KITOZER
KITOZER

KITOZER Computer Room Lighting Distribution Cabinet (Distribution Box) Solution

I. System Introduction

1.1 Core Definition

The KITOZER computer room lighting distribution cabinet (distribution box) is a professional lighting power distribution system specially designed for precision electronic equipment environments such as data centers, computer rooms and server rooms. As an essential part of the computer room power supply and distribution system, it undertakes centralized control, protection and management of the computer room lighting system, ensuring the reliability, safety, stability and intelligent control of lighting power supply.

1.2 Design Standards

The system strictly complies with the following national standards and specifications:

  • GB 50174-2017 Code for Design of Data Centers
  • GB 50034-2013 Standard for Lighting Design of Buildings
  • GB 7251.1-2013 Low-voltage Switchgear and Controlgear Assemblies – Part 1: General Rules
  • GB 51348-2019 Standard for Electrical Design of Civil Buildings
  • Data center illumination standards: Main computer room: 300lx~500lx; Auxiliary area: ≥300lx; Standby lighting: ≥10% of general lighting illuminance

1.3 Core Values

  • Power Supply Reliability: Dual-circuit power supply design ensures continuous and stable computer room lighting, enabling seamless switching between auxiliary area and main computer room standby lighting.
  • Safety Protection: Multiple electrical protection mechanisms prevent electrical faults such as short circuit, overload and electric leakage to protect personnel and equipment safety.
  • Intelligent Management: Supports remote monitoring, timing control and scene control to improve operation and maintenance efficiency and reduce energy consumption.
  • Precise Power Distribution: Modular design adapts to lighting demands of computer rooms of different scales, facilitating expansion and maintenance.
kitozer data center lighting distribution cabinet solution (8)

II. System Composition

The KITOZER computer room lighting distribution cabinet system consists of the following core components to form a complete lighting power distribution solution:

ModuleCore ComponentsFunction Description
Cabinet StructureCold-rolled steel enclosure, protective panel, mounting bracketProvides mechanical protection and installation foundation; protection grade optional from IP30 to IP54
Main Power Distribution UnitMain circuit breaker, disconnector, Automatic Transfer Switch (ATS)Realizes main power control and automatic switching between main and standby power sources to guarantee power supply continuity
Branch Protection UnitMiniature Circuit Breaker (MCB), Residual Current Circuit Breaker (RCCB/RCBO)Provides branch overload, short circuit and leakage protection; single-circuit current ≤16A, maximum 25 lamps per circuit
Measurement & Monitoring UnitMulti-functional power meter, current transformer, temperature and humidity sensorReal-time monitoring of voltage, current, power, electric energy, temperature and other parameters
Intelligent Control UnitIntelligent lighting controller, communication module, HMISupports remote control, timing control and scene mode switching; compatible with Modbus/DNP3 communication protocols
Surge Protection UnitSurge Protective Device (SPD), lightning protection moduleProtects against induced lightning and power overvoltage to safeguard lighting equipment
Auxiliary ComponentsBusbar, terminal block, identification system, ventilation and heat dissipation deviceGuarantees reliable electrical connection and facilitates maintenance and management
kitozer data center lighting distribution cabinet solution (7)

III. System Classification

3.1 Classification by Installation Mode

TypeFeaturesApplication Scenarios
Wall-mountedCompact size, flexible installation, small space occupationLighting power distribution for small and medium-sized computer rooms and auxiliary areas; installed on walls or equipment rooms
Floor-standingLarge capacity, strong expandability, suitable for multi-circuit complex systemsLarge-scale data centers and main computer rooms requiring centralized control of multi-region lighting
RecessedConcealed installation, neat and aesthetic appearance, excellent protection performanceHigh-end computer rooms and highly intelligent sites with integrated decoration design

3.2 Classification by Control Mode

TypeCore FeaturesTechnical Advantages
Conventional TypeManual control with basic protection functionsLow cost and simple operation, applicable to small computer rooms
Intelligent TypeRemote monitoring + local control, supports scene modesReduces energy consumption by 30%–40%, improves O&M efficiency by 50%, and enables accurate fault location
Emergency TypeIntegrated EPS emergency power supply with automatic standby lighting switchingComplies with GB 50174-2017 standby lighting requirements to meet computer room emergency lighting demands

3.3 Classification by Capacity Scale

Capacity GradeCircuit QuantityRated CurrentApplication Scenarios
Small8~20 circuitsTotal current ≤63AComputer room area <100㎡, lighting power <15kW
Medium24~40 circuitsTotal current ≤125AComputer room area 100~500㎡, lighting power 15~50kW
Large45~60 circuitsTotal current ≤250AComputer room area >500㎡, multi-level lighting system, power >50kW
kitozer data center lighting distribution cabinet solution (6)

IV. System Configuration List (Brand: KITOZER)

4.1 Configuration List of Small Computer Room Lighting Distribution Cabinet (8-circuit Wall-mounted)

No.Product NameModel & SpecificationBrandQuantityRemarks
1Lighting Distribution Box EnclosureKITOZER-KMZ-8KITOZER1 SetSize: 400×300×150mm, cold-rolled steel plate, IP30 protection grade
2Main Circuit BreakerKITOZER-KMB63-3P C63KITOZER1 Pc3-pole, rated current 63A, C-type tripping curve
3Branch Miniature Circuit BreakerKITOZER-KMB16-1P+N C16KITOZER8 Pcs1P+N, rated current 16A, maximum 25 lamps per circuit
4Residual Current Circuit BreakerKITOZER-KMR-63 30mAKITOZER1 PcGeneral leakage protection, operating current 30mA, fast fault cutoff
5Multi-functional Power MeterKITOZER-KMP-2000KITOZER1 PcMonitors voltage, current, power and electric energy, supports RS485 communication
6Surge Protective DeviceKITOZER-KMS-20 2P 20kAKITOZER1 PcProtects power side surge, response time ≤25ns
7Busbar & Terminal BlockKITOZER-KMT SeriesKITOZER1 SetCopper busbar meeting current-carrying requirements with clear identification
8Installation AccessoriesKITOZER-KMF SeriesKITOZER1 SetFixing brackets, terminal blocks, nameplates and other accessories

4.2 Configuration List of Medium Computer Room Lighting Distribution Cabinet (24-circuit Floor-standing)

No.Product NameModel & SpecificationBrandQuantityRemarks
1Lighting Distribution Cabinet EnclosureKITOZER-KMZ-24KITOZER1 SetSize: 800×600×1000mm, cold-rolled steel plate, IP40 protection grade
2Automatic Transfer Switch (ATS)KITOZER-KMA-125 3PKITOZER1 PcRated current 125A, automatic switching time ≤0.5s
3Main Circuit BreakerKITOZER-KMB125-3P C125KITOZER2 Pcs1 for main power, 1 for standby power, 3-pole, rated current 125A
4Branch Miniature Circuit BreakerKITOZER-KMB16-1P+N C10/C16KITOZER24 Pcs12×C10A (general lighting), 12×C16A (emergency lighting)
5Intelligent Lighting ControllerKITOZER-KMC-8000KITOZER1 Pc8-channel control output, supports timing and scene control, Modbus protocol
6Residual Current Circuit BreakerKITOZER-KMR-100 3P+N 30mAKITOZER2 Pcs1 for main circuit, 1 for standby circuit, leakage protection, operating time ≤0.1s
7Multi-functional Power MeterKITOZER-KMP-3000KITOZER1 PcThree-phase monitoring, harmonic analysis, power quality evaluation, LCD display
8Surge Protection SystemKITOZER-KMS-40 3P+N 40kAKITOZER1 SetThree-level surge protection for full-range lighting system protection
9Temperature & Humidity SensorKITOZER-KMT-100KITOZER2 PcsMonitors internal cabinet temperature with over-temperature alarm to ensure equipment safety
10Ventilation & Heat Dissipation DeviceKITOZER-KMV-200KITOZER2 PcsAutomatic temperature-controlled fans to maintain optimal internal cabinet temperature
11Busbar SystemKITOZER-KMB SeriesKITOZER1 SetSegmented busbar for easy expansion, copper material with insulation treatment
12Installation & Identification AccessoriesKITOZER-KMF SeriesKITOZER1 SetComplete installation accessories with clear zoning identification for easy maintenance
kitozer data center lighting distribution cabinet solution (5)

V. System Schematic Diagram

Topology Diagram of KITOZER Computer Room Lighting Distribution System

Utility Power 1 ────────┐                ┌─────── Main Lighting Circuit 1 (MCB C16) ─────── General Lighting Lamps
                   │                │
 ├─ ATS Automatic Transfer Switch ────┐
                   │                │       ├─────── Main Lighting Circuit 2 (MCB C16) ─────── General Lighting Lamps
Utility Power 2 ────────┘                │       │
                                    │       └─────── … (max. 24 circuits) ───────── …
                                    │
                                    ├─ Standby Lighting Circuit (MCB C16) ─────── Standby Lighting Lamps (≥10% illuminance)
                                    │
                                    ├─ Intelligent Control Unit ──────┐
                                    │                    │
                                    └─ Measurement & Protection Unit      ├─ Remote Monitoring System
 │
 └─ Scene Control Terminal

Core Control Logic Description

  1. Dual-power Automatic Switching: When the main power fails, the ATS automatically switches to standby power within 0.5 seconds to ensure uninterrupted lighting.
  2. Graded Protection Mechanism: Main circuit breaker → branch MCB → leakage protection, realizing accurate fault isolation and minimizing impact scope.
  3. Intelligent Control Process:
            
  4. Timing Control: Automatically turns on/off lighting according to computer room schedule and reduces illuminance during unmanned periods.
  5. Scene Control: Presets multiple lighting scenes including “Normal Operation”, “Inspection & Maintenance” and “Emergency Mode”.
  6. Linkage Control: Links with the computer room fire protection system to automatically switch to emergency lighting mode in case of fire.
  7. Remote Monitoring: Real-time viewing of each circuit status via the monitoring platform, supporting remote control and fault alarm.
kitozer data center lighting distribution cabinet solution (4)

VI. Product Technical Parameters

General Technical Parameters of KITOZER Computer Room Lighting Distribution Cabinet

Parameter CategoryTechnical IndexDescription
Basic ParametersRated VoltageAC 380V/220V, 50Hz, three-phase four-wire system
Rated Current8-circuit: 63A; 24-circuit: 125A; 48-circuit: 250A
Protection GradeOptional: IP30 (basic), IP40 (enhanced), IP54 (outdoor)
Cabinet MaterialHigh-quality cold-rolled steel plate, 1.5~2.0mm thickness, electrostatic spray surface treatment
Protection PerformanceShort-circuit Breaking Capacity≥15kA, meeting computer room power distribution safety requirements
Overload ProtectionCompliant with IEC 60898 standard, C-type curve (5In~10In)
Leakage ProtectionOperating current 30mA, operating time ≤0.1s, ensuring personal safety
Surge ProtectionClass II protection grade, maximum discharge current 20~40kA
Intelligent FunctionsCommunication InterfaceRS485, supports Modbus-RTU protocol, expandable Ethernet interface
Control ModeLocal manual + remote automatic, supports timing, scene and linkage control
Monitoring AccuracyVoltage: ±0.5%, Current: ±0.5%, Power: ±1.0%
Environmental AdaptabilityOperating Temperature-10℃~+40℃, adaptable to computer room environment
Relative Humidity≤90% (+20℃), non-condensing
Altitude≤2000m, derating required for higher altitude
Pollution DegreeGrade 3, adaptable to computer room industrial environment
Certification & QualificationProduct CertificationCCC compulsory certification, compliant with GB 7251.1-2013 standard
Environmental CertificationRoHS compliant, meeting EU environmental requirements
Quality StandardISO 9001 quality management system certification with strict quality control

Special Technical Parameters of KITOZER Branch Protection Switch

ModelPole NumberRated CurrentTripping CurveLeakage ProtectionApplication Scenarios
KMB16-1P+N1P+N6A/10A/16AC-typeOptionalGeneral lighting circuits, ≤25 lamps per circuit
KMB32-2P2P20A/25A/32AC-typeOptionalLarge combined lighting circuits, ≤60 lamps per circuit
KMR-633P+N32A/40A/63AC-type30mAGeneral leakage protection for overall system safety

VII. Product Application Scope

KITOZER computer room lighting distribution cabinets are applicable to the following scenarios, meeting lighting power distribution demands of computer rooms of different scales and types:

7.1 Data Center Scenarios

  • Large Cloud Data Centers: Multi-area hierarchical lighting control, automatic main/standby power switching, supporting remote monitoring and energy consumption management
  • Enterprise-level Data Centers: Modular design adapting to phased computer room construction for easy expansion and maintenance
  • Edge Computing Data Centers: Compact design adapting to space constraints of small computer rooms and ensuring lighting reliability

7.2 Computer Room Type Adaptation

Computer Room TypeRecommended ConfigurationCore Requirements
Main Computer Room24-circuit floor-standing intelligent typeHigh reliability, standby lighting ≥10% of general lighting, intelligent control
Auxiliary Area8-circuit wall-mounted conventional typeBasic lighting, meeting 300lx illuminance with cost optimization
Monitoring Center16-circuit recessed intelligent typeHigh color rendering index (≥80), glare-free, scene-based control
Battery Room / Distribution Room12-circuit protected typeExplosion-proof lighting, IP54 protection, linkage with fire protection system

7.3 Special Application Scenarios

  • Medical Computer Rooms: Isolated from medical equipment power supply system with low electromagnetic interference to ensure normal operation of medical devices
  • Financial Computer Rooms: Compliant with financial industry specifications, dual-circuit + emergency power supply to guarantee business continuity
  • Military Computer Rooms: Electromagnetic shielding design with strong anti-interference capability to meet military-grade safety requirements
  • Rail Transit Computer Rooms: Vibration-resistant design, IP40+ protection grade, supporting remote centralized management

VIII. Product Advantages

Compared with traditional lighting distribution boxes, KITOZER computer room lighting distribution cabinets have the following core advantages:

8.1 Safety & Reliability Advantages

  1. Multiple Electrical Protection: Full-range protection against short circuit, overload, electric leakage and surge with fault response time ≤0.1s to protect personnel and equipment safety.
  2. Dual-power Redundant Design: ATS automatic switching enables seamless connection between main and standby power to avoid lighting interruption affecting computer room O&M.
  3. Fire & Flame Retardant: Cabinet material reaches V0 flame retardant grade, and all internal components pass fire protection certification to reduce fire risks.
  4. Reliable Grounding: Dedicated grounding bar design with grounding resistance ≤4Ω to effectively prevent electric shock accidents.

8.2 Intelligent Management Advantages

  1. Remote Monitoring Capability: Real-time monitoring of each circuit status and energy consumption data, supporting remote control and fault alarm to improve O&M efficiency by over 50%.
  2. Scene-based Control: Presets multiple lighting modes adapting to different working scenarios, reducing energy consumption by 30%–40%.
  3. Data Visualization: Intuitively displays operational data of each circuit via the monitoring platform, supporting energy consumption analysis and optimization suggestions.
  4. System Linkage: Links with computer room Environmental Monitoring System (EMS) and fire protection system to realize intelligent management.

8.3 Structural Design Advantages

  1. Modular Design: Standard module combination facilitates expansion and maintenance, shortening computer room construction cycle.
  2. User-friendly Operation: Transparent protective door, convenient operation and clear identification reduce misoperation risks.
  3. Optimized Heat Dissipation: Reasonable air duct design ensures high heat dissipation efficiency and long-term stable operation of components.
  4. Space Adaptability: Multiple installation methods including wall-mounted, floor-standing and recessed adapt to various computer room spatial layouts.

8.4 Full Lifecycle Advantages

  1. High-quality Components: Core components service life ≥10 years, Mean Time Between Failures (MTBF) ≥50,000 hours.
  2. Maintenance-free Design: Reduces maintenance workload and O&M costs, lowering full lifecycle cost by 22%–28%.
  3. Upgradability: Reserved expansion interfaces support subsequent intelligent upgrading and protect upfront investment.
  4. Energy-saving & Eco-friendly: Compliant with RoHS standards, reduces energy consumption and supports green data center construction.

IX. Bid Control Parameters

The following core bid control parameters of KITOZER computer room lighting distribution cabinets are formulated for project bidding and technical specification compilation:

9.1 Basic Parameter Requirements

  1. Rated voltage: AC 380V/220V, three-phase four-wire system, 50Hz, voltage fluctuation range ±10%.
  2. Rated current: Total current ≥125A (medium type), branch current ≤16A, compliant with GB 51348-2019 standard.
  3. Protection grade: ≥IP30, floor-standing type ≥IP40, special area type ≥IP54.
  4. Cabinet material: Cold-rolled steel plate thickness ≥1.5mm, electrostatic spray surface, color RAL7035 (industrial gray).

9.2 Core Function Requirements

  1. Dual-power Switching: Equipped with ATS automatic transfer switch, switching time ≤0.5s, compliant with GB/T 14048.11 standard.
  2. Protection Functions:
            
  3. Short-circuit protection: Breaking capacity ≥15kA, compliant with IEC 60947-2 standard
  4. Leakage protection: Operating current ≤30mA, operating time ≤0.1s, compliant with GB 16917 standard
  5. Surge protection: Class II grade, maximum discharge current ≥20kA, response time ≤25ns
  6. Intelligent Control:
            
  7. Supports remote monitoring, RS485 communication interface, Modbus-RTU protocol
  8. Equipped with timing and scene control functions, compatible with third-party system linkage
  9. Monitoring accuracy: Voltage ±0.5%, Current ±0.5%, Power ±1.0%

9.3 Certification & Quality Requirements

  1. Product Certification: Must possess valid CCC compulsory certification certificate, compliant with GB 7251.1-2013 standard.
  2. Environmental Requirements: Compliant with RoHS directive with environmental test report provided.
  3. Quality System: Manufacturer holds ISO 9001 quality management system certification with certificate provided.
  4. Warranty Period: Overall warranty ≥2 years, core components (circuit breaker, controller) warranty ≥5 years.

9.4 Special Technical Requirements

  1. Standby Lighting: Independent standby lighting circuits with illuminance ≥10% of general lighting, compliant with GB 50174-2017 standard.
  2. Emergency Switching: Links with fire protection system to automatically switch to emergency lighting mode within 0.3s during fire incidents.
  3. Electromagnetic Compatibility: Compliant with GB/T 18802.1 standard, electromagnetic interference ≤40dBμV, anti-interference capability ≥10V/m.
  4. Identification System: Equipped with clear circuit identification, operation instructions and warning marks, compliant with GB 7251.1 standard.

X. System Solutions

10.1 Lighting Power Distribution Solution for Large-scale Data Center

Project Requirements

  • Computer room area: 800㎡, divided into main computer room, auxiliary area and monitoring center
  • Illuminance requirements: Main computer room 500lx, auxiliary area 300lx, monitoring center 400lx, standby lighting ≥10% of general lighting
  • Power supply requirements: Dual-circuit power supply with automatic standby power switching to ensure 7×24-hour lighting continuity
  • Management requirements: Remote monitoring, energy consumption statistics and scene control to reduce O&M costs

Solution Design

  1. System Architecture: Adopts 3 sets of KITOZER-KMZ-24 floor-standing intelligent lighting distribution cabinets for zonal control.
  2. Power Supply Scheme:
           
  3. Main power: 380V three-phase four-wire utility power
  4. Standby power: UPS power supply for standby and key area lighting
  5. ATS automatic transfer switch with switching time ≤0.5s
  6. Circuit Configuration:
            
  7. Main computer room: 16 circuits with C16A MCB, maximum 25 LED lamps per circuit
  8. Auxiliary area: 8 circuits with C10A MCB to meet basic lighting demands
  9. Monitoring center: 6 circuits with C16A MCB, equipped with high color rendering index (≥85) lamps
  10. Standby lighting: 4 independent circuits physically isolated from main lighting circuits for high reliability
  11. Intelligent Control:
            
  12. Equipped with KITOZER-KMC-8000 intelligent lighting controller supporting Modbus protocol
  13. Presets three scene modes: Normal Operation, Night Inspection and Emergency Mode
  14. Connects with computer room EMS to realize data sharing and linkage control
  15. Protection Mechanism:
            
  16. Dual protection of general and branch leakage protection with 30mA operating current
  17. Three-level Class II surge protection with maximum discharge current 40kA
  18. Temperature and humidity monitoring with over-temperature alarm to ensure equipment safety

Implementation Effects

  • Power Supply Reliability: Achieves 99.999% reliability with zero lighting interruption incidents, guaranteeing 7×24-hour computer room operation
  • Energy Saving: Intelligent control reduces lighting energy consumption by 35%, saving approximately RMB 80,000 in electricity costs annually
  • O&M Efficiency: Remote monitoring reduces manual inspection workload by 60% and shortens fault location time by 80%
  • Safety Guarantee: Multiple protection mechanisms eliminate electrical safety hazards and protect personnel and equipment safety

10.2 Lighting Power Distribution Solution for Small & Medium-sized Enterprise Computer Rooms

Project Requirements

  • Computer room area: 150㎡, single-area design
  • Illuminance requirements: 300lx, standby lighting ≥10% of general lighting
  • Limited budget requiring high cost performance and simple maintenance
  • Basic remote monitoring capability required

Solution Design

  1. System Architecture: Adopts 1 set of KITOZER-KMZ-16 wall-mounted intelligent lighting distribution cabinet.
  2. Power Supply Scheme:
            
  3. Main power: 220V single-phase three-wire utility power
  4. Standby power: EPS emergency power supply for standby lighting
  5. Manual/automatic transfer switch balances cost and reliability
  6. Circuit Configuration:
            
  7. Main lighting: 12 circuits with C16A MCB, maximum 25 LED lamps per circuit
  8. Standby lighting: 4 independent control circuits with illuminance ≥30lx
  9. Intelligent Control:
            
  10. Simplified intelligent controller supports timing control and remote status monitoring
  11. Mobile APP remote viewing with basic fault alarm function
  12. Protection Mechanism:
            
  13. General leakage protection + branch overload protection to meet basic safety requirements
  14. Two-level Class II surge protection with maximum discharge current 20kA

Implementation Effects

  • Cost Optimization: Reduces cost by 20% compared with traditional solutions while improving reliability
  • Easy Maintenance: Modular design shortens fault troubleshooting time by 50%
  • Enhanced Safety: Leakage and surge protection eliminate common electrical safety hazards
  • Upgraded Management: Remote monitoring reduces manual inspection frequency and improves management efficiency

XI. Product Application Cases

Case 1: Cloud Computing Data Center Project

Project Overview

  • Project Scale: Total construction area 20,000㎡, 10 independent computer room modules
  • Implementation Time: March 2025
  • Solution: 20 sets of KITOZER-KMZ-24 floor-standing intelligent lighting distribution cabinets for zonal control
  • Core Requirements: High reliability, intelligent management, energy consumption optimization

Implementation Highlights

  1. Dual-bus Power Supply: Fully isolated main and standby power with ATS automatic switching ensures zero lighting interruption.
  2. Intelligent Linkage: Deeply integrated with Data Center Infrastructure Management (DCIM) platform to realize linkage of lighting, air conditioning and security systems.
  3. Energy Consumption Management: Intelligent control reduces lighting energy consumption by 38%, saving approximately RMB 500,000 in annual electricity costs.
  4. Fault Early Warning: Real-time current and temperature monitoring predicts potential faults in advance, cutting maintenance costs by 60%.

Customer Evaluation

“The KITOZER computer room lighting distribution system features high stability and powerful intelligent management functions. It not only meets our data center lighting demands, but also realizes energy consumption optimization and management upgrading, making it the preferred product for data center construction.” — O&M Director of Cloud Computing Company Data Center

Case 2: Financial Institution Disaster Recovery Center Project

Project Overview

  • Project Scale: 500㎡ computer room constructed per Class A computer room standards
  • Implementation Time: August 2025
  • Solution: 8 sets of KITOZER-KMZ-16 recessed intelligent lighting distribution cabinets
  • Core Requirements: High safety, emergency guarantee, electromagnetic compatibility

Implementation Highlights

  1. Electromagnetic Shielding Design: The cabinet adopts electromagnetic shielding materials to reduce interference of the lighting system on financial equipment.
  2. Emergency Lighting: Standby lighting is completely independent of main lighting with illuminance ≥50%, meeting financial industry specifications.
  3. Fire Protection Linkage: Links with fire alarm system to automatically switch to emergency lighting mode during fires to ensure personnel evacuation.
  4. Remote Management: Supports 7×24-hour remote monitoring and real-time fault alarm push to guarantee safe operation of the disaster recovery center.

Customer Evaluation

“The KITOZER lighting distribution system fully meets the high safety requirements of our disaster recovery center. Especially the emergency lighting and fire linkage functions provide strong support for our business continuity.” — Person-in-charge of Bank Disaster Recovery Center

Case 3: University Data Center Computer Room Renovation Project

Project Overview

  • Project Scale: 200㎡ existing computer room renovation
  • Implementation Time: January 2026
  • Solution: 4 sets of KITOZER-KMZ-8 wall-mounted conventional lighting distribution cabinets
  • Core Requirements: Cost control, rapid deployment, reliability improvement

Implementation Highlights

  1. Rapid Installation: Wall-mounted design requires no computer room renovation, cutting installation time by 70%.
  2. Cost Optimization: Renovation cost reduced by 40% compared with new construction while improving lighting quality.
  3. Illuminance Upgrade: Post-renovation illuminance increased from 200lx to 400lx, complying with GB 50174-2017 standards.
  4. Protection Upgrade: Added leakage and surge protection to improve computer room power utilization safety.

Customer Evaluation

“The KITOZER lighting distribution system provides a cost-effective solution for our old computer room renovation. It not only improves lighting quality and safety, but also helps control the renovation budget. We are highly satisfied.” — Director of University Information Center

XII. Search Keywords, SEO & Tags

Core Search Keywords

Computer room lighting distribution cabinet, computer room lighting distribution box, KITOZER lighting distribution cabinet, data center lighting power distribution, computer room emergency lighting system, intelligent lighting distribution box, computer room lighting solution, computer room lighting bid parameters, GB50174 computer room lighting standard, dual-power lighting distribution box

SEO Optimization Keywords

Primary Keywords

Computer room lighting distribution cabinet, data center lighting distribution box

Long-tail Keywords

  • KITOZER intelligent lighting distribution cabinet solution
  • Computer room dual-power lighting distribution box system design
  • Data center standby lighting power distribution standard
  • Computer room lighting distribution cabinet bid parameter requirements
  • Application of intelligent lighting distribution box in computer rooms

Product Tags

#ComputerRoomLightingDistributionCabinet #DataCenterLighting #KITOZER #IntelligentLighting #DualPowerSwitching #EmergencyLighting #ComputerRoomDistributionSystem #LightingBidParameters #GB50174 #EnergySavingLighting