1. System Introduction
1.1 System Overview
The KITOZER computer room grounding copper foil system is an integrated lightning and static protection grounding solution specially designed for precision electronic equipment environments such as data centers, computer rooms, and communication base stations. Adopting high-purity electrolytic copper foil as the core conductive material, it builds an efficient, stable and low-impedance grounding network through scientific grid layout and equipotential bonding technology. The system realizes rapid discharge of lightning surges and effective dissipation of static charges, fully ensuring the operational safety of IT equipment.
1.2 Design Concepts & Principles
Compliant with national standards including GB 50174-2017 Code for Design of Data Centers and GB 50343-2012 Technical Code for Lightning Protection of Building Electronic Information Systems, the system adheres to the following design principles:
- Combined Grounding: Working grounding, protective grounding, lightning protection grounding and anti-static grounding share one set of grounding devices, with grounding resistance ≤1Ω (Class A computer room) / ≤2Ω (Class B computer room).
- Equipotential Bonding: Adopt M-type or S-type equipotential bonding to ensure potential balance of all metal components in the computer room and eliminate potential differences.
- Low-Impedance Path: Copper foil grid design provides the shortest discharge path for lightning current and static charges, reducing grounding resistance and voltage drop.
- Long-term Stability: High-corrosion-resistance pure copper material ensures long-term stable operation of the grounding system with a service life of ≥30 years.

1.3 System Functional Features
- Lightning Protection: Rapidly discharges lightning surge current, limits overvoltage at equipment terminals, and protects electronic devices from lightning damage.
- Static Electricity Prevention: Continuously dissipates human body static electricity and static charges generated by equipment operation to avoid electrostatic breakdown of electronic components.
- Electromagnetic Shielding: The copper foil grid forms a Faraday cage effect, effectively shielding external electromagnetic interference and improving equipment operation stability.
- Potential Equalization: Eliminates potential differences between different equipment and prevents equipment damage caused by ground potential counterattack.
- Signal Interference Suppression: Reduces ground loop interference and ensures the quality of communication and data transmission.
2. System Composition
| System Module | Core Components | Function Description |
| Grounding Copper Foil Network | KITOZER electrolytic copper foil (multiple specifications) | Core conductor, forms grid-shaped grounding paths and undertakes main current discharge tasks |
| Equipotential Connection Terminal | Copper equipotential connector, grounding busbar | Connects copper foil and equipment grounding terminals to realize equipotential bonding |
| Grounding Lead-out Device | Copper grounding lead-out wire, grounding terminal plate | Connects the copper foil network to building grounding bodies or independent grounding electrodes |
| Fixing & Insulating Accessories | Conductive adhesive, copper foil tape, insulating fixing clips | Ensure reliable connection, firm fixation and insulation safety of copper foil |
| Anti-corrosion Protection Components | Tinned copper connectors, anti-corrosion coating, sealant | Prevents oxidation and corrosion of copper foil connections and extends service life |
| Testing & Monitoring Devices | Grounding resistance tester, equipotential test points | Used for system installation commissioning and daily maintenance detection |

3. System Classification
3.1 Classification by Copper Foil Material
| Category | Material Characteristics | Applicable Scenarios |
| Pure Copper Foil System | ≥99.99% purity electrolytic copper, conductivity ≥58MS/m, good flexibility | High-precision computer rooms, Class A data centers, scenarios with ultra-high conductivity requirements |
| Tinned Copper Foil System | Pure copper base with tin plating on surface, enhanced anti-corrosion performance | Computer rooms in humid and coastal areas, scenarios requiring long-term operational stability |
| Composite Copper Foil System | Composite structure of copper foil + insulating back adhesive + conductive adhesive, convenient construction | Renovation projects, rapid deployment scenarios, computer rooms with high installation efficiency requirements |
3.2 Classification by Grid Structure
| Category | Structural Characteristics | Applicable Scenarios |
| M-type Grid System | Copper foil crosses vertically and horizontally to form grids of 500mm×500mm ~ 2000mm×2000mm | Large-area computer rooms and open layouts, suitable for S-type equipotential bonding |
| S-type Single-point System | Radial copper foil layout centered on grounding busbar | Small computer rooms and centralized cabinet layouts, suitable for single-point grounding |
| Ring + Grid Composite System | Combination of peripheral ring copper foil and internal grid copper foil | Key computer rooms and high-security-level scenarios with dual grounding guarantee |
3.3 Classification by Application Scenario
- Data Center Dedicated Type: Designed for large-scale data centers, copper foil thickness ≥0.2mm, grid spacing ≤1m×1m, meeting Class A computer room standards.
- Communication Computer Room Type: Suitable for communication base stations and switching rooms, copper foil width ≥80mm, focusing on lightning and static protection for communication equipment.
- Industrial Control Computer Room Type: Strong anti-interference capability, combined copper foil and shielding layer, applicable to industrial automation control centers.
- Medical Equipment Computer Room Type: Low-impedance design with grounding resistance ≤0.5Ω, meeting high-precision operation requirements of medical equipment.
- Renovation & Upgrade Type: Ultra-thin copper foil (thickness ≤0.1mm), suitable for existing computer room renovation without large-scale construction.
4. System Configuration List (Brand: KITOZER)
4.1 Standard Configuration List (100㎡ Computer Room)
| No. | Product Name | Specification Model | Quantity | Unit | Remarks |
| 1 | High-purity Electrolytic Copper Foil | KT-CF-100-0.2 (100mm×0.2mm) | 400 | Meter | Purity ≥99.99%, conductivity ≥58MS/m |
| 2 | Copper Foil Conductive Adhesive | KT-CA-50 | 20 | Piece | Volume resistivity ≤0.01Ω·cm, curing time ≤24h |
| 3 | Equipotential Busbar | KT-BUS-50×5 (50mm×5mm red copper) | 4 | Meter | For equipotential connection around the computer room |
| 4 | Cabinet Grounding Terminal | KT-GT-16 | 30 | Piece | Compatible with 16mm² grounding wire, tinned copper |
| 5 | Grounding Lead-out Wire | KT-GL-35 (35mm² stranded copper wire) | 10 | Meter | Connects copper foil network and building grounding body |
| 6 | Copper Foil Fixing Clip | KT-FC-100 | 200 | Piece | Insulating material, fixed at spacing ≤500mm |
| 7 | Tinned Copper Connector | KT-CJ-100 | 50 | Piece | For copper foil cross connection with anti-corrosion treatment |
| 8 | Insulating Sealant | KT-IS-50 | 10 | Piece | Seals and moisture-proofs copper foil connections |
| 9 | Equipotential Test Point | KT-TP-01 | 8 | Piece | Convenient for system detection with nameplate |
| 10 | Construction Tool Set | KT-TK-01 | 1 | Set | Including copper foil cutting, crimping and testing tools |
4.2 Custom Configuration Options
Customized configurations are available according to computer room scale, equipment density and safety level:
- Copper Foil Specification Customization: Width 50mm~300mm, thickness 0.05mm~0.5mm to meet different current carrying requirements.
- Grid Spacing Adjustment: Standard spacing 1m×1m, customizable 0.5m×0.5m (high-density equipment area) or 2m×2m (open area).
- Special Environment Accessories: High-temperature resistant copper foil (-50℃~150℃), waterproof copper foil, flame-retardant copper foil, etc.
- Intelligent Monitoring Upgrade: Optional online grounding resistance monitoring module to monitor grounding system status in real time.

5. System Schematic Diagram
5.1 System Architecture Schematic
| Plain Text ┌─────────────────────────────────────────┐ │ Computer Room Building Grounding Body / Grounding Electrode │ └───────────────────┬─────────────────────┘ │ ┌───────────▼───────────┐ │ Grounding Lead-out Terminal Board │ └───────────┬───────────┘ │ ┌───────────▼───────────┐ │ Peripheral Main Copper Foil (300mm Width) │ └───────────┬───────────┘ │ ┌───────────────────┴───────────────────┐ │ Grid Copper Foil Network (100mm Width, 1m×1m Spacing) │ └───────────┬───────────────────┬───────┘ │ │ ┌───────▼───────┐ ┌─────▼─────┐ │ Cabinet Grounding Terminal │ │ Equipment Grounding Terminal │ └───────┬───────┘ └─────┬─────┘ │ │ ┌───────▼───────┐ ┌─────▼─────┐ │ Server / Switch │ │ Precision Instrument │ └───────────────┘ └───────────┘ |
5.2 Equipotential Bonding Schematic
| Plain Text Copper Foil Grid ────┬─── Conductive Adhesive Connection ────┬─── Equipotential Busbar ────┬─── Grounding Lead-out Wire ──── Building Grounding Body │ │ │ ├─── Cabinet Grounding ──────────────┤ │ │ │ │ ├─── Raised Floor Bracket ───────────┤ │ │ │ │ └─── Metal Cable Trunking ───────────┘ │ │ └─── Other Grounding Devices (UPS, Air Conditioner) |
5.3 Copper Foil Cross Connection Schematic
| Plain Text ┌─────────────┐ ┌─────────────┐ │ Horizontal Copper Foil │ │ Vertical Copper Foil │ │ (100mm Width) │ │ (100mm Width) │ └───────┬─────┘ └─────┬───────┘ │ │ └─────────┬─────────┘ │ ┌─────────▼─────────┐ │ Tinned Copper Connector + Conductive Adhesive │ │ (Cross Point Processing) │ └───────────────────┘ |
6. Product Technical Parameters
6.1 Core Parameters of KITOZER Grounding Copper Foil
| Parameter Item | Technical Index | Test Standard |
| Material Purity | ≥99.99% electrolytic copper | GB/T 5231-2021 |
| Thickness Specification | 0.05mm/0.1mm/0.2mm/0.3mm/0.5mm, tolerance ±0.02mm | — |
| Width Specification | 50mm/80mm/100mm/150mm/200mm/300mm, tolerance ±0.5mm | — |
| Conductivity | ≥58MS/m | GB/T 3048.2-2023 |
| Sheet Resistance | ≤0.015Ω/□ (0.2mm thickness) | ASTM D257 |
| Tensile Strength | ≥200N/mm² | GB/T 228.1-2021 |
| Elongation | ≥30% | GB/T 228.1-2021 |
| Temperature Resistance Range | -50℃~150℃, no embrittlement or cracking | — |
| Corrosion Resistance | Salt spray test ≥1000 hours | GB/T 10125-2021 |
| Insulation Performance | Back insulating layer breakdown voltage ≥10kV | GB/T 1408.1-2016 |
6.2 Supporting Component Technical Parameters
| Component Name | Key Parameters | Performance Index |
| Conductive Adhesive | Volume Resistivity | ≤0.01Ω·cm, no flowing after curing |
| Equipotential Connector | Contact Resistance | ≤0.001Ω, plugging life ≥1000 times |
| Grounding Busbar | Material / Size | Pure copper, thickness ≥5mm, width ≥50mm |
| Tinned Copper Connector | Tin Plating Thickness | ≥5μm, consistent conductivity with pure copper |
| Copper Foil Fixing Clip | Insulation Resistance / Flame Retardancy | Insulation resistance ≥10¹⁰Ω, V0 flame retardant grade |
| Grounding Lead-out Wire | Conductor Cross-sectional Area | 16mm²/25mm²/35mm², stranded copper core |

7. Product Application Scope
7.1 Core Application Scenarios
- Data Center Computer Rooms: Class A/B/C data centers, cloud computing centers, server cluster computer rooms.
- Communication Computer Rooms: Telecommunication rooms, mobile base stations, unicom rooms, radio and television transmitting rooms.
- Financial Institution Computer Rooms: Bank data centers, securities trading system rooms, insurance core business rooms.
- Government & Enterprise Computer Rooms: Government cloud rooms, enterprise private clouds, industrial control rooms.
- Medical Equipment Computer Rooms: Hospital imaging centers, precision medical equipment control rooms, laboratories.
7.2 Special Application Environments
- High Static Risk Areas: Electronic production workshops, semiconductor clean rooms, precision instrument laboratories.
- Strong Electromagnetic Interference Environments: Radar stations, satellite ground stations, power dispatching centers.
- Humid / Corrosive Environments: Coastal computer rooms, underground computer rooms, chemical enterprise computer rooms.
- Renovation & Upgrade Projects: Old computer room grounding system renovation, new equipment grounding expansion.
- Mobile Computer Rooms: Container data centers, modular computer rooms, temporary computer rooms.

8. Product Advantages
8.1 Performance Advantages
- Ultra-low Impedance: High-purity copper foil material with grounding resistance ≤0.5Ω, far exceeding national standard requirements.
- Fast Current Discharge: Large copper foil surface area enables lightning current discharge speed 3-5 times faster than traditional flat steel.
- Potential Equalization: Grid design ensures indoor potential difference ≤0.1V, effectively preventing ground potential counterattack.
- Electromagnetic Shielding: Copper foil grid forms a Faraday cage with shielding efficiency ≥60dB (10kHz~1GHz).
- Strong Weather Resistance: Stable operation in -50℃~150℃ temperature range, adapting to various extreme environments.
8.2 Construction & O&M Advantages
- Lightweight Design: Copper foil thickness only 0.2mm, lighter than traditional copper bars/flat steel, reducing building load-bearing requirements.
- Convenient Construction: Good flexibility for bending and laying, adapting to complex ground conditions, improving construction efficiency by 50%.
- Space Saving: Ultra-thin design occupies no floor height, especially suitable for low-floor-height computer rooms.
- Simple Maintenance: Welding-free connection technology facilitates later expansion and maintenance, reducing O&M costs.
- Environmental Safety: No heavy metal pollution, RoHS compliant and recyclable.
8.3 Economic Advantages
- High Cost Performance: 30% lower cost and 20% higher performance compared with copper bar solutions.
- Long Service Life: ≥30-year service life, reducing replacement frequency and maintenance costs.
- Energy Saving Effect: Low-impedance characteristic reduces power loss and saves long-term electricity costs.
- Risk Reduction: Reduces equipment damage risks and losses caused by data loss and business interruption.
9. Bid-winning Control Parameters
9.1 Core Bid Control Indicators
- Material Requirement: Grounding copper foil must adopt ≥99.99% purity electrolytic copper, complying with GB/T 5231-2021 standard.
- Size Specification: Thickness ≥0.2mm, width ≥100mm, sheet resistance ≤0.015Ω/□.
- Conductivity: ≥58MS/m, complying with IEC international standards.
- Equipotential Bonding: Copper foil cross connections must adopt tinned copper connectors + conductive adhesive treatment with contact resistance ≤0.001Ω.
- Grounding Resistance: Combined grounding system resistance ≤1Ω (Class A) / ≤2Ω (Class B), complying with GB 50174-2017.
- Service Life: ≥30 years, no corrosion after 1000-hour salt spray test.
- Construction Technology: Welding-free construction supported, copper foil fixed at spacing ≤500mm with insulation protection.
- Brand Requirement: Original KITOZER products with manufacturer authorization and quality test reports.
9.2 Technical Response Key Points
- Provide complete grounding system design scheme, including copper foil grid layout drawing, equipotential connection drawing and grounding resistance calculation document.
- Provide third-party product test reports covering key indicators such as material purity, conductivity and sheet resistance.
- Provide construction organization design scheme including construction process, quality control measures and safety guarantee plan.
- Provide after-sales service commitment including 2-year warranty, lifelong maintenance and regular inspection services.
- Provide successful cases of similar projects with user evaluation and acceptance reports.
10. Product Solution
10.1 Solution Design Process
- Demand Analysis: Clarify computer room type, equipment quantity, safety level, geological conditions and other basic information.
- On-site Investigation: Measure computer room area, ground condition, existing grounding system and soil resistivity.
- Scheme Design: Design copper foil grid layout, equipotential bonding mode and grounding lead-out scheme based on investigation results.
- Simulation Calculation: Use professional software to calculate key indicators including grounding resistance, lightning current distribution and potential difference.
- Scheme Optimization: Adjust copper foil specifications, grid spacing and connection modes according to calculation results to meet standard requirements.
- Construction Design: Formulate detailed construction drawings, material lists, construction processes and quality control standards.
10.2 Standard Construction Steps
- Ground Pre-treatment: Clean and repair the ground to ensure flat and dry surface.
- Layout & Positioning: Mark copper foil laying lines and confirm grid crossing points and connection points per design drawings.
- Copper Foil Laying: Lay copper foil along the lines to ensure flatness without folds or damage.
- Cross Connection: Connect copper foil crossing points with tinned copper connectors and conductive adhesive for reliable contact.
- Equipotential Bonding: Install equipotential busbars and connect copper foil with cabinet and equipment grounding terminals.
- Grounding Lead-out: Connect the copper foil network to building grounding bodies or independent grounding electrodes via grounding lead-out wires.
- Insulation Treatment: Insulate non-connecting parts of copper foil to prevent short circuit and electric shock risks.
- Testing & Acceptance: Test grounding resistance and equipotential bonding effect to meet design requirements.
- Marking & Recording: Mark key system parts, record test data and form acceptance reports.
10.3 Quality Control Key Points
- Material Inspection: All copper foil and accessories must have original KITOZER marks and quality certificates.
- Connection Quality: Connection contact resistance ≤0.001Ω, tested by micro-ohmmeter.
- Laying Specification: Flat copper foil without folds, fixed spacing ≤500mm with firm connections.
- Grounding Resistance: Combined grounding system resistance ≤1Ω, independent grounding system ≤4Ω.
- Equipotential Test: Potential difference between any two points in the computer room ≤0.1V to ensure equipotential effect.
- Insulation Performance: Insulation resistance between copper foil and non-grounded metal parts ≥10⁶Ω to prevent electric leakage.
10.4 Operation & Maintenance Management Solution
- Regular Detection: Conduct at least one comprehensive inspection annually to test grounding resistance and equipotential bonding effect.
- Daily Inspection: Regularly check copper foil for damage and connection points for looseness and corrosion.
- Maintenance Recording: Establish complete maintenance files to record test data, maintenance contents and replaced parts.
- Fault Handling: Timely troubleshoot abnormal grounding resistance rise and loose connections.
- Expansion Management: Expand the grounding system per original standards for new equipment to ensure system integrity.
11. Product Application Cases
11.1 Case 1: XX Bank Head Office Data Center (Class A Computer Room)
Project Overview: Building area 5000㎡, accommodating more than 2000 servers, designed grounding resistance ≤0.5Ω.
Solution: Adopt KITOZER 0.2mm×150mm pure copper foil with 0.8m×0.8m grid spacing and M-type equipotential bonding.
Implementation Effect:
- Measured grounding resistance: 0.38Ω, far better than design requirements.
- Lightning current discharge time: ≤1μs, compliant with GB 50343-2012 standard.
- Maximum indoor potential difference ≤0.08V, effectively preventing ground potential counterattack.
- 3-year stable operation without any equipment damage caused by lightning or static electricity.
11.2 Case 2: XX Telecom 5G Core Network Computer Room
Project Overview: Modular computer room with 800㎡ area in strong electromagnetic interference environment.
Solution: Adopt KITOZER 0.3mm×200mm tinned copper foil with ring + grid composite structure for integrated shielding and grounding.
Implementation Effect:
- Electromagnetic shielding efficiency ≥70dB (10kHz~1GHz), effectively reducing external interference.
- Grounding resistance 0.42Ω, meeting high requirements of communication computer rooms.
- No corrosion on copper foil surface after salt spray test with excellent durability.
- Welding-free connection design facilitates later equipment expansion and maintenance.
11.3 Case 3: XX Hospital Imaging Center Computer Room
Project Overview: Underground computer room in humid environment, precision medical equipment sensitive to static electricity and electromagnetic interference.
Solution: Adopt KITOZER 0.2mm×100mm composite copper foil (with insulating back adhesive) and M-type grid design, grounding resistance ≤0.5Ω.
Implementation Effect:
- Static voltage ≤50V during human-equipment contact, zero equipment damage cases caused by static electricity.
- Effectively shields electromagnetic interference from MRI, CT and other equipment to ensure normal operation of other devices.
- Waterproof composite copper foil design prevents moisture damage during long-term operation.
- Zero safety accidents after 2-year stable system operation.
12. SEO Keywords & Tags
12.1 Search Keywords
Computer room grounding copper foil, KITOZER grounding copper foil, computer room lightning protection grounding, data center grounding system, equipotential bonding, anti-static grounding, lightning protection grounding solution, copper foil grounding grid, computer room grounding renovation, Class A computer room grounding standard
12.2 SEO Optimization Tags
- Main Tags: Computer Room Grounding Copper Foil, KITOZER, Lightning Protection Grounding, Data Center
- Secondary Tags: Equipotential Bonding, Static Prevention, Grounding System, Copper Foil Grounding Grid, Computer Room Renovation
- Technical Tags: GB 50174-2017, GB 50343-2012, Grounding Resistance, Lightning Current Discharge
- Application Tags: Data Center Room, Communication Room, Financial Room, Medical Room, Modular Room
- Advantage Tags: Low Impedance, Fast Discharge, Potential Equalization, Electromagnetic Shielding, Convenient Construction