KITOZER
KITOZER

KITOZER Conductive Fabric-over-Foam Gasket

Product Overview

The KITOZER conductive fabric-over-foam gasket is a versatile EMI shielding seal built from a soft polyurethane foam core wrapped in a durable conductive fabric knit. The outer fabric is silver plated or nickel copper plated on a polyester substrate, providing high electrical conductivity while the soft foam core compresses easily under low closing force. This combination delivers excellent shielding continuity across the mating seams of enclosures, equipment cabinets, and shielded room panels without damaging painted surfaces. It is widely chosen where light touch, low closure pressure, and reliable environmental sealing are required together.

A seam that leaks electromagnetic energy is one of the most common causes of radiated emission failures. Even a small gap in a metal enclosure acts as an antenna at high frequencies. The fabric-over-foam gasket fills that gap with a conductive path that remains compliant over the full closure cycle. Because the foam compresses instead of springing back rigidly, thin sheet metal doors and lightweight plastic covers seal without distortion, which is essential for consumer and medical housings where appearance and weight matter as much as compliance.

Technical Specifications

Shielding effectiveness greater than 100 dB over 10 MHz to 1 GHz and greater than 70 dB to 10 GHz. Surface resistance below 0.05 ohm per square. Compression set below 10 percent at 50 percent deflection. Operating temperature minus 40 to plus 85 degrees Celsius. Standard cross sections from 2 mm by 2 mm up to 20 mm by 20 mm, supplied in strips or die-cut frames. Adhesive backing available for quick installation. RoHS and REACH compliant, UL 94 HFI flammability rated.

The silver-plated fabric offers the highest conductivity and best corrosion resistance, while the nickel copper variant suits cost-sensitive general equipment. The polyurethane core recovers from compression and resists the outgassing that affects older silicone foams. The pressure-sensitive adhesive backing bonds to painted and powder-coated surfaces as long as the surface is clean. Cross sections are held to tight tolerances so that assembly compression is predictable across production runs.

Applications

Install along the mating flanges of server chassis, rack doors, outdoor telecom cabinets, medical device housings, and avionics equipment enclosures. It is also used between plastic covers and internal metal frames where an electrically continuous seam is needed to meet FCC or CE emission limits. The soft foam cushions against dust and light moisture while the fabric handles the shielding duty.

Outdoor telecom cabinets use it because it seals against rain splash while providing the radio frequency continuity that radio gear demands. Medical equipment uses it because the low closure force does not stress thin stainless housings and the material tolerates disinfectant cleaning. Server chassis use it to close the top cover seam that would otherwise radiate switching noise. Die-cut frames are also used around display windows and connector cutouts where a continuous conductive border is required.

Advantages and Features

Low compression force means thin sheet metal doors and lightweight plastic covers seal without deformation. The conductive fabric resists abrasion and repeated cycling better than bare metal foam, and the silver plating offers corrosion resistance in humid environments. The adhesive backed version cuts installation time on the assembly line, and the wide range of cross sections allows designers to match the exact groove depth and compression target.

Compared with fingerstock, fabric-over-foam is quieter on closure and gentler on painted surfaces, and it costs a fraction. Compared with solid metal gaskets, it tolerates uneven flanges and absorbs slight misalignment. The material can be cut to length on site and applied with hand pressure, so prototyping and small production runs need no special tooling.

Installation and Maintenance

Clean the mating surface of grease and oxidation before applying. Ensure 30 percent to 70 percent compression at closure to maintain conductivity. Avoid over-compression beyond 75 percent, which permanently deforms the foam. Inspect seals at annual maintenance for fabric wear and replace if the conductive layer is abraded. Keep solvents away from the adhesive joint.

During assembly, plan the groove or bond surface so the gasket compresses uniformly at corners; corners are where gaskets usually fail first. Use a knife or die to cut clean corners rather than stretching the strip around a bend. In high-vibration equipment, check the adhesive bond at the first scheduled service. If the fabric shows a worn or shiny path, replace the section before it causes an emission failure. When designing the groove, leave a small compression stop so the gasket is never fully crushed, which extends gasket life and keeps the shielding stable across the product lifetime. Choosing the right cross section up front avoids field returns and keeps the enclosure within its EMC limits for years of service.

Price

From $0.8 per meter. Contact plus 86 13922289957 for custom cut lengths and die-cut frames. Bulk pricing for production runs available.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top