1. System Introduction
The KITOZER computer room wiring auxiliary system is a standardized, fully-matched, and highly compatible structured wiring auxiliary material system. Tailored for core IT infrastructure scenarios such as data centers, computer rooms, and network rooms, it provides full-link wiring support covering the work area, horizontal subsystem, vertical backbone subsystem, equipment room, and campus subsystem. Complying with international standards including TIA-942 and ISO/IEC 11801, the system adopts a modular, high-density and lightweight design, fully compatible with copper and optical fiber transmission media. It adapts to full-bandwidth network transmission requirements from Gigabit, 10 Gigabit, 40Gbps to 400Gbps, comprehensively ensuring high performance, high reliability, high flexibility and easy maintainability of the computer room wiring system.
As the “vascular support system” for stable computer room network operation, the KITOZER wiring auxiliary system not only provides basic physical connection support, but also builds a stable and safe operating environment for core IT equipment such as switches, servers and storage devices through standardized cable arrangement, efficient electromagnetic shielding protection and optimized computer room airflow and heat dissipation structure. It effectively reduces the overall Total Cost of Ownership (TCO) of the computer room, extends the service life of wiring and terminal equipment, perfectly meets the stringent operation and maintenance requirements of modern data centers for 7×24-hour uninterrupted and high-load operation, and serves as a core supporting solution for the construction, upgrading and renovation of standardized and intelligent computer rooms.

2. System Composition
Based on years of industry technical accumulation, the KITOZER computer room wiring auxiliary system integrates full-category wiring supporting products to build seven core component systems, forming an end-to-end, integrated and scalable complete wiring solution that fully covers the full-scene demands of computer room wiring construction, operation and maintenance, protection and expansion.
| Component Category | Core Products | Functional Description |
| Transmission Media | Copper cables (Cat.6/Cat.6A/Cat.8), optical cables (OM3/OM4/OM5 multi-mode, OS2 single-mode) | Build high-speed and stable data transmission channels, adapt to network communication demands of different bandwidth levels, transmission distances and scenarios, and ensure low-loss signal transmission |
| Connection Devices | Network sockets, patch panels, jumpers, couplers, optical fiber adapters, terminal boxes | Realize standardized termination, flexible jumping and cross interconnection of cables, optimize link structure, reduce signal crosstalk and insertion loss, and ensure stable link transmission |
| Cable Management | Cable trays, bridge frames, cable organizers, cable fixers, flame-retardant cable ties, cable arrangement accessories | Standardize cable routing and layered wiring, optimize computer room airflow organization, reduce messy cable accumulation, greatly lower operation and maintenance difficulty, and support flexible later expansion |
| Protection Devices | Cable sheaths, corrugated pipes, optical fiber protection sleeves, waterproof connectors, dust-proof plugs | Provide all-round cable protection against physical pulling, extrusion and wear, isolate moisture, dust and electromagnetic interference, extend cable service life, and improve system stability |
| Identification System | Waterproof cable labels, equipment identification plates, professional label printers, colored identification strips | Realize accurate classification and identification of cables, ports and equipment, quickly locate link information, greatly improve operation and maintenance troubleshooting efficiency, and achieve standardized operation and maintenance management |
| Installation Accessories | Suspension rods, fixed brackets, fastening connectors, grounding terminals, grounding cables | Ensure stable installation and neat arrangement of the entire wiring system, build a complete electrical grounding system, eliminate static accumulation, and improve system electromagnetic compatibility |
| Special Auxiliary Materials | Fireproof putty, sealant, anti-static floor accessories, flame-retardant plugging materials | Meet special environmental requirements such as fire prevention, static resistance and dust-proof sealing of computer rooms, fill gaps in wiring construction, and improve the overall safety and environmental adaptability of the computer room |
3. System Classification
The KITOZER computer room wiring auxiliary system adopts refined classification based on three dimensions: transmission medium, application subsystem and functional characteristics. With complete categories and clear classification, it supports flexible selection and matching according to computer room scale, bandwidth requirements and application scenarios, adapting to various new construction, renovation and expansion projects.
3.1 Classification by Transmission Medium
| Category | Product Series | Technical Characteristics | Application Scenarios |
| Copper Cable Wiring Auxiliaries | Full series of Cat.6/Cat.6A/Cat.8 auxiliaries | Complete grades covering bandwidth from Gigabit to 40Gbps, with shielded and unshielded models optional, flame-retardant and low-smoke zero-halogen alternatives available, featuring stable transmission and strong anti-interference performance | Enterprise office computer rooms, campus networks, data centers, core switch interconnection, high-density terminal access scenarios |
| Optical Fiber Wiring Auxiliaries | OM3/OM4/OM5 multi-mode, OS2 single-mode auxiliaries | Multi-mode adapts to short-distance high-speed transmission, single-mode supports long-distance wide-area transmission, with low insertion loss and high return loss, compatible with 10G/40G/100G/400G high-speed links | Data center backbone links, metropolitan area networks, cross-building interconnection, high-definition video transmission, high-performance computing scenarios |
3.2 Classification by Application Scenario
1. Work Area Subsystem Auxiliaries: Including network panels, information sockets, desktop jumpers, terminal adapters, etc., focusing on terminal equipment access, adapting to network connection of office terminals, monitoring equipment, terminal hosts and other devices, with convenient installation and clear identification.
2. Horizontal Subsystem Auxiliaries: Covering horizontal copper cables, line pipes, small bridge frames and fixed accessories, used to connect work areas and management rooms, realizing standardized wiring of floor terminal points with neat routing and convenient construction.
3. Management Subsystem Auxiliaries: Including various patch panels, cabinet cable organizers, jumpers and identification systems, realizing centralized cable storage, arrangement and flexible jumping in computer rooms, facilitating daily operation, maintenance and link adjustment.
4. Vertical Backbone Subsystem Auxiliaries: Adapted to large-pair copper cables, backbone optical cables, shaft-specific bridge frames and fixed accessories, connecting floor management rooms and core equipment rooms, undertaking the backbone transmission task of the entire building network with excellent stability and compression resistance.
5. Equipment Room Subsystem Auxiliaries: Including high-density patch panels, ODF optical fiber distribution frames, cabinet cable trays and large-scale cable management equipment, adapting to core equipment cluster connection in computer rooms and meeting the deployment requirements of high-density, high-bandwidth and high-reliability core links.
6. Campus Subsystem Auxiliaries: Including outdoor special optical cables, waterproof connectors, lightning protection grounding devices and outdoor protective sleeves, adapting to network interconnection between parks and multiple buildings, with waterproof, lightning-proof, anti-aging and outdoor weather resistance characteristics.
3.3 Classification by Functional Characteristics
1. High-Density Series: Designed for high-density deployment in data centers, supporting 48-port copper cable or 96-core optical fiber connection per 1U space, greatly saving cabinet space, improving computer room space utilization, and adapting to large-scale terminal access scenarios.
2. Shielded Series: Adopting a multi-layer shielding structure with excellent EMI/RFI electromagnetic shielding performance, effectively resisting external electromagnetic interference to ensure pure signal transmission, suitable for high-sensitivity scenarios such as industrial computer rooms, financial trading computer rooms and medical equipment computer rooms.
3. Flame-Retardant Series: Complying with UL94 V-0 flame retardant standard in full line, made of flame-retardant, low-smoke and non-toxic materials, self-extinguishing on fire without flame spread, greatly improving computer room fire safety level and meeting computer room fire protection acceptance specifications.
4. Intelligent Series: Integrated with electronic labels and link sensors, compatible with intelligent wiring management systems, realizing cable asset statistics, real-time link status monitoring and automatic fault early warning, adapting to intelligent and unattended operation and maintenance computer rooms.

4. System Configuration List (Brand: KITOZER)
The following is the standardized configuration list of computer room wiring auxiliary materials, divided into three categories: copper cable, optical fiber, cable management and installation auxiliaries, which can be flexibly adjusted according to computer room point scale, bandwidth requirements and scenario characteristics.
4.1 Copper Cable Wiring Auxiliaries Configuration List
| No. | Product Name | Model | Specification Parameters | Unit | Remarks |
| 1 | Cat.6 Unshielded Twisted Pair | KT-C6-UTP | 4-pair 23AWG solid copper conductor, CMR flame retardant, 250MHz bandwidth, compliant with TIA-568-C.2 standard | Meter | Supports full 1Gbps transmission, compatible with 10Gbps in short distance, suitable for conventional enterprise office scenarios |
| 2 | Cat.6A Shielded Twisted Pair | KT-C6A-STP | 4-pair 23AWG solid oxygen-free copper conductor, overall aluminum foil shielding, LSZH low-smoke zero-halogen sheath, 500MHz bandwidth | Meter | Stable 10Gbps transmission within 100m, anti-electromagnetic interference, suitable for computer rooms with complex electromagnetic environments |
| 3 | Cat.8 Shielded Twisted Pair | KT-C8-STP | 4-pair 22AWG solid copper conductor, double-layer shielding structure, 2000MHz ultra-high bandwidth, LSZH sheath | Meter | Supports 40Gbps high-speed transmission with 30m transmission distance, suitable for core equipment interconnection and high-performance computing scenarios |
| 4 | 24-Port Cat.6 Unshielded Patch Panel | KT-PP24-C6-UTP | 1U standard rack height, precision IDC wire-terminating terminals, compatible with T568A/B dual wire sequence, metal shell | Piece | Comes with integrated cable management frame, compatible with 50μm wire diameter, durable plugging and stable signal |
| 5 | 48-Port Cat.6A Shielded Patch Panel | KT-PP48-C6A-STP | 2U height, fully shielded metal shell, built-in grounding terminal, front and rear dual-direction cable management structure | Piece | High-density deployment design, effectively reducing link crosstalk, suitable for large-scale point deployment in data centers |
| 6 | Cat.6 Unshielded Jumper | KT-JC6-UTP-2M | 2-meter standard length, RJ45-RJ45 interface, multi-strand twisted conductor, flexible and wear-resistant sheath | Piece | Used for jumping connection between work area terminals and patch panels, and between patch panels and equipment rooms |
| 7 | Network Information Socket | KT-WP-C6 | 86-type universal panel, single/dual port optional, Cat.6 certified module, built-in dust cover | Piece | Equipped with colored identification strips to quickly distinguish link purposes, dust-proof and anti-oxidation |
4.2 Optical Fiber Wiring Auxiliaries Configuration List
| No. | Product Name | Model | Specification Parameters | Unit | Remarks |
| 1 | OM4 Multi-Mode Optical Fiber | KT-F-OM4-12 | 12-core, 50/125μm core/cladding specification, tight buffer structure, LSZH low-smoke zero-halogen sheath | Meter | Supports 100Gbps high-speed transmission with effective transmission distance of 150m, suitable for computer room backbone links |
| 2 | OS2 Single-Mode Optical Fiber | KT-F-OS2-24 | 24-core, 9/125μm low-water-peak core, anti-aging structure, LSZH flame-retardant sheath | Meter | Supports 400Gbps ultra-high-speed transmission with transmission distance over 10km, suitable for long-distance interconnection |
| 3 | 1U 24-Port LC Optical Fiber Patch Panel | KT-ODF24-LC | 1U standard rack, 24-port LC duplex adapter, built-in storable fusion splicing tray, modular structure | Piece | Comes with pigtails and couplers, supporting high-density optical fiber termination and standardized management |
| 4 | MTP/MPO Pre-Terminated Optical Fiber Component | KT-MTP-12-3M | 12-core MTP to LC interface, 3-meter standard length, OM4 multi-mode, ultra-low insertion loss | Set | No on-site fusion splicing required for rapid deployment, greatly shortening construction cycle and reducing labor loss |
| 5 | LC-LC Optical Fiber Jumper | KT-FJ-LC-LC-5M | 5-meter length, LC duplex interface, OM4 multi-mode, bend-insensitive design, low loss | Piece | Used for optical fiber link jumping in equipment rooms, suitable for high-speed transmission scenarios with stable performance |
| 6 | LC Optical Fiber Adapter | KT-FA-LC | LC duplex structure, high-precision ceramic sleeve, insertion loss ≤0.2dB, durable plugging | Piece | Compatible with full-series LC interface optical fiber equipment, suitable for various optical fiber link docking |
| 7 | Optical Fiber Protection Sleeve | KT-FT-10 | 10mm inner diameter, corrugated compression-resistant structure, UL94 V-0 flame-retardant material, wear-resistant and pull-resistant | Meter | Provides all-round protection for optical fiber cables to avoid mechanical damage during construction and operation and maintenance |
4.3 Cable Management and Installation Auxiliaries Configuration List
| No. | Product Name | Model | Specification Parameters | Unit | Remarks |
| 1 | Aluminum Alloy Cable Tray | KT-CR-400 | 400mm width, 100mm height, 2.0mm wall thickness, aviation aluminum alloy material, complete with connecting accessories | Meter | Load capacity ≥100kg/m, anti-corrosion and rust-proof, suitable for standardized overhead wiring deployment in computer rooms |
| 2 | 1U Cabinet Cable Organizer | KT-MG-1U | 1U standard height, high-strength flame-retardant plastic, arc-shaped flow-guiding cable management structure | Piece | Supports horizontal and vertical bidirectional cable management, optimizes cabinet airflow and reduces heat dissipation energy consumption |
| 3 | Snap-Fit Cable Fixer | KT-WC-10 | 10mm adaptive width, stainless steel material, snap-fit and drill-free design | Piece | Firmly fixes internal cabinet cables to avoid looseness and mess, occupying only 1U space |
| 4 | Flame-Retardant Nylon Cable Tie | KT-ZD-300 | 300mm standard length, nylon material, UL94 V-0 flame retardant grade, tensile and wear-resistant | Pack | 100 pieces per pack, used for cable binding and arrangement, compliant with computer room fire protection standards |
| 5 | Waterproof Cable Label | KT-LB-25 | 25mm width, waterproof, oil-proof and tear-proof material, compatible with special label printers | Roll | Aging-resistant and fade-proof, meeting long-term labeling requirements of computer rooms |
| 6 | 8mm Suspension Rod Bracket Set | KT-HD-8 | 8mm diameter galvanized steel suspension rod, complete with fixing bolts and buckles, load capacity ≥50kg | Set | Used for hoisting and fixing cable trays and bridge frames, stable and corrosion-resistant |
| 7 | A-Grade Fireproof Putty | KT-FM-500 | 500g per pack, A-grade flame retardant, high temperature resistant, strong plasticity and tight plugging | Pack | Used for plugging holes of bridge frames and line pipes to block fire spread and meet fire acceptance standards |

5. System Schematic Diagram
5.1 Computer Room Wiring System Topology Diagram
| Plain Text [Work Area Subsystem] ↔ [Horizontal Subsystem] ↔ [Management Subsystem] ↔ [Vertical Backbone Subsystem] ↔ [Equipment Room Subsystem] ↔ [Campus Subsystem] Complete Link Connection Logic: Terminal devices (computers/servers/monitors/industrial control devices) ↔ KITOZER network information socket ↔ KITOZER copper/optical fiber transmission medium ↔ KITOZER patch panel/ODF optical fiber distribution frame ↔ KITOZER standard jumper ↔ core network devices (switches/routers) ↔ KITOZER backbone cable ↔ computer room core equipment cluster ↔ KITOZER outdoor optical cable ↔ equipment in other building computer rooms in the park |
5.2 Internal Cabinet Wiring Schematic Diagram
| Plain Text Top of Cabinet: KITOZER aluminum alloy cable tray ↔ 1U cable organizer ↔ copper/optical fiber patch panel ↔ standard jumper ↔ access switch Middle of Cabinet: Server/storage/industrial control equipment ↔ snap-fit cable fixer ↔ waterproof cable label ↔ grounding terminal system Bottom of Cabinet: Special computer room bridge frame ↔ cable protection sheath ↔ neat wiring under anti-static floor ↔ equipment grounding summary |
5.3 Optical Fiber Connection Schematic Diagram
| Plain Text Outdoor backbone optical cable ↔ fixed and stored in optical fiber terminal box ↔ professional fusion splicing construction ↔ KITOZER optical fiber pigtail ↔ KITOZER optical fiber adapter ↔ KITOZER optical fiber jumper ↔ computer room core optical fiber switch/transmission equipment |
6. Product Technical Parameters
6.1 Copper Cable Series Technical Parameters
| Technical Index | Cat.6 Unshielded | Cat.6A Shielded | Cat.8 Shielded | Test Standard |
| Transmission Bandwidth | 250MHz | 500MHz | 2000MHz | TIA-568.2-D |
| Max Transmission Rate | 1Gbps(100m)/10Gbps(55m) | 10Gbps(100m) | 40Gbps(30m) | IEEE 802.3 |
| Conductor Specification | 4-pair 23AWG solid copper | 4-pair 23AWG solid copper | 4-pair 22AWG solid copper | IEC 60228 |
| Insulation Material | HDPE High-Density Polyethylene | HDPE High-Density Polyethylene | HDPE High-Density Polyethylene | UL 44 |
| Shielding Type | Unshielded | Overall Aluminum Foil Shield (FTP) | Double Composite Shield (SFTP) | IEC 61156 |
| Sheath Material |