KITOZER Computer Room Power Distribution Cabinet Solution

1. System Introduction

1.1 System Overview

The KITOZER Computer Room Power Distribution Cabinet (Power Distribution Box) is an intelligent low-voltage power distribution solution specially designed for data centers, computer rooms and server rooms. As the core hub of the computer room power supply system, it centrally manages, distributes, protects and monitors multi-channel input power sources including mains electricity, UPS power and generators, delivering stable, reliable and safe power supply for servers, storage devices, network equipment, precision air conditioners, lighting systems and other terminal loads.

Complying strictly with national standards including GB50174-2017 Code for Design of Data Centers and GB7251 Low-voltage Switchgear and Controlgear Assemblies, the system features high reliability, intelligence and scalability. It supports Tier II to Tier IV data center power distribution architectures and meets the stringent requirements of modern computer rooms for power continuity, power quality and operation & maintenance management.

1.2 Core Functions

  • Power Distribution: Distribute input electric energy to various electrical equipment on demand, supporting multi-channel power input and flexible output configuration.
  • Power Protection: Adopt multi-level protection mechanisms against overload, short circuit, overvoltage, undervoltage, electric leakage and surge to ensure equipment safety.
  • Intelligent Monitoring: Real-time monitoring of voltage, current, power, electric energy and other parameters, supporting remote communication and centralized management.
  • Fault Isolation: Quickly cut off faulty circuits during faults to avoid affecting the normal operation of other equipment.
  • Redundancy Design: Support N+1 redundant configuration and hot-swappable core components to improve system availability.
  • Power Energy Management: Accurately measure energy consumption of each circuit to support energy efficiency analysis and optimization.
data center power cabinet solution (6)

2. System Composition

The KITOZER computer room power distribution cabinet consists of the following core components to form a complete power supply and distribution solution:

ComponentCore PartsFunction Description
Cabinet StructureStandard cabinet, sealed panel, heat dissipation system, door lock deviceProtection rating IP20~IP40, providing mechanical protection and electromagnetic shielding to ensure safe and stable equipment operation
Main Circuit SystemAir Circuit Breaker (ACB), Molded Case Circuit Breaker (MCCB), Miniature Circuit Breaker (MCB)Realize main power control and protection with breaking capacity ranging from 50kA to 100kA, meeting the short-circuit current requirements of computer rooms
Control Circuit SystemContactor, relay, control switch, indicator light, operation buttonRealize remote control, status indication and fault alarm of power circuits
Measurement & Monitoring UnitSmart electric meter, current transformer, voltage transformer, power monitoring moduleReal-time collection of electrical parameters with accuracy up to class 0.5, supporting RS485/Modbus communication
Protection DevicesSurge Protective Device (SPD), lightning protection module, Earth Leakage Circuit Breaker (ELCB)Class I test protection level with nominal discharge current ≥20kA, protecting equipment from lightning strikes and surge damage
Transfer DeviceATS automatic transfer switch, manual/automatic transfer switchSupport fast switching of dual power sources with switching time ≤10ms to ensure uninterrupted power supply for critical loads
Busbar SystemCopper bar, insulating support, busbar clampCarry high current, reduce power loss and support flexible system expansion
Communication InterfaceEthernet port, RS485 port, USB portRealize data interaction with DCIM systems and monitoring platforms to support remote management
Auxiliary EquipmentBackup power supply, fan, heater, lighting deviceEnsure stable operation of the power distribution cabinet under various environmental conditions

3. System Classification

Classified by computer room application scenarios and functional requirements, KITOZER computer room power distribution cabinets are divided into the following categories:

3.1 Classification by Installation Method

3.1.1 Floor-standing Power Distribution Cabinet

  • Dimensions: 600/800/1000×800×2200 (W×D×H) mm, compatible with standard computer room layout
  • Features: Large capacity and strong scalability, suitable for medium and large computer rooms and high-power loads
  • Applications: Computer room main incoming cabinet, UPS output cabinet, row head main cabinet

3.1.2 Wall-mounted Power Distribution Box

  • Dimensions: 400×300×200 ~ 800×600×400 (W×D×H) mm, compact and miniaturized
  • Features: Flexible installation and space-saving, ideal for small computer rooms and branch circuits
  • Applications: Auxiliary power box, lighting distribution box, local equipment power supply box

3.1.3 Rack-mounted Power Distribution Cabinet

  • Dimensions: Standard 19-inch rack installation, height optional from 1U to 12U
  • Features: Compatible with cabinet layout, convenient for centralized management and support hot swapping
  • Applications: Server cabinet row head cabinet, network equipment distribution cabinet

3.2 Classification by Functional Purpose

3.2.1 Incoming Power Distribution Cabinet

  • Core Functions: Main power access, energy metering, main protection, ATS switching
  • Configuration: Air circuit breaker (ACB), ATS automatic transfer switch, smart electric meter, surge protective device
  • Applications: Main incoming power management for computer room mains/generator/UPS systems

3.2.2 UPS Output Cabinet

  • Core Functions: UPS power distribution, overload protection, precision metering
  • Configuration: Molded case circuit breaker, intelligent monitoring module, electric energy meter
  • Applications: Provide uninterrupted power supply for critical loads such as servers and storage devices

3.2.3 Row Head Cabinet

  • Core Functions: Power distribution for cabinet rows, branch circuit protection, energy consumption monitoring
  • Configuration: Multiple miniature circuit breakers, intelligent PDU interface, monitoring module
  • Applications: Terminal power management for data center cabinet rows, supporting independent metering per cabinet

3.2.4 Auxiliary Power Distribution Cabinet

  • Core Functions: Power supply for air conditioning, lighting, fresh air and other auxiliary equipment
  • Configuration: Molded case circuit breaker, contactor, thermal relay
  • Applications: Power management for computer room environmental equipment

3.2.5 Emergency Power Distribution Cabinet

  • Core Functions: Power supply for critical emergency loads such as emergency lighting and fire-fighting equipment
  • Configuration: Dual power transfer device, emergency power module
  • Applications: Guarantee basic operation of computer rooms under emergency conditions

3.3 Classification by Redundancy Level

3.3.1 Single-power Power Distribution Cabinet (N Configuration)

  • Features: Single-channel power input, suitable for non-critical loads
  • Applications: Power supply for auxiliary equipment such as ordinary lighting and non-critical ventilation equipment

3.3.2 Dual-power Power Distribution Cabinet (N+1 Configuration)

  • Features: Dual-channel power input with automatic ATS switching, meeting Tier III data center standards
  • Applications: Power supply for critical loads such as servers and network equipment

3.3.3 Redundant Power Distribution Cabinet (2N Configuration)

  • Features: Two completely independent parallel operating systems, meeting Tier IV data center standards
  • Applications: Core business systems in finance, telecommunications and other zero-interruption critical computer rooms
data center power cabinet solution (5)

4. System Configuration List (Brand: KITOZER)

The following is the standard configuration list of KITOZER computer room power distribution cabinets, which can be customized according to actual demands:

4.1 Configuration List of Floor-standing Main Incoming Power Distribution Cabinet (Model: KZ-PD-800)

No.Component NameSpecification & ModelBrandQuantityRemarks
1Cabinet800×800×2200 (W×D×H), IP30KITOZER1 SetCold-rolled steel plate, thickness ≥2.0mm
2Air Circuit Breaker3P/4P, rated current 630A, breaking capacity 65kAKITOZER2 Sets1 for main power, 1 for standby power, intelligent type
3ATS Automatic Transfer Switch3P, rated current 630A, switching time ≤8msKITOZER1 SetSupport mains/generator switching
4Molded Case Circuit Breaker3P, rated current 250A/160A/100AKITOZER6 SetsBranch circuit protection
5Surge Protective DeviceClass I, nominal discharge current 25kA, maximum discharge current 50kAKITOZER1 SetThree-phase four-wire system with remote signaling
6Smart Electric MeterThree-phase four-wire, class 0.5S accuracy, RS485 communication supportedKITOZER2 Sets1 for main power, 1 for standby power
7Power Monitoring ModuleSupport 8-circuit current monitoring, Modbus-RTU protocolKITOZER1 SetCentralized monitoring and data upload
8Current TransformerRatio 600/5A, class 0.5 accuracyKITOZER6 Pcs3 for main circuits, 3 for standby circuits
9Busbar SystemCopper bar, 80×10mm specificationKITOZER1 SetConductivity ≥99.9%, insulation class B
10Control Switch220V with indicator lightKITOZER4 PcsMain and standby power switching control
11Indicator LightRed/Green, AC220VKITOZER6 PcsPower status indication
12Operation ButtonRed/Green, self-reset typeKITOZER4 PcsManual control and emergency stop
13Terminal Block2.5mm², Phoenix typeKITOZER2 GroupsControl circuit wiring
14Communication ModuleRS485 to Ethernet, Modbus-TCP protocolKITOZER1 SetSupport remote monitoring
15Heat Dissipation SystemAxial fan, AC220V, air volume ≥800m³/hKITOZER2 SetsAutomatic temperature control and overheating alarm
16Door Lock DeviceMechanical lock + electronic password lockKITOZER1 SetDual safety protection

4.2 Configuration List of Rack-mounted Row Head Cabinet (Model: KZ-PD-600-R)

No.Component NameSpecification & ModelBrandQuantityRemarks
1Cabinet600×1000×42U, standard 19-inchKITOZER1 SetCompatible with ETSI standards
2Main Circuit Breaker3P, rated current 400A, breaking capacity 50kAKITOZER1 SetIntelligent type with overload/short-circuit protection
3Molded Case Circuit Breaker3P, rated current 160A/100AKITOZER4 SetsBranch circuit protection
4Miniature Circuit Breaker2P, rated current 32A/20AKITOZER16 PcsServer cabinet power supply
5Intelligent PDU16A, 8 IEC C13 outputs with metering functionKITOZER8 Sets1 per cabinet, supporting independent monitoring
6Surge Protective DeviceClass II, nominal discharge current 15kAKITOZER1 SetThree-phase four-wire system
7Power Monitoring UnitSupport 16-circuit monitoring, LCD displayKITOZER1 SetReal-time display of each circuit status
8Communication ModuleDual Ethernet + RS485 portsKITOZER1 SetSupport DCIM system access
9Bus DuctRated current 400A, length 2mKITOZER1 SetSupport hot-swap expansion
10Control Panel7-inch touch screen with physical keysKITOZER1 SetLocal operation and parameter setting
11Status Indicator LightThree-color LED, DC24VKITOZER4 PcsPower/Fault/Alarm/Normal status indication

4.3 Configuration List of Wall-mounted Auxiliary Power Distribution Cabinet (Model: KZ-PD-400-W)

No.Component NameSpecification & ModelBrandQuantityRemarks
1Cabinet400×500×250 (W×D×H), IP30KITOZER1 SetWall-mounted installation
2Molded Case Circuit Breaker3P, rated current 250AKITOZER1 SetMain power protection
3Molded Case Circuit Breaker3P, rated current 100A/63AKITOZER4 SetsAir conditioning/fresh air system power supply
4Miniature Circuit Breaker1P+N, rated current 32A/20AKITOZER8 PcsLighting/socket circuits
5Contactor3P, rated current 63A, AC-3KITOZER2 SetsAir conditioner compressor control
6Thermal RelaySetting current 32A~63AKITOZER2 SetsMotor overload protection
7Surge Protective DeviceClass II, nominal discharge current 10kAKITOZER1 SetThree-phase + N-line protection
8Control Switch220V with indicator lightKITOZER2 PcsManual/automatic control
9Indicator LightRed/Green, AC220VKITOZER4 PcsPower/Operation/Fault indication
10Terminal Block2.5mm²KITOZER1 GroupControl circuit wiring

5. System Schematic Diagram

5.1 Single-power Power Distribution Cabinet Schematic

Mains Input (380V/50Hz) → Isolator Switch → Surge Protective Device (SPD) → Air Circuit Breaker (ACB) → Busbar System

                                           │

                                           ├─→ MCCB1 → Precision Air Conditioning Circuit

                                           ├─→ MCCB2 → UPS Input Circuit

                                           ├─→ MCCB3 → Lighting Circuit

                                           └─→ MCCB4 → Standby Expansion Circuit

                                                   │

                                                   └─→ MCB1~MCB8 → Branch Loads

5.2 Dual-power Automatic Transfer Power Distribution Cabinet Schematic

Mains Input 1 → Isolator Switch 1 → SPD1 → Air Circuit Breaker 1

                                     │

                                     ├─→ ATS Automatic Transfer Switch → Busbar System → Each Branch Circuit

                                     │

Mains Input 2 → Isolator Switch 2 → SPD2 → Air Circuit Breaker 2

       ↓

       Intelligent Monitoring Module → RS485/Ethernet → Monitoring Center

       ↓

       Current/Voltage Transformer → Smart Electric Meter → Energy Consumption Monitoring System

5.3 Row Head Cabinet Power Distribution Schematic

UPS Output → Main Molded Case Circuit Breaker → Busbar System

                               │

                               ├─→ Branch MCCB1 → Intelligent PDU1 → Cabinet 1 Load

                               ├─→ Branch MCCB2 → Intelligent PDU2 → Cabinet 2 Load

                               ├─→ Branch MCCB3 → Intelligent PDU3 → Cabinet 3 Load

                               └─→ Branch MCCBn → Intelligent PDUn → Cabinet n Load

                                       │

                                       └─→ Power Monitoring Module → Communication Interface → DCIM System

5.4 Key Technical Description

  1. Protection Coordination: Selective protection is realized among circuit breakers at all levels. Only the faulty circuit is cut off during short-circuit faults, with a protection selectivity coefficient ≥1.3.
  2. Transfer Logic: The ATS automatic transfer switch supports three modes: automatic switch & reclose, automatic switch & non-reclose, and mutual standby, with remote control support.
  3. Monitoring Function: All electrical parameters are uploaded to the monitoring module via RS485 bus, supporting real-time monitoring, historical data storage and fault alarm.
  4. Safety Design: Equipped with electrical and mechanical interlocks to prevent misoperation and ensure personnel safety.
data center power cabinet solution (4)

6. Product Technical Parameters

6.1 Basic Electrical Parameters

Parameter ItemTechnical IndexRemarks
Rated Voltage380V/220V, three-phase four-wire systemCompatible with 400V system
Rated Frequency50Hz/60HzUniversal design
Rated CurrentMain circuit: 250A~2500ABranch circuit: 16A~630AConfigured by model
Breaking CapacityMain circuit: 50kA~100kABranch circuit: 35kA~50kACompliant with IEC 60947-2 standard
Protection RatingIP20~IP40Selected according to installation environment
Insulation ClassMain circuit: Class BControl circuit: Class EHeat resistance temperature ≥130℃
Wiring ModeTop/bottom incoming line, left/right outgoing lineSupport multiple wiring methods
Installation MethodFloor-standing/wall-mounted/rack-mountedAdapt to different computer room layouts
Ambient Temperature-5℃~+40℃Operating temperature range
Relative Humidity5%~95%, non-condensingAdapt to humid environments
Altitude≤2000mCapacity derating required for higher altitude

6.2 Intelligent Monitoring Parameters

Parameter ItemTechnical IndexRemarks
Measurement AccuracyVoltage/Current: Class 0.5Power/Energy: Class 0.5SMeet metering standards
Measurement RangeVoltage: 0~500VCurrent: 0~2000APower: 0~1000kWWide-range measurement
Communication InterfaceRS485 (Modbus-RTU), Ethernet (Modbus-TCP)Dual communication backup supported
Communication Baud Rate9600~115200bpsAdaptive baud rate
Data StorageSupport 1-year historical data storagePower-off data retention
Alarm FunctionOvervoltage/Undervoltage/Overload/Short-circuit/Phase loss/Leakage/OverheatingAcoustic & light alarm + remote notification
Control ModeLocal control/Remote control/Automatic controlThree-level control authority
Display ModeLCD liquid crystal display, Chinese interfaceSupport data export

6.3 Transfer Device Parameters

Parameter ItemTechnical IndexRemarks
ATS Switching Time≤10msEnsure uninterrupted power supply for critical loads
Transfer ModeMains/Mains, Mains/Generator, Dual UPSMultiple switching modes
Mechanical Life≥10,000 timesMeet long-term operation requirements
Electrical Life≥5,000 timesOperation times under rated current
Transfer LogicAutomatic switch & reclose / Automatic switch & non-reclose / Mutual standbyProgrammable setting
Fault IndicationPower fault/Switching fault/Overload faultAccurate fault location

6.4 Protection Device Parameters

Parameter ItemTechnical IndexRemarks
Surge ProtectionClass I~III protectionNominal discharge current: 10kA~50kAGraded protection
Short-circuit ProtectionInstantaneous trip / Short-delay trip / Long-delay tripThree-section protection
Overload ProtectionInverse time characteristic, setting range: 0.8~1.2InAdapt to different loads
Leakage ProtectionOperating current: 30mA~500mAOperating time: ≤0.1sEnsure personal safety
Overvoltage ProtectionOperating value: 1.1~1.2 times rated voltagePrevent equipment overvoltage damage
Undervoltage ProtectionOperating value: 0.8~0.9 times rated voltagePrevent equipment low-voltage operation
Phase Loss ProtectionOperating time: ≤2sProtect three-phase equipment
data center power cabinet solution (3)

7. Product Application Scope

KITOZER computer room power distribution cabinets are widely applied in the following scenarios:

7.1 Data Center & Computer Room Scenarios

  • Large-scale data centers (Tier III~Tier IV)
  • Small and medium-sized enterprise computer rooms
  • Edge computing nodes
  • Cloud computing centers
  • Supercomputing centers
  • Financial industry disaster recovery computer rooms

7.2 Communication & Network Room Scenarios

  • Telecom operator computer rooms
  • Mobile/Unicom/Telecom base station rooms
  • Network switching centers
  • Data transmission nodes
  • IDC hosting computer rooms

7.3 Industrial & Commercial Room Scenarios

  • Industrial control centers
  • Automation computer rooms
  • Monitoring centers
  • Medical equipment rooms
  • Core computer rooms of financial institutions
  • Government agency data centers

7.4 Special Environment Room Scenarios

  • Explosion-proof computer rooms
  • Clean computer rooms
  • High-altitude computer rooms
  • Marine/offshore platform rooms
  • Vehicle-mounted mobile computer rooms
data center power cabinet solution (2)

8. Product Advantages

8.1 High-reliability Design

  • Redundant Configuration: Support N+1 and 2N redundancy with hot-swappable core components, MTTR ≤30 minutes
  • Strict Testing: All products pass 48-hour full-load operation test to ensure stable and reliable performance
  • High-quality Materials: Adopt high-conductivity copper bars (≥99.9%) and flame-retardant insulating materials to reduce fault risks
  • International Standards: Compliant with IEC, GB, UL and other domestic and international standards with CE certification

8.2 Intelligent Management

  • Full-scale Monitoring: Real-time monitoring of electrical parameters of all circuits, supporting remote diagnosis and early warning
  • Energy Consumption Analysis: Accurately measure energy consumption of each load, provide energy efficiency analysis reports to support energy saving and emission reduction
  • Remote Control: Realize remote switch control and parameter setting via network to reduce O&M costs
  • Diversified Data Interfaces: Support Modbus, SNMP, BACnet and other protocols, compatible with mainstream DCIM systems

8.3 Flexible Scalability

  • Modular Design: Adopt standardized modules for on-demand configuration and later expansion
  • Plug-and-play: New circuits can be added without power cut, supporting online capacity expansion
  • Busbar Expansion: Support busbar parallel connection to meet load growth demands
  • Customized Service: Provide customized solutions according to special computer room requirements

8.4 Safety Protection

  • Multi-level Protection: Full-range equipment protection including lightning protection, surge protection, overload and short-circuit protection
  • Electrical Isolation: Independent protection for each circuit to quickly isolate faults and avoid cross-impact on other equipment
  • Safety Interlock: Dual electrical and mechanical interlocks to prevent misoperation
  • Fault Alarm: Acoustic & light alarm plus remote notification for fast fault location

8.5 Energy Saving & Environmental Protection

  • Low-loss Design: Copper bar connection reduces line loss with high energy efficiency ratio
  • Intelligent Sleep Mode: Automatically enter energy-saving mode under light load to reduce no-load loss
  • Green Materials: Adopt environmentally friendly materials compliant with RoHS standards
  • Optimized Thermal Management: Optimized heat dissipation design reduces air conditioning energy consumption

9. Bidding Specification Parameters

The following are the bidding control parameters of KITOZER computer room power distribution cabinets, which can be used as technical requirements for bidding:

9.1 Basic Requirements

  1. The bid products must be originally manufactured by KITOZER, with manufacturer authorization letter and after-sales service commitment letter provided.
  2. Compliant with GB50174-2017 Code for Design of Data Centers and GB7251.1-2013 Low-voltage Switchgear and Controlgear Assemblies.
  3. Protection rating not lower than IP30, insulation class not lower than Class B.
  4. Main circuit breaking capacity ≥50kA, branch circuit breaking capacity ≥35kA.
  5. Support RS485/Modbus communication, compatible with mainstream DCIM systems.

9.2 Core Component Requirements

  1. Air Circuit Breaker (ACB): Intelligent type with three-section protection and energy metering function, breaking capacity ≥65kA.
  2. Molded Case Circuit Breaker (MCCB): Selective protection, breaking capacity ≥50kA, supporting thermal-magnetic trip/electronic trip.
  3. ATS Automatic Transfer Switch: Switching time ≤10ms, supporting mains/generator/dual-mains switching, equipped with manual operating mechanism.
  4. Surge Protective Device (SPD): Class I test type, nominal discharge current ≥20kA, maximum discharge current ≥50kA, with remote signaling function.
  5. Smart Electric Meter: Class 0.5S accuracy, capable of measuring three-phase voltage, current, power, energy and harmonic parameters, equipped with RS485 communication interface.

9.3 Monitoring & Management Requirements

  1. Support centralized monitoring and real-time electrical parameter detection for 8~32 circuits.
  2. The monitoring module supports Modbus-RTU/TCP protocol for seamless docking with DCIM systems.
  3. Equipped with Chinese operation interface, supporting local LCD display and remote Web access.
  4. Support historical data storage with storage capacity ≥1 year and data export function.
  5. Support fault early warning and automatic alarm via acoustic & light prompt, SMS and email notification.

9.4 Redundancy & Reliability Requirements

  1. Support N+1 redundant configuration and hot-swappable core components, MTBF ≥100,000 hours.
  2. ATS switching time ≤8ms to ensure uninterrupted power supply for critical loads.
  3. All protection devices have selectivity to ensure only faulty circuits are cut off during faults.
  4. Cabinet protection rating ≥IP30 with dustproof, moisture-proof and anti-animal functions.
  5. Comply with EMC requirements with strong anti-interference capability, certified by CE and UL.

9.5 Service & Warranty Requirements

  1. Provide ≥2-year warranty and lifelong maintenance service.
  2. Provide 7×24-hour technical support with fault response time ≤4 hours.
  3. Provide installation guidance, commissioning and professional training services.
  4. Support customized design to meet special computer room demands.
  5. Provide complete technical documents including schematic diagrams, wiring diagrams and user manuals.

10. Product Solutions

10.1 Small & Medium-sized Enterprise Computer Room Solution (Tier II)

Solution Overview

Provide cost-effective power supply and distribution solutions for small and medium-sized enterprise computer rooms to meet basic power supply reliability and management requirements.

System Architecture

  • Single mains input + UPS backup
  • 1 set of floor-standing main incoming power cabinet + 1 set of UPS output cabinet + multiple row head cabinets
  • All power cabinets and row head cabinets adopt KITOZER brand with centralized monitoring support

Core Configuration

  1. KZ-PD-600 Main Incoming Power Cabinet: Equipped with air circuit breaker, ATS, surge protective device and smart electric meter
  2. KZ-PD-600-UPS Output Cabinet: Equipped with molded case circuit breaker and intelligent monitoring module
  3. KZ-PD-600-R Row Head Cabinet: 1 set per row, supporting power supply for 8~12 cabinets
  4. KITOZER Intelligent PDU: 1 set per cabinet, supporting remote monitoring

Solution Advantages

  • High cost performance, fully meeting the demands of small and medium-sized computer rooms
  • Flexible configuration supporting later capacity expansion
  • Intelligent monitoring reduces operation and maintenance costs
  • Provide basic power protection and management functions

10.2 Large-scale Data Center Solution (Tier IV)

Solution Overview

Provide 2N redundant power supply and distribution solutions for large-scale data centers to meet zero-interruption requirements of core businesses.

System Architecture

  • Dual mains + dual UPS + diesel generator, 2N redundant configuration
  • 2 sets of independent parallel-operating power cabinet systems
  • Full series of KITOZER products including main incoming cabinet, UPS input cabinet, UPS output cabinet, row head cabinet and auxiliary cabinet

Core Configuration

  1. 2 sets of KZ-PD-1000 Dual-power Main Incoming Cabinets, mutual standby with automatic ATS switching
  2. 2 sets of KZ-PD-1000-UPS Input Cabinets, each matching one UPS system
  3. 2 sets of KZ-PD-1000-UPS Output Cabinets, each matching one UPS system
  4. 2 sets of KZ-PD-800-R Row Head Cabinets per row with dual-power input and redundant configuration
  5. KITOZER Intelligent Monitoring System: Centralized monitoring of all power cabinets and DCIM system access support

Solution Advantages

  • 2N redundancy ensures zero power interruption, fully compliant with Tier IV standards
  • Full-scale monitoring for real-time power system operation status awareness
  • Fast fault isolation to reduce impact scope
  • Modular design supports online capacity expansion

10.3 Edge Computing Node Solution

Solution Overview

Provide compact, efficient and easy-to-manage power supply and distribution solutions for edge computing nodes, adapting to narrow space and remote management requirements.

System Architecture

  • Single mains + local UPS, rack-mounted design
  • KZ-PD-600-R Integrated Row Head Cabinet: Integrating incoming power, UPS, output and monitoring functions
  • Support remote monitoring and management for unattended operation scenarios

Core Configuration

  1. KZ-PD-600-R Integrated Row Head Cabinet: Equipped with ATS, UPS, molded case circuit breaker, intelligent PDU and monitoring module
  2. KITOZER Rack-mounted UPS: 10kVA~30kVA, hot-swappable
  3. KITOZER Intelligent PDU: 1 set per cabinet, supporting remote control and monitoring
  4. KITOZER Power Monitoring Software: Support Web and mobile APP monitoring

Solution Advantages

  • Integrated design saves space, adapting to narrow space of edge nodes
  • Plug-and-play for rapid deployment
  • Remote management reduces operation and maintenance costs
  • High reliability ensures stable operation of edge computing businesses

10.4 Financial Industry Disaster Recovery Computer Room Solution

Solution Overview

Provide high-reliability and high-safety power supply and distribution solutions for financial industry disaster recovery computer rooms to meet core business disaster recovery demands.

System Architecture

  • Dual mains + dual UPS + diesel generator, 2N redundant configuration
  • Full series of KITOZER power cabinets including main incoming cabinet, UPS cabinet, row head cabinet and auxiliary cabinet
  • Independent monitoring system supporting docking with financial industry supervision platforms

Core Configuration

  1. 2 sets of KZ-PD-1250 Dual-power Main Incoming Cabinets with automatic switching and synchronization functions
  2. 4 sets of KZ-PD-1250-UPS Cabinets, 2 sets of UPS systems with 2-unit redundancy per system
  3. 2 sets of KZ-PD-800-R Row Head Cabinets per row with dual-power input and independent protection
  4. KITOZER Intelligent Monitoring Platform: Multi-level authority management compliant with financial industry safety standards
  5. KITOZER Fault Early Warning System: Real-time power system status monitoring and potential fault early warning

Solution Advantages

  • 2N redundancy ensures zero interruption, meeting stringent financial industry standards
  • Full-range safety protection from lightning protection to overload protection
  • Strict authority management compliant with financial industry supervision requirements
  • Intelligent early warning reduces fault risks and improves system availability

11. Product Application Cases

11.1 Case 1: XX Bank Data Center (Tier IV)

Project Overview

  • Project Name: XX Bank Disaster Recovery Data Center Construction
  • Room Scale: 200 standard cabinets, total load 10MW
  • Construction Standard: Tier IV, zero-interruption operation required
  • Location: Shanghai

Solution

Adopt KITOZER 2N redundant power supply and distribution solution:

  1. 4 sets of KZ-PD-2000 main incoming power distribution cabinets with dual mains + diesel generator configuration
  2. 8 sets of KZ-PD-1600-UPS cabinets with 2N redundant configuration
  3. 20 sets of KZ-PD-800-R row head cabinets, 2 per row with redundant configuration
  4. KITOZER intelligent monitoring system for centralized management and remote control

Application Effects

  • System availability reaches 99.999%, fully meeting Tier IV standards
  • Intelligent monitoring reduces O&M costs by 30%
  • Fast fault isolation ensures no major power supply accidents
  • Excellent energy-saving effect with PUE reduced below 1.3

11.2 Case 2: XX Internet Company Cloud Computing Center (Tier III)

Project Overview

  • Project Name: XX Internet Company Cloud Computing Center Expansion
  • Room Scale: 500 standard cabinets, total load 25MW
  • Construction Standard: Tier III, N+1 redundancy
  • Location: Hangzhou

Solution

Adopt KITOZER N+1 redundant power supply and distribution solution:

  1. 2 sets of KZ-PD-2500 main incoming power cabinets with dual mains + ATS configuration
  2. 6 sets of KZ-PD-2000-UPS cabinets with N+1 redundant configuration
  3. 50 sets