 Classification by Structural Type

TypeStructural FeaturesApplication Scenarios
Solid Bottom TrayFully enclosed structure with integrated side plates and base, configurable with coversWeak current systems, sensitive signal lines, dust-proof and moisture-proof environments
Perforated TraySemi-enclosed structure with 30%~40% open holes at the bottom and closed side platesMixed laying of power and data cables, scenarios requiring high heat dissipation
Ladder TrayOpen structure composed of two longitudinal beams and horizontal rungs (spacing: 300-500mm)Large-section power cables, high-load cables and high-temperature environments
Wire Mesh TrayWelded steel wire mesh with fully open designHigh-density cabling in data centers, network environments with frequent layout changes
Combined TrayFlexible combined structure supporting multi-layer stackingComplex computer room layouts and high-density cabling in limited spaces

3.2 Classification by Material

MaterialSurface TreatmentPerformance FeaturesApplication Environment
Steel TrayHot-dip galvanizing, electro-galvanizing, powder coating, fire-retardant coatingHigh strength and strong load-bearing capacityGeneral computer rooms and power cable systems
Aluminum Alloy TrayAnodization, powder coatingLight weight, corrosion resistance and good heat dissipationCorrosive environments, ceiling mounting and long-span installation
Stainless Steel Tray304 / 316L stainless steelExcellent corrosion resistance and long service lifeCoastal computer rooms, chemical environments and clean rooms
FRP TrayResin & glass fiber compositeSuperior insulation, corrosion resistance and light weightHighly corrosive environments and outdoor installation

3.3 Classification by Functional Features

TypeCore FeaturesApplication Scenarios
Fire-resistant TrayDouble-layer structure filled with fireproof rock wool (density ≥100kg/m³), excellent flame retardancyFire protection systems, emergency power lines and key computer rooms
Seismic TrayEquipped with seismic connectors, compliant with GB 50981 seismic standardEarthquake-prone areas, major data centers and financial computer rooms
Energy-saving TrayOpen structure with optimized heat dissipation to reduce air conditioning power consumptionHigh-density data centers and green energy-saving computer rooms
Intelligent TrayIntegrated temperature sensors, smoke detectors and optical fiber link monitorsIntelligent data centers and key computer rooms requiring real-time monitoring

3.4 Classification by Load Grade

Load GradeLoad CapacityWall Thickness RequirementApplication Scenarios
Light-duty≤50kg/m1.0-1.2mmWeak current cables and small-section signal lines
Medium-duty50-150kg/m1.5-2.0mmMixed laying of conventional power and data cables
Heavy-duty≥150kg/m2.5-3.0mmLarge-section power cables, high-load computer rooms and long-span installation
data center cable tray solution 1 (8)

4. System Configuration List (Brand: KITOZER)

4.1 Standard Configuration for Small & Medium-Sized Computer Rooms

No.Product NameModel & SpecificationUnitRemarks
I. Cable Tray Body
1Solid Bottom Straight TrayKT-C-100×50MeterSteel, hot-dip galvanized, 1.5mm thickness
2Solid Bottom Straight TrayKT-C-200×100MeterSteel, hot-dip galvanized, 1.5mm thickness
3Solid Bottom Horizontal ElbowKT-C-100×50-90°PieceSteel, hot-dip galvanized
4Solid Bottom Horizontal ElbowKT-C-200×100-90°PieceSteel, hot-dip galvanized
5Solid Bottom TeeKT-C-200×100-TPieceSteel, hot-dip galvanized
6Perforated Straight TrayKT-P-300×100MeterSteel, hot-dip galvanized, 35% bottom opening rate
7Ladder Straight TrayKT-T-400×150MeterSteel, hot-dip galvanized, rung spacing: 300mm
8Wire Mesh Straight TrayKT-M-150×100Meter4mm steel wire, hot-dip galvanized
II. Support System
9Upright PostKT-S-3000PieceSteel, hot-dip galvanized, 3m height
10Bracket ArmKT-A-200PieceSteel, hot-dip galvanized, 200mm length
11HangerKT-H-100PieceSteel, hot-dip galvanized, for 100mm wide tray
12Seismic ConnectorKT-E-01SetCompliant with GB 50981 standard
III. Partition & Protection System
13Partition PlateKT-D-200MeterSteel, for 200mm wide tray
14Tray CoverKT-CV-100×50MeterSteel, for 100×50 solid bottom tray
15Grounding Copper BarKT-G-30×3MeterRed copper, 3mm thickness
IV. Accessory System
16Connection PlateKT-J-100SetFor 100mm wide tray
17Bolt & NutKT-B-8×25SetStainless steel
18NameplateKT-L-01PieceHandwritten/printable for line identification

4.2 Custom Configuration Instructions

KITOZER provides full-range customization services to meet on-site demands:

  • Special Sizes: Width 50-1200mm, height 30-300mm, customizable length
  • Special Materials: 316L stainless steel, aluminum alloy, FRP and more
  • Special Treatments: Fire-retardant coating, anti-static treatment, enhanced anti-corrosion treatment
  • Special Structures: Multi-layer stacking, special-shaped elbows, long-span design (max. 6m)
data center cable tray solution 1 (7)

5. System Schematic Diagrams

5.1 Topology Diagram of Computer Room Cable Trays

[Computer Room Entrance]
|
├─[Main Ladder Tray (400mm width)]────┬─[Server Area Perforated Tray (300mm width)]─────┬─[Cabinet Row 1]
| | ├─[Cabinet Row 2]
| | └─[Cabinet Row 3]
| |
| ├─[Network Area Solid Bottom Tray (200mm width)]───────┬─[Switch Cabinet 1]
| | ├─[Switch Cabinet 2]
| | └─[Optical Fiber Distribution Frame]
| |
| └─[Storage Area Wire Mesh Tray (150mm width)]─────┬─[Storage Cabinet 1]
| └─[Storage Cabinet 2]
|
└─[Spare Expansion Tray]─────────────────────────────────────────────[Reserved Area]

5.2 Schematic for Separate Laying of Strong & Weak Current

[Upper Layer: Ladder Tray for Power Circuits] — 380V power cables, UPS output cables
|
├─[Partition Plate] — Vertical spacing ≥ 300mm
|
[Middle Layer: Perforated Tray for Lighting & Control Circuits] — 220V lighting cables, control cables
|
├─[Partition Plate] — Vertical spacing ≥ 200mm
|
[Lower Layer: Solid Bottom / Wire Mesh Tray for Weak Current] — Network cables, optical fibers, communication cables
|
└─[Grounding Copper Bar] — Full-length earthing for electromagnetic shielding

5.3 Schematic of Seismic Support System

[Ceiling / Floor Slab]
|
├─[Expansion Bolt]
|
├─[Seismic Hanger] — Absorb horizontal and vertical seismic force
| |
| ├─[Seismic Connector] — Allow proper displacement
| |
├─────┴─[Cable Tray Body]
|
├─[Horizontal Seismic Bracket] — Prevent horizontal shaking
|
└─[Upright Support] — Floor mounting for vertical bearing

data center cable tray solution 1 (5)

6. Product Technical Parameters

6.1 General Technical Parameters

Parameter CategoryTechnical ItemKITOZER StandardTest Standard
Material PerformanceBase MaterialQ235B Cold-rolled SteelGB/T 700
Hot-dip Galvanized Coating Thickness≥86μmGB/T 13912
Salt Spray TestNo rust within 2000 hoursASTM B117
Aluminum Alloy Grade6063-T5GB/T 3190
Structural PerformanceLoad CapacityLight-duty: ≤50kg/mMedium-duty: 50-150kg/mHeavy-duty: ≥150kg/mT/CECS 31-2017
Span LengthStandard: 1.5-3mMax. Custom Span: 6mT/CECS 31-2017
Seismic GradeFortified for Magnitude 9 EarthquakeGB 50981
Fire Resistance (Fire-rated Tray)Fire endurance ≥120 minutesGB 23864
Electrical PerformanceGrounding Resistance≤0.1ΩGB 50169
Insulation Resistance≥100MΩGB/T 16906
Shielding Effectiveness (Solid Bottom Tray)≥60dBGB/T 12190
Environmental AdaptabilityOperating Temperature-40℃ ~ +80℃IEC 60068
Ingress ProtectionWith cover: IP40Basic type: IP20GB 4208

6.2 Detailed Parameters of Each Tray Type

6.2.1 Solid Bottom Tray (KT-C Series)

ModelWidth × Height (mm)Wall Thickness (mm)Load Capacity (kg/m)Cable Accommodation
KT-C-100×50100×501.2/1.550/8024 Cat.6 network cables or 6 power cables
KT-C-200×100200×1001.5/2.080/12048 Cat.6 network cables or 12 power cables
KT-C-300×150300×1502.012072 Cat.6 network cables or 18 power cables
KT-C-400×200400×2002.0/2.5150/20096 Cat.6 network cables or 24 power cables

6.2.2 Perforated Tray (KT-P Series)

ModelWidth × Height (mm)Wall Thickness (mm)Opening RateLoad Capacity (kg/m)
KT-P-200×100200×1001.535%100
KT-P-300×150300×1502.035%150
KT-P-400×200400×2002.035%200
KT-P-500×200500×2002.535%250

6.2.3 Ladder Tray (KT-T Series)

ModelWidth × Height (mm)Wall Thickness (mm)Rung Spacing (mm)Load Capacity (kg/m)
KT-T-300×150300×1502.0300200
KT-T-400×200400×2002.0300250
KT-T-500×200500×2002.5300300
KT-T-600×200600×2002.5300350

6.2.4 Wire Mesh Tray (KT-M Series)

ModelWidth × Height (mm)Wire Diameter (mm)Mesh Size (mm)Load Capacity (kg/m)
KT-M-100×50100×503.530×3040
KT-M-150×100150×1004.030×3060
KT-M-200×100200×1004.030×3080
KT-M-300×150300×1504.530×30100
data center cable tray solution 1 (3)

7. Application Scope

The KITOZER cable tray system is widely applied in the following scenarios:

7.1 Data Centers & Computer Rooms

  • Large cloud computing data centers, financial data centers, Internet Data Centers (IDC)
  • Enterprise server rooms, network rooms and storage rooms
  • Edge computing nodes and miniature data centers

7.2 Communication & Network Infrastructure

  • Telecommunication rooms, mobile base stations and communication hubs
  • Network Operation Centers (NOC) and data control centers
  • FTTH rooms and broadband access rooms

7.3 Enterprise & Institutional Computer Rooms

  • Computer rooms of government authorities, financial institutions, medical and educational organizations
  • Control rooms for energy, manufacturing and transportation industries
  • Weak current rooms in commercial complexes and high-grade office buildings

7.4 Special Environments

  • Industrial automatic control rooms and explosion-proof rooms
  • Offshore platforms, chemical parks and highly corrosive environments
  • Computer rooms for military, aerospace and scientific research with special requirements
data center cable tray solution 1 (2)

8. Product Advantages

8.1 Safety & Reliability for Stable Operation

  • High-strength structure: Adopt premium cold-rolled steel with uniform wall thickness; maximum load capacity reaches 350kg/m, far exceeding industry standards.
  • All-round protection: Equipped with fireproof, dustproof, moisture-proof and seismic functions, complying with GB 50174-2017.
  • Reliable earthing: Complete earthing design with grounding resistance ≤0.1Ω to prevent static accumulation and electromagnetic interference.

8.2 Flexibility & Efficiency for Complex Environments

  • Modular design: Standardized components enable rapid assembly and fit various route layouts.
  • Layered management: Support separate laying of strong and weak current with vertical spacing ≥300mm to reduce signal interference.
  • Easy expansion: Open structure facilitates cable addition; wire mesh trays support plug-and-play cabling adjustment.

8.3 Energy Saving & Low Operating Cost

  • Excellent heat dissipation: Open structure of perforated and wire mesh trays improves heat dissipation efficiency by 40%, reduces air conditioning consumption and optimizes PUE by 0.15.
  • Lightweight design: Aluminum alloy and wire mesh trays lower building load and installation cost.
  • Long service life: Hot-dip galvanized surface passes 2000-hour salt spray test; service life exceeds 15 years to cut replacement frequency.

8.4 Intelligent Management to Improve O&M Efficiency

  • Visual management: Open trays simplify cable inspection and troubleshooting, cutting maintenance time by over 50%.
  • Complete marking system: Support full-lifecycle cable management with matched nameplates.
  • Intelligent expansion: Compatible with temperature sensors, optical fiber monitors and other smart modules for remote monitoring.

8.5 Customized Service for Special Demands

  • Full-size customization: Width 50~1200mm, height 30~300mm available on request.
  • Diverse materials: Stainless steel, aluminum alloy, FRP and other options for different corrosive environments.
  • Special structures: Custom long-span trays (max. 6m), special elbows and multi-layer stacked structures.

9. Bid Control Parameters

9.1 Core Technical Parameters (for tender documents)

9.1.1 General Requirements

  1. Material: Made of Q235B premium cold-rolled steel complying with GB/T 700; tensile strength ≥370MPa, yield strength ≥235MPa.
  2. Surface treatment: Hot-dip galvanized coating thickness ≥86μm (GB/T 13912); no rust after 2000-hour salt spray test.
  3. Load capacity: Medium-duty tray (1.5mm wall) ≥80kg/m; heavy-duty tray (2.0mm wall) ≥120kg/m.
  4. Fire resistance: Fire-rated tray fire endurance ≥120 minutes (GB 23864); density of filled fireproof rock wool ≥100kg/m³.
  5. Seismic performance: Compliant with GB 50981, fortified for Magnitude 9 earthquake; seismic connectors allow horizontal displacement of ±20mm.
  6. Earthing performance: Connection resistance between trays ≤0.0003Ω; system grounding resistance ≤0.1Ω (GB 50169).

9.1.2 Special Parameters for Each Tray Type

Solid Bottom Tray

  • Fully enclosed structure with integrated side plates and base, no welding gaps.
  • Gap between cover and tray body ≤1mm, firm and flat after installation.
  • Shielding effectiveness ≥60dB for sensitive signal transmission.

Perforated Tray

  • Bottom opening rate 30%~40% with evenly arranged strip holes.
  • Smooth hole edges without burrs to avoid cable sheath damage.
  • Side plate height ≥50mm for sufficient protection.

Ladder Tray

  • Rung spacing 300mm; connected by TOX riveting or integral forming without loose risk.
  • Connection strength between longitudinal beam and rung ≥500N for stable load bearing.
  • Open design for easy heat dissipation and maintenance.

Wire Mesh Tray

  • Steel wire diameter ≥4mm, mesh size 30×30mm with firm welding.
  • Uniform surface treatment, no missing or virtual welding.
  • High installation flexibility for 360° cabling in any direction.

9.2 Commercial Bid Requirements

  1. Provide ISO9001 Quality Management System and ISO14001 Environmental Management System certificates.
  2. Submit test reports issued by national-level testing institutions covering load capacity, fire resistance and earthing performance.
  3. Offer no less than 3 similar project cases (contract amount ≥ 500,000 RMB) with user contact information.
  4. Warranty period ≥5 years; provide after-sales service commitment: 24-hour response and on-site service within 48 hours.
  5. Prove independent production capacity with factory scale, equipment list and production capacity documents.

10. Product Solutions

10.1 Solution for Small & Medium-Sized Enterprise Computer Rooms

10.1.1 Overview

For 200-500㎡ computer rooms of small and medium-sized enterprises, adopt a three-layer tray structure + modular management scheme to realize separation of strong and weak current, efficient heat dissipation and easy maintenance.

10.1.2 Design

  1. Topology: Main route uses 400mm wide ladder tray for power cables and UPS output; branch routes adopt 200mm wide perforated tray for server power lines; 150mm wide wire mesh tray for network cables and optical fibers.
  2. Layered Layout:
    • Upper layer (3.0m above ground): Ladder tray for 380V power cables and UPS lines
    • Middle layer (2.5m above ground): Perforated tray for 220V server power cables and air conditioning control lines
    • Lower layer (2.0m above ground): Wire mesh tray for Cat.6 network cables and optical fibers
    • Vertical spacing between layers ≥500mm with partition plates to reduce electromagnetic interference
  3. Support System: No.10 channel steel uprights with 1.5m spacing for floor fixing; L-type angle steel brackets matching tray width; seismic connectors installed at key positions.

10.1.3 Advantages

  • Cost-effective: Adopt economical materials, total investment reduced by 15% compared with traditional schemes.
  • Fast installation: Modular design shortens construction period by 30%.
  • Easy maintenance: Wire mesh tray simplifies line inspection and expansion.
  • Good scalability: 20% reserved space to support business growth.

10.2 High-Density Cabling Solution for Large Data Centers

10.2.1 Overview

For data centers over 1000㎡, apply multi-layer combined tray + intelligent management to meet high-density, high-bandwidth and high-reliability cabling demands.

10.2.2 Design

  1. High-density Structure: Combined trays with 100mm layer height, stackable for 3~5 layers vertically; partition plates for physical isolation of power and signal cables; single tray holds 120 Cat.6 cables or 24 power cables, space utilization increased by 200%.
  2. Intelligent Management: Integrated temperature sensors for over-temperature automatic alarm; QR code-based intelligent marking for full-lifecycle cable management; linked with room monitoring system for remote monitoring and early warning.
  3. Heat Dissipation Optimization: Combined wire mesh and perforated trays for higher heat dissipation; layout optimized via CFD simulation to lower cable surface temperature by 10℃ and optimize PUE by 0.15; align trays with air outlets to form cold air circulation.
  4. Redundancy Design: Separated main and standby trays with dual routing for key lines; dual earthing design for higher safety; double upright support to raise load capacity by 50%.

10.2.3 Advantages

  • Ultra-high density: Cabling density per square meter reaches 3 times of traditional solutions.
  • Superior heat dissipation: Heat dissipation efficiency improved by 40% to cut air conditioning cost.
  • Intelligent O&M: Troubleshooting time reduced by 80% via real-time monitoring.
  • High reliability: Redundant design ensures system availability up to 99.999%.

10.3 Solution for Highly Corrosive Environments

10.3.1 Overview

Adopt stainless steel + FRP composite trays for computer rooms in coastal areas, chemical parks and other highly corrosive environments to extend service life.

10.3.2 Design

  1. Material Selection: 316L stainless steel trays for outdoor sections to resist chloride corrosion; FRP trays for indoor sections with good insulation and light weight; all connecting parts made of stainless steel to avoid contact corrosion.
  2. Surface Treatment: Polished stainless steel surface for better corrosion resistance; weather-resistant resin with UV absorber for FRP trays; all fasteners use stainless steel.
  3. Protection Measures: Seal tray joints with sealant to prevent moisture ingress; install rain shields for outdoor use; formulate regular maintenance plans to extend service life over 20 years.

10.3.3 Advantages

  • Outstanding corrosion resistance: Adapt to high salt spray and high humidity environments; service life doubled compared with ordinary trays.
  • Good insulation: FRP tray insulation resistance ≥100MΩ, suitable for high-voltage environments.
  • Light weight: 40% lighter than steel trays to reduce load on support system.
  • Low maintenance cost: Almost maintenance-free, long-term operating cost reduced by 50%.

11. Project Cases

11.1 Case 1: Financial Data Center Project

11.1.1 Project Profile

  • Project: Data Center Expansion Project of XX Bank Head Office
  • Scale: 2000㎡, 500 cabinets, power density: 8kW per cabinet
  • Period: March ~ June 2025
  • Solution: High-density cabling solution for large data centers

11.1.2 Applied Products

  • Main tray: KT-T-600×200 heavy-duty ladder tray for power cables
  • Branch tray: KT-P-300×150 perforated tray for server power lines
  • Weak current tray: KT-M-200×100 wire mesh tray for Cat.6 cables and optical fibers
  • Support system: No.12 channel steel uprights (1.2m spacing) and seismic connectors
  • Partition system: Three layers of partition plates for strong/weak current separation

11.1.3 Project Effect

  • Cabling density increased to 2.5 times of traditional schemes; single tray holds 120 Cat.6 cables.
  • Heat dissipation efficiency improved by 40%; room PUE dropped from 1.8 to 1.65, saving about 800,000 RMB in electricity fees annually.
  • System stability enhanced, failure rate reduced by 60%.
  • Maintenance efficiency raised, line checking time shortened by 70%.

11.2 Case 2: Edge Computing Node Project of Internet Company

11.2.1 Project Profile

  • Project: National Edge Computing Node Construction Project of XX Internet Company
  • Scale: 30 nodes, 50㎡ & 20 cabinets per node
  • Period: May ~ October 2025
  • Solution: Small & medium-sized computer room solution with high-reliability design

11.2.2 Applied Products

  • Main tray: KT-C-400×200 solid bottom tray for power and control cables
  • Branch tray: KT-M-150×100 wire mesh tray for network cables
  • Support system: No.8 channel steel uprights (1.5m spacing) for floor fixing
  • Protection system: Fireproof covers and seismic connectors

11.2.3 Project Effect

  • Standardized deployment for 30 nodes, construction period shortened by 40%.
  • Cost controlled, total investment reduced by 20%.
  • High reliability to meet unattended operation requirements of edge nodes.
  • 50% reserved expansion space to support rapid business growth.

11.3 Case 3: Control Room Project of Chemical Park

11.3.1 Project Profile

  • Project: Central Control Room Construction of XX Chemical Park
  • Scale: 800㎡, 100 cabinets, highly corrosive environment
  • Period: February ~ May 2025
  • Solution: Solution for highly corrosive environments

11.3.2 Applied Products

  • Outdoor tray: KT-SS-300×150 316L stainless steel tray
  • Indoor tray: KT-FRP-200×100 FRP tray
  • Support system: Stainless steel uprights and brackets
  • Protection system: Sealed covers and rain shields

11.3.3 Project Effect

  • Excellent corrosion resistance adapting to high salt spray environment of chemical parks.
  • Service life extended to 20 years, long-term cost reduced by 60%.
  • Good insulation performance suitable for high-voltage environment in chemical parks.
  • Low maintenance workload and reduced operating cost.

12. Search Keywords & SEO Tags

12.1 Core Keywords

Computer room cable tray solution, KITOZER cable tray, data center cable tray system, computer room cabling tray, strong & weak current separation tray, high-density cabling tray, wire mesh tray application, fire-resistant & seismic cable tray

12.2 SEO Long-tail Keywords

Computer room cable tray system design, data center cable tray selection, computer room cabling specification, cable tray installation standard, technical parameters of cable tray, cable tray brand recommendation, advantages of KITOZER tray, cable tray solution cases

12.3 Tags

#ComputerRoomCableTray #DataCenterCabling #CableManagement #KITOZER #StrongWeakCurrentSeparation #HighDensityCabling #FireResistantTray #SeismicTray #WireMeshTray #ComputerRoomConstruction