1. System Introduction
The KITOZER computer room wiring system is a standardized structured wiring solution that complies with international and domestic standards including TIA/EIA-568-D and GB/T 50311-2016. Specially designed for key information infrastructure such as data centers, computer rooms and network rooms, it provides full-link physical connection and management services covering from core computer rooms to terminal devices. Adhering to the core design concepts of high reliability, high scalability and easy manageability, the system adopts a modular architecture and supports the hybrid deployment of copper cables and optical fibers. It meets high-speed data transmission requirements ranging from Gigabit to 400G, adapts to future network upgrades and business expansion, and lays a solid physical foundation for the stable operation of IT systems.

2. System Composition
The KITOZER computer room wiring system consists of six core subsystems, forming a complete end-to-end connection solution:
| Subsystem | Core Components | Functional Positioning |
| Work Area Subsystem | Information sockets, jumpers, adapters | Realizes the connection between terminal devices (PCs/servers/network devices) and information points, supporting plug-and-play access |
| Horizontal Subsystem | Cat.6/Cat.7 copper cables, OM3/OM4 multi-mode optical fibers, metal cable trays | Connects work areas and management rooms to realize high-speed data transmission in horizontal areas |
| Vertical Backbone Subsystem | Large-pair copper cables, single-mode/multi-mode optical fibers, computer room bridge frames | Connects core computer rooms and floor management rooms, serving as the “main artery” for data transmission |
| Management Subsystem | Copper cable patch panels, ODF optical fiber distribution frames, cable organizers, jumpers | Enables cable termination, jumping and standardized management, supporting flexible configuration adjustment and rapid fault troubleshooting |
| Equipment Room Subsystem | Core switches, server cabinets, optical fiber splicing boxes, high-density patch panels | Serves as the installation area for core network equipment, realizing high-speed data exchange and centralized equipment management |
| Campus Subsystem | Outdoor optical cables, optical fiber splice closures, optical fiber splicing accessories | Establishes communication links between different buildings and supports long-distance high-speed data transmission |
3. System Classification
3.1 Classification by Transmission Medium
Copper Cable Wiring System: Adopts Cat.6/Cat.6A/Cat.7 shielded/unshielded twisted pairs, supporting transmission rates from Gigabit to 40Gbps. It is applicable to short-distance (≤100m) high-speed data connections such as server cluster interconnection and network device interworking.
Optical Fiber Wiring System:
– Multi-mode Optical Fiber (OM3/OM4/OM5): Supports 10G to 400G high-speed transmission, suitable for short-distance (≤300m) high-bandwidth connections inside computer rooms.
– Single-mode Optical Fiber (OS2): Supports ultra-long-distance (≤10km) high-speed transmission, applied to cross-floor and cross-building interconnection scenarios.
Hybrid Wiring System: Adopts a combined deployment of copper cables and optical fibers. Copper cables are used for terminal access connections, while optical fibers undertake backbone transmission tasks. It balances transmission performance and construction cost, perfectly adapting to complex computer room operating environments.
3.2 Classification by Application Scenario
Standard Computer Room Wiring System: Suitable for small and medium-sized enterprise computer rooms, supporting 10Gbps transmission. Equipped with basic bridge frames and wiring distribution equipment, it fully meets conventional daily IT operation demands.
High-Density Data Center Wiring System: Adopts high-density patch panels and MPO pre-terminated optical fiber systems, supporting 40G/100G/400G ultra-high-speed transmission, adapting to high-power-density cabinet deployment in large-scale data centers.
Modular Computer Room Wiring System: Supports rapid on-site deployment and flexible capacity expansion, applicable to new-type infrastructure such as container data centers and integrated modular computer rooms.
Shielded Wiring System: Features full-link shielding design including shielded cables, shielded patch panels and shielded modules. It is applicable to scenarios with severe electromagnetic interference, such as industrial control computer rooms and medical equipment rooms.
3.3 Classification by Management Mode
Traditional Wiring System: Adopts manual management mode, realizing asset management and equipment fault troubleshooting through label identification and document records.
Intelligent Wiring System: Integrated with electronic patch panels, intelligent jumpers and professional management software. It supports real-time port status monitoring, automatic link identification and remote centralized management, reducing fault positioning time to within 30 seconds.

4. System Configuration List (Brand: KITOZER)
4.1 Computer Room Bridge Frame Series
| Product Name | Model | Specification | Material | Application Scenario |
| Trough-type Computer Room Bridge Frame | KT-QJ-C | 100×50/200×100/300×150/400×200mm | Hot-dip galvanized steel sheet / aluminum alloy, thickness: 1.2-2.0mm | Main routing of computer room cables, protecting cables from mechanical damage |
| Ladder-type Computer Room Bridge Frame | KT-QJ-T | 300×100/400×150/500×200mm, cross bar spacing: 150mm | Hot-dip galvanized steel sheet | Server areas requiring high ventilation and heat dissipation, scenarios with large cable load capacity |
| Grid-type Computer Room Bridge Frame | KT-QJ-W | 300×100/400×150mm, grid size: 50×50mm | Galvanized steel wire | Flexible wiring scenarios, supporting multi-directional branching and arbitrary installation |
| Bridge Frame Accessories | KT-QJ-PJ | Supporting elbows, tees, crosses, brackets, suspension rods | Hot-dip galvanized steel sheet | Connection and fixation of bridge frames, adapting to complex wiring routing requirements |
4.2 Metal Trunking Series
| Product Name | Model | Specification | Material | Application Scenario |
| Enclosed Metal Trunking | KT-XC-F | 50×25/100×50/150×75mm, thickness: 0.8-1.2mm | Galvanized steel sheet | Horizontal area wiring, protecting cables from external impact and damage |
| Open-type Metal Trunking | KT-XC-K | 100×50/150×75/200×100mm, with heat dissipation holes | Galvanized steel sheet | Connection between work areas and management rooms, facilitating cable addition, removal and daily maintenance |
| Metal Trunking Accessories | KT-XC-PJ | Elbows, tees, joints, fixing parts | Galvanized steel sheet | Trunking connection and fixation, adapting to various complex installation environments |
4.3 Patch Panel Series
| Product Name | Model | Specification | Performance Parameters | Application Scenario |
| 24-Port Cat.6 Unshielded Patch Panel | KT-PP-24U6 | 19-inch 1U, 24 ports | Contact resistance ≤20mΩ, insulation resistance ≥500MΩ, plugging times ≥1000 cycles | Horizontal area copper cable termination, supporting Gigabit network transmission |
| 48-Port Cat.6A Shielded Patch Panel | KT-PP-48S6A | 19-inch 2U, 48 ports | Shielding efficiency ≥90dB@1GHz, supporting 10Gbps high-speed transmission | High-density server areas and scenarios with complex electromagnetic interference |
| 24-Port LC Duplex ODF Optical Fiber Distribution Frame | KT-ODF-24LC | 19-inch 1U, 24 LC duplex ports | Insertion loss ≤0.3dB, return loss ≥50dB | Multi-mode/single-mode optical fiber termination, supporting 10G high-speed transmission |
| 12-Port MPO High-Density ODF Frame | KT-ODF-12MPO | 19-inch 1U, 12 MPO ports | Compatible with OM4/OM5 multi-mode optical fibers, supporting 40G/100G transmission | Core areas of data centers for high-density optical fiber interconnection |
4.4 Optical Fiber Splicing Accessories Series
| Product Name | Model | Specification | Performance Parameters | Application Scenario |
| Optical Fiber Splicing Box | KT-RJ-8/12/24 | 8/12/24 cores, wall-mounted/rack-mounted | IP65 protection grade, working temperature: -20℃~+60℃ | Protection for optical fiber splicing points, applicable to indoor computer room and outdoor environments |
| Optical Fiber Quick Connector | KT-FC-LC/SC | LC/SC interface, single-mode/multi-mode optional | Insertion loss ≤0.5dB, return loss ≥45dB | Quick optical fiber connection without splicing equipment, suitable for emergency wiring scenarios |
| Optical Fiber Jumper | KT-FJ-LC/SC | LC-LC/SC-SC interface, single-mode/multi-mode, length: 1-10m | Insertion loss ≤0.3dB, bending radius ≥10 times of fiber outer diameter | Optical fiber connection between equipment, adapting to various interface types |
| Optical Fiber Coupler | KT-FC-LC/SC | LC/SC single-mode/multi-mode | Insertion loss ≤0.2dB, plugging repeatability ≥1000 cycles | Optical fiber port expansion and interconnection between different network devices |
4.5 Wiring Auxiliary Material Series
| Product Name | Model | Specification | Material/Characteristics | Application Scenario |
| Cat.6 Unshielded Twisted Pair | KT-C6-UTP | 4 pairs 8 cores, outer diameter: 6.0mm | Oxygen-free copper conductor, cross isolation structure, PVC/LSZH sheath, CMR flame retardant grade | Horizontal subsystem wiring, supporting Gigabit network transmission |
| Cat.7 Shielded Twisted Pair | KT-C7-STP | 4 pairs 8 cores, double-layer shielding structure | Oxygen-free copper conductor, TPE insulation, LSZH low-smoke zero-halogen sheath | High-density data center wiring, supporting 40Gbps transmission with strong anti-interference performance |
| OM4 10G Multi-mode Optical Fiber | KT-F-OM4 | 50/125μm core/cladding, 12 cores, outer diameter: 2.0mm | Low-loss fiber core, bandwidth ≥4700MHz·km | Short-distance (≤550m) 10G transmission, such as inter-floor network interconnection |
| OS2 Single-mode Optical Fiber | KT-F-OS2 | 9/125μm core/cladding, 12 cores, outer diameter: 2.0mm | Low-loss fiber core, maximum transmission distance ≥10km | Long-distance transmission scenarios such as cross-building interconnection |
| Cable Organizer | KT-LXQ | 19-inch 1U, metal structure | Modular design, supporting front and rear bidirectional cable management | Management subsystem, for cable sorting and fixation to improve wiring neatness |
| Information Socket | KT-TO-6A | 86-type panel, single/dual port optional, Cat.6/Cat.6A compliant | Phosphor bronze gold-plated contact, contact resistance ≤20mΩ | Work area subsystem, serving as terminal device connection points |

5. System Schematic Diagram
5.1 System Topology Structure
| Plain Text [Terminal Devices] — [Work Area Information Socket] — [Horizontal Subsystem (Metal Trunking + Cat.6/Cat.6A Copper Cable / OM4 Optical Fiber)] — [Floor Management Room (Patch Panel + Cable Organizer + Switch)] | [Vertical Backbone Subsystem (Bridge Frame + OS2 Single-mode / OM4 Multi-mode Optical Fiber)] | [Core Equipment Room (High-density ODF + Core Switch + Server Cabinet)] — [Campus Subsystem (Outdoor Optical Cable)] — [Other Buildings] |
5.2 Typical Connection Schematic
1. Copper Cable Connection Path: Server → Cat.6 Jumper → Information Socket → Cat.6 Twisted Pair → Copper Cable Patch Panel → Jumper → Network Switch
2. Optical Fiber Connection Path: Core Switch → LC Optical Fiber Jumper → ODF Optical Fiber Distribution Frame → OM4 Multi-mode Optical Fiber → Splicing Box → Optical Fiber Splicing → OM4 Multi-mode Optical Fiber → ODF Optical Fiber Distribution Frame → LC Optical Fiber Jumper → Access Switch
3. Management Room Connection: Horizontal Cable → Patch Panel → Cable Organizer → Jumper → Network Device, realizing flexible link jumping and systematic management

6. Product Technical Parameters
6.1 Technical Parameters of Bridge Frames and Metal Trunkings
| Parameter Item | Technical Requirements | Test Standard |
| Material | Hot-dip galvanized steel sheet (zinc layer ≥275g/m²) or 6063-T5 aluminum alloy | GB/T 2694-2018 |
| Load Capacity | Uniform load ≥2000N/m², concentrated load ≥500N | GB/T 21648-2008 |
| Fire Resistance Grade | Metal material, Class A non-combustible | GB 8624-2012 |
| Protection Grade | IP40 (enclosed type), IP20 (open type) | GB 4208-2017 |
| Surface Treatment | Hot-dip galvanized / electrostatic spraying, coating thickness ≥60μm | GB/T 18684-2014 |
| Dimensional Tolerance | Length deviation ≤±3mm, width/height deviation ≤±1mm | GB/T 12770-2012 |
6.2 Technical Parameters of Copper Cables and Optical Fibers
| Product Type | Key Parameters | Technical Indicators |
| Cat.6 Unshielded Twisted Pair | Transmission Frequency/Bandwidth | 250MHz, supporting Gigabit transmission |
| Insertion Loss | ≤21.0dB@100m, 250MHz | |
| Return Loss | ≥24.0dB@250MHz | |
| NEXT (Near-End Crosstalk) | ≥44.3dB@250MHz | |
| Cat.6A Shielded Twisted Pair | Transmission Frequency/Bandwidth | 500MHz, supporting 10Gbps transmission |
| Insertion Loss | ≤21.0dB@100m, 500MHz | |
| Return Loss | ≥23.0dB@500MHz | |
| Shielding Efficiency | ≥90dB@1-400MHz | |
| OM4 Multi-mode Optical Fiber | Core/Cladding Diameter | 50/125μm |
| Transmission Distance | 10G: 550m, 40G: 100m | |
| Bandwidth | ≥4700MHz·km | |
| Insertion Loss | ≤0.3dB/km | |
| OS2 Single-mode Optical Fiber | Core/Cladding Diameter | 9/125μm |
| Transmission Distance | 10G: 40km, 40G: 2km | |
| Attenuation | ≤0.4dB/km@1310nm, ≤0.3dB/km@1550nm |
6.3 Technical Parameters of Patch Panels and Connection Devices
| Parameter Item | Copper Cable Patch Panel | Optical Fiber Distribution Frame (ODF) | Information Socket |
| Contact Resistance | ≤20mΩ | – | ≤20mΩ |
| Insulation Resistance | ≥500MΩ | ≥10^12Ω | ≥500MΩ |
| Plugging Times | ≥1000 cycles | – | ≥1000 cycles |
| Insertion Loss | – | ≤0.3dB (LC Interface) | – |
| Return Loss | – | ≥50dB (Single-mode), ≥30dB (Multi-mode) | – |
| Shielding Efficiency | ≥90dB@1GHz (Shielded Type) | – | ≥90dB@1GHz (Shielded Type) |
| Working Temperature | -20℃~+60℃ | -20℃~+60℃ | -20℃~+60℃ |

7. Product Application Scope
7.1 Data Center Scenarios
Large-scale Cloud Data Center: Adopts high-density optical fiber wiring (MPO+LC duplex) to support 400G high-speed interconnection, adapting to high-power-density cabinet deployment and large-scale cloud service operation.
Enterprise-level Data Center: Implements hybrid deployment of copper cables and optical fibers, adapting to virtualization and cloud computing operating environments to provide highly reliable network connection services.
Edge Data Center: Features modular wiring design, supporting rapid deployment and flexible capacity expansion, perfectly adapting to space-limited edge computing scenarios.
7.2 Industry Application Scenarios
| Industry | Application Characteristics | Recommended Configuration |
| Finance | High security, low latency, 24×7 uninterrupted operation | Cat.7 shielded wiring + intelligent management system, supporting rapid fault positioning |
| Medical | Anti-electromagnetic interference, high reliability, compliant with medical industry standards | Shielded wiring + LSZH low-smoke zero-halogen sheath, adapting to medical equipment room environments |
| Government | High security, manageable performance, long-term stable operation | Cat.6/Cat.6A wiring + intelligent patch panels, supporting asset management and operation audit |
| Education | Cost-effective, easy maintenance, supporting multimedia teaching services | Cat.6 unshielded wiring + standard management system, adapting to campus network operation |
| Manufacturing | Anti-interference, durable, adapting to harsh industrial environments | Armored cables + metal trunkings, suitable for factory workshops and industrial control computer rooms |
7.3 Special Application Scenarios
Modular Computer Room: Adopts prefabricated wiring solutions with factory pre-installation and on-site rapid assembly, greatly shortening project construction cycles.
Container Data Center: Equipped with customized bridge frames and trunkings, adapting to narrow space and anti-seismic requirements, supporting rapid mobile deployment.
Shielded Computer Room: Full-link shielding design including shielded bridge frames, shielded cables and shielded patch panels, meeting strict EMC (Electromagnetic Compatibility) requirements.
8. Product Advantages
8.1 Performance Advantages
High-Speed Transmission: Supports Cat.6/Cat.6A/Cat.7 copper cable (Gigabit to 40G) and OM3/OM4/OS2 optical fiber (10G to 400G) transmission, fully meeting network upgrading demands for the next 10 years.
Low-Loss Design: Copper cables adopt cross isolation and tight sheath structure, while optical fibers adopt low-loss fiber cores, ensuring high-quality signal transmission and reducing bit error rate effectively.
Strong Anti-Interference Capability: The full range of shielded products (bridge frames, trunkings, cables, patch panels) provide ≥90dB shielding efficiency, adapting to severely electromagnetic interference scenarios.
8.2 Reliability Advantages
High Durability: Core components such as patch panels and information sockets adopt phosphor bronze gold-plated contacts, with plugging life ≥1000 cycles, ensuring long-term stable service life.
Fire Safety: All products comply with UL94-V0 or IEC 60332-1 flame retardant standards; partial products adopt LSZH low-smoke zero-halogen materials to reduce fire hazards.
Strong Environmental Adaptability: The system operates stably in the temperature range of -20℃~+60℃, adapting to various climatic conditions and complex computer room environments.
8.3 Management Advantages
Modular Expansion: Supports on-demand capacity expansion, reducing initial investment cost and lowering the overall Total Cost of Ownership (TCO).
Intelligent Operation & Maintenance: Optional electronic patch panels and management software support real-time link monitoring, remote management and fault early warning, improving maintenance efficiency by 50%.
Standardized Interface: Complies with international universal standards, supporting compatibility with equipment of different brands and reducing equipment replacement and maintenance costs.
8.4 Installation & Maintenance Advantages
Rapid Deployment: Modular components and plug-and-play design shorten on-site installation time by 30% and reduce labor costs.
Flexible Adjustment: The management subsystem supports rapid link jumping and configuration modification, adapting to dynamic business adjustment demands.
Easy Maintenance: Standard label identification and complete documentation, combined with intelligent management system, reduce fault positioning time to within 30 seconds.
9. Bid Control Parameters
9.1 General Technical Requirements
1. The system must comply with international and domestic standards including TIA/EIA-568-D, GB/T 50311-2016 and ISO/IEC 11801, with valid third-party test reports provided.
2. The copper cable wiring system must pass FLUKE DSX-8000 certification testing, and the optical fiber system must pass FLUKE OF-500 certification testing, with complete test reports supplied.
3. All products must be equipped with certificate of origin and quality guarantee, with a warranty period of no less than 15 years and lifelong technical support services.
4. The system provides end-to-end link performance guarantee and 25-year application compatibility guarantee to support future network upgrades.
9.2 Itemized Bid Control Parameters
9.2.1 Computer Room Bridge Frames and Metal Trunkings
– Material: Hot-dip galvanized steel sheet with zinc layer thickness ≥65μm, compliant with GB/T 2694-2018 standard.
– Load Capacity: Uniform load ≥2000N/m², concentrated load ≥500N without obvious deformation.
– Fire Resistance Grade: Class A non-combustible compliant with GB 8624-2012, with official test reports.
– Protection Grade: Enclosed bridge frames/trunkings ≥IP40, meeting computer room dust-proof requirements.
9.2.2 Copper Cables and Connection Devices
– Cat.6/Cat.6A Copper Cables: Pass third-party testing and comply with ANSI/TIA-568.2-D standard with qualified crosstalk and return loss indicators.
– Patch Panels/Information Sockets: Contact resistance ≤20mΩ, insulation resistance ≥500MΩ, plugging times ≥1000 cycles, with test reports provided.
– Shielding Performance (Shielded Series): Shielding efficiency ≥90dB@1GHz, compliant with IEC 61587 standard.
9.2.3 Optical Fibers and Accessories
– Multi-mode Optical Fiber: OM4 grade, bandwidth ≥4700MHz·km, 10G transmission distance ≥550m, with test reports provided.
– Single-mode Optical Fiber: OS2 grade, attenuation ≤0.4dB/km@1310nm, maximum transmission distance ≥10km.
– Optical Fiber Connection Devices: Insertion loss ≤0.3dB, return loss ≥50dB (single-mode)/30dB (multi-mode), compliant with Telcordia GR-326 standard.
10. Product Solution Cases
10.1 High-Density Data Center Wiring Solution
Core Requirements: Support 400G high-speed interconnection, adapt to high-power-density cabinet deployment, and ensure high system reliability and easy manageability.
Solution Deployment:
1. Backbone Transmission: Adopt MPO high-density optical fibers (12-core/24-core) + OS2 single-mode optical fibers to support 400G ultra-high-speed interconnection for core switch and server connection.
2. Horizontal Area: Deploy Cat.6A shielded twisted pairs and metal trunkings to support 10Gbps stable transmission, meeting connection demands of servers and storage devices.
3. Management System: Equip with 1U 48-port LC duplex high-density ODF frames and intelligent electronic patch panels to realize real-time port monitoring and remote intelligent management.
4. Bridge Frame System: Combine ladder-type and grid-type bridge frames to optimize cabinet ventilation and heat dissipation, supporting flexible cable deployment and standardized management.
Implementation Key Points:
– Adopt BIM modeling technology to pre-plan wiring routes, reducing material waste by 15%.
– Implement color marking management: Blue copper cables for data transmission, purple copper cables for storage links; orange for multi-mode optical fibers, yellow for single-mode optical fibers to improve maintenance efficiency.
– Apply pre-terminated optical fiber components to shorten on-site construction cycle and reduce splicing loss.
10.2 Enterprise-level Computer Room Wiring Solution
Core Requirements: Cost-effective, easy to maintain, support flexible business expansion, and adapt to virtualization and cloud computing operating environments.
Solution Deployment:
1. Backbone Transmission: Adopt OM4 multi-mode optical fibers + Cat.6 unshielded twisted pairs to support 10G high-speed transmission for core layer and access layer interconnection.
2. Horizontal Area: Deploy Cat.6 unshielded twisted pairs and enclosed metal trunkings to provide stable Gigabit connection for desktop terminals and network equipment.
3. Management System: Equip with standard 1U 24-port LC duplex ODF frames and 24-port Cat.6 patch panels, supporting manual management and label identification maintenance.
4. Bridge Frame System: Combine trough-type and ladder-type bridge frames to meet wiring and heat dissipation demands of different functional areas.
Implementation Key Points:
– Adopt modular design and reserve 30% redundant ports and cables to support future business expansion.
– Implement layered wiring: Separate strong current and weak current lines with a horizontal spacing of ≥30cm, and isolate crossing positions with metal partitions.
– Equip with standard cable organizers to ensure neat wiring and improve daily maintenance convenience.
10.3 Shielded Computer Room Wiring Solution
Core Requirements: Meet EMC electromagnetic compatibility standards, prevent internal information leakage, and adapt to high-security and strong-interference operating environments.
Solution Deployment:
1. Full-Link Shielding: Deploy shielded bridge frames, shielded trunkings, Cat.7 shielded twisted pairs, shielded patch panels and shielded information sockets to achieve ≥90dB full-link shielding efficiency.
2. Grounding System: Adopt single-point grounding design with grounding resistance ≤1Ω to ensure effective grounding of shielding layers and optimize anti-interference performance.
3. Optical Fiber System: Adopt armored OS2 single-mode optical fibers to provide physical protection and anti-interference capability for long-distance transmission links.
4. Management System: Equip with shielded ODF frames and shielded patch panels to ensure complete shielding links and avoid signal leakage.
Implementation Key Points:
– Ensure continuous shielding layers without breakpoints to maintain consistent overall shielding efficiency.
– Use dedicated shielded jumpers for end-to-end shielding performance integration to reduce electromagnetic radiation.
– Conduct professional EMC testing after construction to verify system anti-interference capability and information security.
11. Product Application Cases
11.1 Case 1: Fintech Center of Bank of China Head Office
Project Background: Build an international first-class financial data center to support high-concurrency transaction processing and big data analysis, requiring 24×7 uninterrupted and zero-error operation.
Solution Configuration:
– Backbone Transmission: 12-core OS2 single-mode optical fibers + 24-core OM4 multi-mode optical fibers, supporting 400G high-speed interconnection.
– Horizontal Area: Cat.6A shielded twisted pairs + ladder-type bridge frames, supporting 10Gbps stable transmission for server and storage device connections.
– Management System: 1U 48-port LC duplex high-density ODF frames + intelligent electronic patch panels, realizing rapid fault positioning within 30 seconds.
– Bridge Frame System: Combined trough-type and ladder-type bridge frames to meet differentiated wiring demands