The KITOZER computer room cabling and patch panel system is a professional cabling management solution independently developed by Guangzhou Lai’an Intelligent System Development Co., Ltd. As a core management component of the structured cabling system, it undertakes the cross-connection function of the horizontal subsystem and the vertical backbone subsystem, and serves as the nerve center for network signal transmission in computer rooms. Adopting a modular design concept, the system is compatible with both copper and optical fiber transmission media, and fully supports copper cable grades from Cat5e to Cat8 as well as optical fiber types including OM3/OM4/OS2. It provides an efficient, reliable and scalable cabling management platform for data centers, computer rooms and various network environments.
Compliant with international standards such as ISO/IEC 11801 and TIA-568-C.2, the system features high density, intelligence and easy maintenance. It can meet the diverse scale requirements from small and medium-sized enterprise computer rooms to large cloud data centers, realize the standardized and normalized management of network cabling, significantly improve operation and maintenance efficiency and reduce the total cost of ownership (TCO).
II. System Composition
The KITOZER computer room cabling and patch panel system consists of the following core components, forming a complete cabling management ecosystem:
| Component Category | Core Products | Function Description |
|---|---|---|
| Patch Panel Main Unit | Copper patch panels (Cat5e/Cat6/Cat6a/Cat7/Cat8)<br>Optical fiber patch panels (SC/LC/MPO/ST)<br>Hybrid media patch panels (fiber + copper) | Provide signal termination and cross-connect functions, support different transmission media and rate requirements |
| Connection Module | Copper modules (RJ45)<br>Fiber optic adapters (simplex/duplex)<br>MPO cassettes | Achieve physical connection between cables and device ports, support hot-swappable replacement |
| Cable Management | Cable managers (horizontal/vertical)<br>Cable organizers<br>Identification system (labels/identification strips) | Optimize cable routing, reduce signal interference, facilitate maintenance and identification |
| Installation Accessories | 19-inch standard rack<br>Installation guide rails<br>Grounding kit<br>Dust cover | Ensure stable installation of patch panels, provide physical protection and electromagnetic shielding |
| Intelligent Management Components | Electronic labels<br>Port sensors<br>Intelligent management software | Realize real-time monitoring of port connection status, support remote management and fault early warning |
| Auxiliary Materials | Jumpers (copper/optical fiber)<br>Pigtails<br>Couplers<br>Cable ties/fixtures | Ensure complete system connection, optimize signal transmission paths |
III. System Classification
The KITOZER computer room cabling and patch panel system is classified according to different dimensions to meet the needs of diverse application scenarios:
3.1 Classification by Transmission Medium
系统解决方案6-1024x575.jpg)
| Category | Model Series | Technical Features | Applicable Scenarios |
|---|---|---|---|
| Copper Patch Panel | K-PP-CU Series | Supports Cat5e~Cat8 copper cables, RJ45 interfaces, punch-down/tool-less termination | Data networks, voice communication, monitoring systems |
| Optical Fiber Patch Panel | K-PP-FO Series | Supports single-mode/multi-mode optical fibers, SC/LC/MPO interfaces, high-density design | High-speed data transmission, long-distance communication, data center interconnection |
| Hybrid Patch Panel | K-PP-HY Series | Integrates copper and optical fiber ports, supports hybrid fiber + copper deployment | Edge computing, converged communication, IoT device access |
3.2 Classification by Installation Method
- Rack-mount patch panel: 19-inch standard width, 1U/2U height, suitable for standard cabinet installation, supports high-density port configuration (up to 48 ports/1U for copper, 96 cores/1U for optical fiber)
- Wall-mount patch panel: Suitable for small computer rooms or weak current rooms with limited space, supports independent installation or wall-mounted cabinet deployment
- Embedded patch panel: Custom-designed for integrated cabinets, seamlessly integrated into the internal structure of cabinets to optimize space utilization
3.3 Classification by Management Method
- Traditional patch panel: Manual management, identify port connection status through physical labels, cost-effective, suitable for small-scale network environments
- Intelligent patch panel: Integrates electronic labels and sensors, supports real-time monitoring of port connection status, realizes automated operation and maintenance with supporting management software, and reduces human error rate
- High-density intelligent patch panel: Supports more than 48 copper ports or 144 optical fiber cores per 1U, integrates intelligent management functions, suitable for high-density deployment requirements of large data centers
3.4 Classification by Shielding Characteristic
- Unshielded patch panel (UTP): Suitable for general office environments, cost-effective and easy to install
- Shielded patch panel (FTP/STP): Has good electromagnetic interference (EMI) protection capability, suitable for high-interference scenarios such as industrial environments and financial transaction centers
- Enhanced shielded patch panel (SFTP): Double-layer shielding structure, provides higher electromagnetic compatibility, meets the needs of special industries such as military and medical care
IV. System Configuration List (KITOZER Brand)
The following are standard configuration lists for computer rooms of different scales, which can be flexibly adjusted according to actual needs:
4.1 Configuration List for Small and Medium-Sized Enterprise Computer Rooms (within 200 points)
系统解决方案5-1024x575.jpg)
| Product Name | Model | Specifications | Quantity |
|---|---|---|---|
| Copper Patch Panel | K-PP-CU6-24 | Cat6 unshielded, 24 ports, 1U, RJ45 ports, punch-down | 8 pcs |
| K-PP-CU6A-48 | Cat6a unshielded, 48 ports, 1U, tool-less | 2 pcs | |
| Optical Fiber Patch Panel | K-PP-FO-LC-24 | 24-port LC duplex, single-mode/multi-mode compatible, 1U | 2 pcs |
| Cable Manager | K-CM-1U | 1U horizontal cable manager, metal material | 12 pcs |
| Copper Module | K-MOD-CU6 | Cat6 unshielded RJ45 module | 200 pcs |
| Fiber Optic Adapter | K-ADA-LC-DX | LC duplex adapter, ceramic sleeve | 48 pcs |
| Grounding Kit | K-GND-SET | Special grounding component for patch panels | 12 sets |
| Identification System | K-LABEL-KIT | Port labels + identification strips + printer | 2 sets |
| Jumper | K-JUMP-CU6-2M | Cat6 unshielded jumper, 2m | 200 pcs |
| K-JUMP-LC-SM-3M | LC-LC single-mode fiber jumper, 3m | 48 pcs |
4.2 Configuration List for Large Data Centers (more than 1000 points)
| Product Name | Model | Specifications | Quantity |
|---|---|---|---|
| High-Density Copper Patch Panel | K-PP-CU6A-48HD | Cat6a shielded, 48 ports, 1U, high-density design | 20 pcs |
| K-PP-CU8-24 | Cat8 shielded, 24 ports, 1U, supports 40Gbps | 10 pcs | |
| MPO Fiber Patch Panel | K-PP-FO-MPO-12 | 12-port MPO, supports 144 cores, 1U | 10 pcs |
| Intelligent Management Unit | K-IMU-48 | 48-port intelligent management module, electronic label | 20 pcs |
| Vertical Cable Manager | K-CM-VERT-4U | 4U vertical cable manager, high-density cable management | 10 pcs |
| Copper Module | K-MOD-CU6A-SFTP | Cat6a shielded module | 800 pcs |
| K-MOD-CU8 | Cat8 shielded module | 200 pcs | |
| MPO Cassette | K-MPO-BOX-12 | 12-core MPO cassette | 100 pcs |
| Intelligent Management Software | K-IMS-V3.0 | Port monitoring + asset management + fault early warning | 1 set |
| Jumper | K-JUMP-CU6A-SFTP-1M | Cat6a shielded jumper, 1m | 800 pcs |
| K-JUMP-MPO-12-5M | MPO-MPO 12-core fiber jumper, 5m | 100 pcs |
V. System Schematic Diagrams
系统解决方案4-1024x575.jpg)
5.1 Copper Patch Panel Connection Schematic
Horizontal Cabling Subsystem (Cat6/Cat6a) → KITOZER Copper Patch Panel (K-PP-CU Series) → Network Equipment
- Work Area Outlet (K-WA Series): Connected to the rear end of the patch panel via horizontal cables (punch-down termination)
- Patch Panel Front End: RJ45 ports connected to switches/routers via jumpers
- Auxiliary Systems: Label identification system (K-LABEL Series), cable manager system (K-CM Series), grounding system (K-GND Series) for the entire link
5.2 Optical Fiber Patch Panel Connection Schematic
Backbone Optical Fiber (OM3/OM4/OS2) → KITOZER Fiber Patch Panel (K-PP-FO Series) → Network Equipment
- Outdoor Optical Cable (single-mode/multi-mode): Connected to the fiber fusion tray at the rear end of the patch panel via fusion splicing/cold splicing
- Patch Panel Front End: LC/SC/MPO adapters connected to fiber switches via pigtails
- Auxiliary Systems: Fiber protection sleeve (K-FP Series), cable management system (K-CM Series), grounding system (K-GND Series) for optical fiber links
5.3 Intelligent Patch Panel System Architecture Diagram
系统解决方案3-1024x575.jpg)
User Terminal Equipment → KITOZER Intelligent Patch Panel (K-PP-IM Series) → Management Server
- Terminal Equipment (servers/PCs/network devices): Connected to the intelligent patch panel via jumpers
- Intelligent Patch Panel: Integrates port sensors, electronic labels and control modules for real-time status monitoring and data collection
- Management Server: Deploys K-IMS management software for remote monitoring and alarm, connected to the patch panel via network
- Physical connection and network connection realize two-way data interaction between the terminal and the management server
VI. Product Technical Parameters
6.1 General Technical Parameters of Copper Patch Panels
系统解决方案2-1024x575.jpg)
| Parameter Category | Technical Index | Remarks |
|---|---|---|
| Electrical Performance | Contact resistance: ≤2.5mΩ<br>Insulation resistance: ≥1000MΩ (DC 1000V)<br>Withstand voltage: DC 1000V (AC 750V) for 1 minute without breakdown | Compliant with TIA-568-C.2 standard |
| Transmission Performance | Cat5e: 100MHz<br>Cat6: 250MHz<br>Cat6a: 500MHz<br>Cat7: 600MHz<br>Cat8: 2000MHz | Supports 10Gbps (Cat6a) ~ 40Gbps (Cat8) |
| Physical Characteristics | Plugging life: ≥1000 times<br>Punch-down life: ≥250 times<br>Operating temperature: -10℃~60℃<br>Storage temperature: -40℃~68℃ | Metal material, UL94V-0 fire rating |
| Structural Features | 19-inch standard rack mount<br>1U/2U height optional<br>Port density: 24/48/96 ports<br>Supports T568A/T568B wiring sequence | Modular design, supports hot-swappable replacement |
6.2 General Technical Parameters of Optical Fiber Patch Panels
系统解决方案1-1024x575.jpg)
| Parameter Category | Technical Index | Remarks |
|---|---|---|
| Optical Performance | Insertion loss: ≤0.3dB (single-mode), ≤0.2dB (multi-mode)<br>Return loss: ≥50dB (single-mode), ≥35dB (multi-mode) | Compliant with IEC 61754 standard |
| Physical Characteristics | Adapter type: SC/LC/MPO/ST<br>Fiber type: single-mode (OS2)/multi-mode (OM3/OM4)<br>Port density: 24/48/96/144 cores | 1U height, 19-inch standard installation |
| Environmental Adaptability | Operating temperature: -20℃~70℃<br>Relative humidity: 5%~95% (no condensation)<br>Protection grade: IP20 | Metal shell, dust and moisture proof design |
| Connection Characteristics | Plugging times: ≥1000 times<br>Optical cable bending radius: ≥10×cable diameter<br>Fusion tray capacity: 12/24 cores | Supports both fusion splicing and cold splicing termination methods |
6.3 Core Technical Parameters of Intelligent Patch Panels
| Parameter Category | Technical Index | Remarks |
|---|---|---|
| Intelligent Functions | Port connection status monitoring<br>Real-time link identification<br>Remote configuration management<br>Automatic fault alarm | Supports SNMP protocol |
| Data Transmission | Monitoring response time: ≤1 second<br>Data update frequency: 1Hz<br>Communication interface: RJ45 Ethernet<br>Power supply: PoE/DC 12V | Compatible with mainstream network management systems |
| System Compatibility | Supports Cat5e~Cat8 copper cables<br>Compatible with SC/LC/MPO optical fibers<br>Adapts to standard 19-inch cabinets | Plug and play, no additional configuration required |
| Security Features | Port access control<br>Operation log recording<br>Encrypted data transmission<br>Tamper-proof design | Compliant with information security standards |
VII. Product Application Scope
With its high flexibility and compatibility, the KITOZER computer room cabling and patch panel system is widely used in the following scenarios:
- Data centers and cloud computing centers: Supports high-density deployment, meets the ultra-large-scale data transmission needs, and adapts to virtualization and cloud computing environments
- Enterprise-level computer rooms: Provides standardized cabling management, simplifies network topology, improves operation and maintenance efficiency, and supports rapid business expansion
- Financial institutions: Shielded products meet high security requirements, and intelligent management functions ensure the stable operation of trading systems
- Government and public institutions: Complies with national information security standards, supports hierarchical management and permission control, and adapts to government cloud platforms
- Medical industry: Anti-interference design meets the electromagnetic compatibility requirements of medical equipment, and supports the stable operation of key systems such as HIS/LIS
- Educational and scientific research institutions: Modular design supports flexible laboratory layout, and high-density ports meet the needs of scientific research computing
- Industrial automation: Adapts to industrial environments, supports stable transmission under harsh conditions, and adapts to intelligent manufacturing production lines
- Telecom operators: Supports long-distance transmission and high-density interconnection, meeting the construction needs of 5G base stations and core networks
VIII. Product Advantages
8.1 Technical Advantages
- Full product series coverage: Provides a full range of patch panel products from Cat5e to Cat8 copper cables and OM3 to OS2 optical fibers to meet different rate requirements
- High-density design: Copper patch panels support up to 48 ports/1U, and optical fiber patch panels support up to 144 cores/1U, significantly improving space utilization
- Intelligent management: Integrates intelligent monitoring modules to realize real-time port status monitoring and reduce fault troubleshooting time by more than 70%
- Electromagnetic compatibility: Shielded products provide excellent anti-interference performance to meet stringent electromagnetic environment requirements
- Modular structure: Supports rapid module replacement without re-cabling, reducing maintenance costs
8.2 Performance Advantages
- Excellent transmission performance: All products pass third-party testing, and performance parameters exceed international standard requirements
- Ultra-long service life: Port plugging life ≥1000 times, punch-down life ≥250 times, with a 25-year quality guarantee
- Stability and reliability: Adopts high-quality materials and precision manufacturing processes, mean time between failures (MTBF) ≥100,000 hours
- Strong environmental adaptability: Operating temperature range of -10℃~60℃, adapting to various computer room environmental conditions
8.3 Economic Advantages
- Reduce total cost of ownership: Reduces equipment port plugging loss by 92% and extends equipment service life
- Improve operation and maintenance efficiency: Standardized management reduces manual maintenance costs and shortens fault repair time
- Investment protection: Modular design supports future technological upgrades without overall system replacement
- Green and environmental protection: Low power consumption design, compliant with RoHS environmental standards, reducing energy consumption and carbon emissions
IX. Product Bid Control Parameters
9.1 Bid Control Parameters for Copper Patch Panels (Core Technical Requirements)
- Qualification requirements: Products must pass UL, ETL or TIA certification, and provide copies of certification certificates
- Performance grade:
- Cat6: Supports 250MHz bandwidth, compliant with ANSI/TIA-568-C.2 standard, power sum near-end crosstalk (PSNEXT) ≥44dB@250MHz
- Cat6a: Supports 500MHz bandwidth, alien near-end crosstalk (ANEXT) ≥50dB@500MHz, return loss ≥10dB@500MHz
- Structural design:
- 19-inch standard rack mount, 1U height, port density ≥24 ports
- Adopts modular design, supports front/rear two termination methods for easy operation and maintenance
- Metal shell with grounding protection device, shielding effectiveness of shielded products ≥30dB@1GHz
- Material requirements:
- Contact parts: Phosphor bronze material with gold plating thickness ≥50 microinches to ensure electrical conductivity and corrosion resistance
- Insulation material: UL94V-0 flame-retardant material with fire resistance
- Termination module: Supports T568A/B two wiring sequences, tool-less design, no special tools required for installation
9.2 Bid Control Parameters for Optical Fiber Patch Panels (Core Technical Requirements)
- Performance indicators:
- Insertion loss: single-mode ≤0.3dB, multi-mode ≤0.2dB; return loss: single-mode ≥50dB, multi-mode ≥35dB
- Adapter: Adopts ceramic sleeve, plugging life ≥1000 times, repeatability ≤0.1dB
- Structural characteristics:
- Supports multiple interface types such as SC/LC/MPO, which can be mixed configured
- 1U height supports ≥24-core LC duplex ports or ≥12-core MPO ports
- Equipped with fusion tray, supports 12/24-core optical cable termination, optical cable bending radius ≥10×cable diameter
- Environmental adaptability:
- Operating temperature: -20℃~70℃, relative humidity: 5%~95% (no condensation)
- Protection grade: IP20, metal shell with good dustproof performance
- Management characteristics:
- Equipped with a complete identification system, supporting port numbering and link identification
- Optimized cable management structure to reduce fiber bending loss and facilitate maintenance operations
9.3 Bid Control Parameters for Intelligent Patch Panels (Core Technical Requirements)
- Intelligent functions:
- Supports real-time monitoring of port connection status with monitoring accuracy ≥99.9%
- Provides remote management interface, supports SNMP protocol, and can be integrated into third-party management platforms
- Has automatic link identification function, supports automatic matching of ports and jumpers, and automatic alarm for wrong connections
- Performance parameters:
- Monitoring response time ≤1 second, data update frequency ≥1Hz
- Communication interface: RJ45 Ethernet, supports PoE power supply, power consumption ≤5W per port
- Compatibility:
- Compatible with Cat5e~Cat8 copper cables and mainstream optical fiber types, no additional configuration required
- Supports standard 19-inch cabinet installation, compatible with existing cabling system upgrades
- Security features:
- Has port access permission control and operation log recording functions
- Encrypted data transmission to prevent information leakage, compliant with information security standards
X. System Solutions
10.1 Solution for Small and Medium-Sized Enterprise Computer Rooms
Solution Overview
For small and medium-sized enterprise computer rooms within 200 points, a cost-effective standardized cabling management solution is provided, adopting a combination of Cat6/Cat6a copper patch panels and LC duplex fiber patch panels, supporting 10Gbps network transmission to meet the needs of daily office and business systems.
Core Design
- Topology: Adopts star topology, with the main patch panel as the center to connect switches and servers in each area
- Copper system: Configures K-PP-CU6-24 Cat6 unshielded 24-port patch panels to support horizontal cabling termination
- Fiber system: Configures K-PP-FO-LC-24 fiber patch panels to provide backbone and uplink connections
- Management system: Configures K-CM series cable managers and K-LABEL identification system to realize standardized management
- Expansion design: Reserves 20% of ports for future business expansion
Implementation Key Points
- Cabinet layout: Adopts hot/cold aisle containment design, patch panels installed at the front of cabinets, switches at the rear
- Cable management: Horizontal cables adopt top routing, vertical cables organized by cable managers to reduce cross interference
- Grounding specification: All metal components are reliably grounded with grounding resistance ≤1Ω to ensure system electromagnetic compatibility
- Testing and acceptance: Conduct link performance testing after installation, complying with TIA-568-C.2 standard requirements
10.2 High-Density Solution for Large Data Centers
Solution Overview
For large data centers with more than 1000 points, a high-density and intelligent cabling management solution is provided, adopting Cat6a shielded patch panels and MPO fiber patch panels, supporting 40Gbps transmission rate to meet the needs of cloud computing and virtualization environments.
Core Design
- Topology: Adopts dual-link redundancy design, primary and backup patch panels are mutually redundant to improve system reliability
- Copper system: Configures K-PP-CU6A-48HD high-density 48-port Cat6a shielded patch panels, supporting 48 ports per 1U
- Fiber system: Configures K-PP-FO-MPO-12 MPO fiber patch panels, supporting 144-core fiber connection per 1U
- Intelligent management: Integrates K-PP-IM series intelligent patch panels and K-IMS management software to realize remote monitoring and fault early warning
- Expansion design: Adopts modular design, supports on-demand expansion to adapt to rapid business growth
Implementation Key Points
- High-density deployment: 48 copper ports/1U, 96 fiber cores/1U to maximize cabinet space utilization
- Intelligent management: Real-time port status monitoring through K-IMS software, automatic link report generation to reduce operation and maintenance costs
- Heat dissipation optimization: The opening rate of the front and rear of patch panels ≥70%, cooperating with the computer room air conditioning system to ensure stable equipment operation
- Redundancy design: Key links adopt dual-link redundancy with automatic fault switching to ensure business continuity
10.3 Intelligent Cabling Management Upgrade Solution
Solution Overview
For existing traditional cabling systems, an intelligent upgrade solution is provided. Without replacing the original cabling infrastructure, the intelligent management of the traditional cabling system is realized by adding intelligent management modules to improve operation and maintenance efficiency.
Core Design
- Upgrade components: Add K-IMU intelligent management modules on the basis of original patch panels to support port status monitoring
- Management software: Deploy K-IMS intelligent management software to realize real-time monitoring and alarm of port connection status
- Identification system: Replace with electronic labels to support automatic link identification and wrong connection alarm
- Data integration: Supports integration with third-party management platforms to realize unified management and data analysis
Implementation Key Points
- Lossless upgrade: No re-cabling required, add intelligent modules on existing patch panels to reduce upgrade costs
- Rapid deployment: Plug-and-play design, the upgrade process does not affect the operation of existing businesses
- Data migration: Supports the import of original link information to maintain management continuity
- Training support: Provide complete operation training to ensure that operation and maintenance personnel quickly master the use of the intelligent management system
XI. Product Application Cases
11.1 A Financial Data Center Project in Guangzhou
Project Background
The data center undertakes the bank’s core trading system and customer data storage business, with extremely high requirements for the stability, security and transmission performance of the cabling system. It needs to support more than 5000 information points and meet the 10Gbps data transmission demand.
Solution
- Adopted 40 sets of K-PP-CU6A-48HD Cat6a shielded 48-port patch panels to support high-density deployment
- Configured 15 sets of K-PP-FO-MPO-12 MPO fiber patch panels to meet the 40Gbps transmission demand of backbone links
- Integrated K-IMS intelligent management system to monitor port connection status in real time with fault early warning response time ≤1 second
- The whole system adopted a shielded design to provide more than 30dB EMI protection and ensure the security of transaction data
Implementation Effect
- The system has been operating stably for 3 years without faults, with a data transmission bit error rate of 0
- Operation and maintenance efficiency improved by 65%, fault troubleshooting time shortened from an average of 4 hours to 30 minutes
- Supports rapid business expansion, new equipment can be plug-and-play without reconfiguring the cabling system
- Obtained the Level 3 Certification of Information Security Class Protection by the People’s Bank of China, complying with financial industry standard requirements
11.2 A Cloud Data Center Project of an Internet Enterprise in Shenzhen
Project Background
The cloud data center provides cloud computing services for Internet enterprises, needs to support more than 10000 server connections, and requires the cabling system to have the characteristics of high density, low latency and easy expansion to adapt to the rapidly changing needs of virtualization and containerization environments.
Solution
- Adopted 80 sets of K-PP-CU8-24 Cat8 shielded 24-port patch panels, supporting 40Gbps transmission rate to meet the needs of high-performance computing
- Configured 30 sets of K-PP-FO-LC-48 LC duplex fiber patch panels to provide high-bandwidth interconnection links
- Adopted K-CM series high-density cable management system to optimize cable management and reduce signal interference
- Deployed K-IMS intelligent management system to realize automatic identification and configuration of port connections, supporting automatic link adjustment for virtual machine migration
Implementation Effect
- Supports high-density deployment of 48 servers per cabinet, improving space utilization by 50%
- Data transmission latency reduced to 17μs, meeting the needs of real-time computing and high-frequency trading
- Operation and maintenance costs reduced by 70%, reducing manual configuration errors and improving system reliability
- Supports elastic business expansion, the deployment time of new servers is shortened from 2 days to 4 hours, responding quickly to market demands
11.3 A HIS System Computer Room Project of a Grade III Class A Hospital in Shanghai
Project Background
The hospital’s HIS/LIS/PACS systems have extremely high requirements for the stability and anti-interference ability of the cabling system, need to support more than 2000 information points, ensure the stable operation of medical equipment and systems, and meet the security requirements of medical data transmission at the same time.
Solution
- Adopted 35 sets of K-PP-CU6-24 Cat6 unshielded 24-port patch panels to meet the network connection needs of medical equipment
- Configured 10 sets of K-PP-FO-SC-24 SC single-mode fiber patch panels to provide interconnection links between the HIS system and regional medical centers
- The whole system adopted a tamper-proof design with hierarchical port access permission control to ensure the security of medical data
- Configured K-GND series grounding system with grounding resistance ≤0.5Ω to provide good electromagnetic compatibility and avoid medical equipment interference
Implementation Effect
- The system has been operating stably for 2 years without any medical system interruption caused by cabling problems
- Supports plug-and-play of medical equipment, the access time of new equipment is shortened from 1 day to 2 hours
- Complies with the Basic Functional Specifications for Hospital Information Systems by the National Health Commission, and passes the medical industry information security certification
- Operation and maintenance costs reduced by 50%, reducing the frequency of manual patrols and realizing automatic fault alarm and positioning
XII. SEO Keywords and Tags
Search Keywords (sorted by importance)
- KITOZER computer room cabling patch panel
- KITOZER copper patch panel
- KITOZER fiber patch panel
- Intelligent patch panel system
- High-density computer room cabling solution
- Data center patch panel management system
- Shielded patch panel solution
- Cat6a/Cat8 patch panel application
- Computer room cabling system schematic diagram
- Patch panel bid control parameters
- Structured cabling system solution
- Modular patch panel design
- Computer room cabling system composition
- Patch panel technical parameters
- Computer room cabling system application cases
SEO Tags
Computer room cabling; Patch panel system; KITOZER brand; Data center cabling; Intelligent cabling management; High-density patch panel; Copper and fiber hybrid cabling; Structured cabling solution; Network cabling management; Computer room construction; Cabling system design; Electromagnetic shielded patch panel; Cabling system maintenance; Patch panel installation; Network infrastructure construction