Table of Contents
Toggle1. System Overview
The KITOZER container data center is a prefabricated, modular and integrated data center infrastructure reconstructed based on standard ISO shipping containers. It prefabricates and pre-commissions sub-systems including IT cabinets, power supply & distribution, cooling, fire protection, monitoring and wiring in factory to form an independent operable unit. It boasts core advantages such as rapid deployment, flexible capacity expansion, high energy efficiency, reliable safety and convenient mobility. As an innovative alternative to traditional machine rooms, it adapts to three core scenarios: standard prefabrication, data center and edge computing, and meets diversified IT deployment demands including outdoor, remote, emergency, high-density and low-latency scenarios. Its PUE can be as low as 1.25, with customizable standard specifications of 20ft and 40ft. The full product line supports OEM/ODM, confidential production and spot delivery.
2. System Composition
Adopting a modular integrated architecture, the KITOZER container data center features deeply integrated and independently controllable sub-systems, with core components listed below:
- Container Enclosure System Standard 20/40ft ISO shipping containers made of Corten A steel with five-layer protection (PIR fire-resistant insulation layer, anti-static PVC floor, copper earthing system, etc.), IP55 protection grade, anti-seismic, waterproof, corrosion-resistant and flame-retardant, with a service life of ≥25 years.
- IT Cabinet System 19-inch standard 42U cabinets with load capacity ≥1000kg, supporting cold/hot aisle isolation for high-density deployment of servers, storage and network equipment.
- Power Supply & Distribution System Online UPS with N+1/2N redundancy, precision power distribution cabinets, intelligent PDUs, lightning protection & earthing, and spare generator interface. It supports 380V/400V three-phase input, with backup power duration optional from 10 to 60 minutes.
- Cooling & Heat Dissipation System In-row precision air conditioners, air-cooled/liquid-cooled heat dissipation, FreeCooling energy-saving modules and isolated cold/hot air ducts. It can operate under extreme ambient temperatures ranging from -40℃ to +55℃, with cooling capacity optional from 6kW to 20kW.
- Fire Protection & Security System Smoke/temperature sensing detection, FM200/aerosol fire suppression, electromagnetic access control, RFID card swiping, IP surveillance cameras and intrusion detection, with linked alarm and remote disposal functions.
- Environmental Monitoring System Sensors for temperature & humidity, smoke, water immersion, access control and energy consumption as well as equipment status. Real-time remote monitoring via Web/APP, compatible with SNMP and Modbus protocols to connect to BMS systems.
- Integrated Cabling System Fiber/copper cabling, vertical trunking, cable managers and fiber distribution frames, reserved high-speed network interfaces supporting 10G/40G network transmission.
- Auxiliary System Lighting, emergency power supply, earthing system, ventilation & air exchange and noise reduction treatment to guarantee stable operation and safe maintenance of the data center.
3. System Classification
3.1 Standard Prefabricated Container Data Center
- Specifications: Mainly 20ft (6.1m×2.4m×2.6m), 40ft optional
- Power Density: ≤5kW per cabinet, total capacity 50–100kW
- Core Features: Standardized design, low cost, easy deployment, basic protection configuration, satisfying storage and basic operation of general IT equipment
- Applicable Scenarios: Small & medium enterprise machine rooms, branch offices, remote sites, temporary offices, emergency backup data centers
3.2 Data Center Container Data Center
- Specifications: Mainly 40ft (12.2m×2.4m×2.6m), supporting multi-container cluster stacking
- Power Density: 5–15kW per cabinet, total capacity 100–500kW for high-density computing deployment
- Core Features: Redundant architecture (N+1/2N for UPS & air conditioners), liquid cooling, intelligent monitoring, high protection grade, PUE as low as 1.25, supporting 7×24-hour uninterrupted operation
- Applicable Scenarios: Internet data centers, cloud computing nodes, core machine rooms for finance & government, headquarters of large enterprises, disaster recovery centers
3.3 Edge Computing Container Data Center
- Specifications: Compact 10/20ft design with lightweight structure for easy transportation and rapid deployment
- Power Density: 3–8kW per cabinet, total capacity 30–80kW, optimized for low-latency local data processing
- Core Features: Miniaturized, low power consumption, online deployment within 48 hours, local data processing, adaptable to harsh outdoor environments, compatible with 5G base stations
- Applicable Scenarios: 5G edge nodes, IoT, industrial internet, smart transportation, smart parks, telemedicine, outdoor monitoring centers
4. System Schematic Diagrams
4.1 Overall Architecture Schematic
Taking standard ISO shipping container as the carrier, the interior is divided into five functional zones: IT equipment zone, power supply & distribution zone, cooling zone, fire protection zone and monitoring zone. All zones are interconnected via the integrated cabling system, with external access to municipal power, optical fiber and cooling water (liquid-cooled models). It realizes independent “plug-and-play” operation and supports capacity expansion via multi-container clusters.
4.2 Power Supply & Distribution Schematic
Municipal power input → precision power distribution cabinet → redundant UPS → intelligent PDU → IT equipment. Meanwhile, the UPS is connected to a spare generator interface to achieve seamless switching during power outages. Lightning protection and earthing modules are deployed throughout the system to prevent lightning strikes and static electricity from damaging equipment.
4.3 Cooling System Schematic
Outdoor unit → precision/in-row air conditioner → isolated cold/hot air ducts → heat dissipation for IT cabinets → hot air exhaust. The FreeCooling module utilizes natural cold sources for energy conservation and automatically switches to mechanical cooling under high ambient temperatures, maintaining internal temperature at 22±2℃ and relative humidity at 40%–60%.
4.4 Monitoring System Schematic
Temperature/humidity/smoke/water immersion/access control sensors → data collector → monitoring host → remote Web/APP terminals. The system links fire protection, air conditioning and access control equipment, and automatically triggers alarms and emergency disposal (e.g., fire suppression, power cut, door unlocking) upon abnormalities.
5. Full System Configuration List (Low / Medium / High Tiers, KITOZER Brand)
5.1 Low-Tier Configuration List (20ft Standard Prefabricated Type)
表格
| No. | Product Name | Model & Specs | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Container Enclosure | KITOZER-20S | 20ft (6100×2438×2591mm), Corten A steel, IP55, fire insulation layer, anti-static floor, floor load ≥800kg/㎡ | 1 | Set | KITOZER | Standard prefabricated model with basic protection |
| 2 | IT Cabinet | KITOZER-R42S | 42U, 600×800×2000mm, load ≥800kg, mesh door, 19-inch standard | 2 | Set | KITOZER | For basic IT equipment storage |
| 3 | Online UPS | KITOZER-UPS-10K | 10kVA/8kW, single-in single-out, 15min backup, efficiency ≥90% | 1 | Set | KITOZER | Basic power guarantee |
| 4 | Precision Power Distribution Cabinet | KITOZER-PDB-63S | 63A input, 380V, SPD lightning protection, overload protection, 4 output circuits | 1 | Set | KITOZER | Basic power distribution management |
| 5 | Intelligent PDU | KITOZER-PDU-12S | 12×C13 ports, 16A, remote switching, voltage/current monitoring | 2 | Set | KITOZER | Cabinet power distribution |
| 6 | In-row Precision Air Conditioner | KITOZER-AC-6S | 6kW cooling capacity, air-cooled, 220V, temp adjustable 18–30℃, RH 40%–70% | 1 | Set | KITOZER | Basic heat dissipation |
| 7 | Smoke Detector | KITOZER-SD-S | Photoelectric type, alarm temp 55℃, linked with fire suppression | 2 | Pcs | KITOZER | Fire detection |
| 8 | Aerosol Fire Suppression Unit | KITOZER-FG-5S | 5kg, auto activation, residue-free, eco-friendly | 1 | Set | KITOZER | Basic fire suppression |
| 9 | Electromagnetic Access Control | KITOZER-AC-S | Card + password, electromagnetic lock, power-off door release | 1 | Set | KITOZER | Basic security access |
| 10 | Temperature & Humidity Sensor | KITOZER-TH-S | Temp -20℃~60℃, RH 0%–100%, RS485 output | 2 | Pcs | KITOZER | Environmental monitoring |
| 11 | Surveillance Camera | KITOZER-CAM-S | 1080P, IR night vision, outdoor waterproof | 1 | Set | KITOZER | Video monitoring |
| 12 | Integrated Cabling | KITOZER-CAB-S | Cat6 UTP, single-mode fiber, cable managers, trunking | 1 | Batch | KITOZER | Basic wiring system |
5.2 Medium-Tier Configuration List (20ft Edge Computing Type)
表格
| No. | Product Name | Model & Specs | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Container Enclosure | KITOZER-20E | 20ft (6100×2438×2591mm), Corten A steel, IP55, five-layer protection, Grade 8 seismic resistance, floor load ≥1000kg/㎡, noise reduction treatment | 1 | Set | KITOZER | Edge computing model with enhanced outdoor performance |
| 2 | IT Cabinet | KITOZER-R42E | 42U, 600×1000×2000mm, load ≥1000kg, cold/hot aisle isolation, mesh + glass door | 3 | Set | KITOZER | High-density equipment deployment |
| 3 | Online UPS | KITOZER-UPS-20K | 20kVA/16kW, three-in single-out, N+1 redundancy, 30min backup, efficiency ≥93% | 2 | Set | KITOZER | Redundant power supply for edge scenarios |
| 4 | Precision Power Distribution Cabinet | KITOZER-PDB-100E | 100A input, 380V, Class III lightning protection, smart electricity meter, 8 output circuits, remote monitoring | 1 | Set | KITOZER | Intelligent power distribution management |
| 5 | Intelligent PDU | KITOZER-PDU-16E | 16 ports (12×C13+4×C19), 32A, remote switch/monitoring, SNMP protocol | 3 | Set | KITOZER | Intelligent power distribution |
| 6 | In-row Precision Air Conditioner | KITOZER-AC-10E | 10kW cooling capacity, air-cooled + FreeCooling, 380V, temp 22±2℃, RH 40%–60%, redundant design | 2 | Set | KITOZER | Energy-saving heat dissipation for low-power edge use |
| 7 | Combined Temp & Smoke Detector | KITOZER-THD-E | Combined temperature & smoke sensing, alarm temp 50℃, linked with fire suppression & air conditioning | 4 | Pcs | KITOZER | High-precision fire detection |
| 8 | FM200 Fire Suppression Unit | KITOZER-FM-10E | 10L, auto/manual activation, clean gas, residue-free, eco-friendly | 1 | Set | KITOZER | High-efficiency fire suppression |
| 9 | RFID Access Control + Surveillance System | KITOZER-AC-E | RFID card + password + fingerprint, electromagnetic lock, camera linkage; 4-channel 1080P IR cameras, NVR storage | 1 | Set | KITOZER | Linked intelligent security |
| 10 | Environmental Monitoring Host | KITOZER-MON-E | Full monitoring of temp/humidity/smoke/water immersion/access control/energy consumption, Web/APP remote monitoring, Modbus protocol | 1 | Set | KITOZER | Centralized monitoring & management |
| 11 | Water Immersion Sensor | KITOZER-WL-E | Electrode type, water leakage alarm, RS485 output | 2 | Pcs | KITOZER | Water leak prevention monitoring |
| 12 | Integrated Cabling | KITOZER-CAB-E | Cat6 STP, 10G single-mode fiber, high-density cable managers, enclosed flame-retardant trunking | 1 | Batch | KITOZER | High-speed low-latency wiring for edge computing |
5.3 High-Tier Configuration List (40ft Data Center Type)
表格
| No. | Product Name | Model & Specs | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Container Enclosure | KITOZER-40D | 40ft (12192×2438×2591mm), Corten A steel, IP55, military-grade protection, Grade 9 seismic resistance, floor load ≥1200kg/㎡, anti-corrosion/flame-retardant/noise reduction, 25-year service life | 1 | Set | KITOZER | Data center model for high-density clusters |
| 2 | IT Cabinet | KITOZER-R42D | 42U, 800×1200×2200mm, load ≥1500kg, cold/hot aisle isolation, smart lock, cooling fans | 8 | Set | KITOZER | Ultra-high-density computing deployment |
| 3 | Online UPS | KITOZER-UPS-60K | 60kVA/48kW, three-in three-out, 2N redundancy, 60min backup, efficiency ≥96%, parallel redundancy | 4 | Set | KITOZER | Dual redundant power for 7×24h operation |
| 4 | Precision Power Distribution Cabinet | KITOZER-PDB-250D | 250A input, 380V, Class IV lightning protection, intelligent energy monitoring, 16 output circuits, remote control, redundant busbar | 2 | Set | KITOZER | High-end power distribution management |
| 5 | Intelligent PDU | KITOZER-PDU-24D | 24 ports (16×C13+8×C19), 63A, remote switch/monitor/alarm, SNMP/Modbus, redundant power input | 8 | Set | KITOZER | Premium intelligent power distribution |
| 6 | In-row Liquid-Cooled Precision Air Conditioner | KITOZER-AC-20D | 20kW cooling capacity, dual liquid/air cooling mode, FreeCooling, 380V, temp 22±1℃, RH 45%–55%, N+2 redundancy, PUE ≤1.25 | 4 | Set | KITOZER | High-efficiency energy-saving cooling for high-density loads |
| 7 | Very Early Smoke Aspiration Detector | KITOZER-SD-D | Aspiration type, ultra-early warning, sensitivity 0.01–0.3dB/m, linked with fire suppression/AC/access control | 6 | Pcs | KITOZER | Ultra-early fire pre-warning |
| 8 | FM200 Pipe Network Fire Suppression System | KITOZER-FM-30D | 30L pipe network type, auto/manual/emergency activation, zone-based fire suppression, clean residue-free eco-friendly gas | 2 | Set | KITOZER | Zoned high-efficiency fire suppression |
| 9 | Intelligent Security System | KITOZER-SEC-D | 4-in-1 access control (face recognition/RFID/password/fingerprint), linked with 8-channel 4K IR cameras, NVR + cloud storage, intrusion detection, electronic fence | 1 | Set | KITOZER | Military-grade security protection |
| 10 | Environmental Monitoring System | KITOZER-MON-D | Full monitoring of temp/humidity/smoke/water immersion/access control/energy consumption/equipment status, Web/APP/ large-screen remote monitoring, AI early warning, BMS integration | 1 | Set | KITOZER | Intelligent monitoring & early warning |
| 11 | Spare Generator Interface | KITOZER-GEN-D | 400V three-phase interface, automatic switching, compatible with 200kW generators | 1 | Set | KITOZER | Long-duration power outage backup |
| 12 | Integrated Cabling | KITOZER-CAB-D | Cat7 STP, 40G single-mode fiber, intelligent cable management, enclosed flame-retardant trunking, fiber distribution frames | 1 | Batch | KITOZER | Premium high-speed wiring system |
6. Full Product Technical Specifications
6.1 Container Enclosure Technical Specifications
- Dimensions: 20ft (6100×2438×2591mm), 40ft (12192×2438×2591mm), custom sizes available
- Material: Corten A weathering steel, thickness 4–6mm, anti-corrosion & rust-proof, service life ≥25 years
- Protection Grade: IP55, waterproof, dustproof, moisture-proof, operable under -40℃~+55℃ extreme ambient temperatures
- Structural Strength: Grade 8–9 seismic resistance, floor load 800–1200kg/㎡, stackable, hoistable and transportable
- Thermal Insulation: 50mm thick PIR fire-resistant insulation layer, thermal conductivity ≤0.022W/(m·K), energy-saving thermal isolation
- Anti-Static Treatment: Anti-static PVC floor, surface resistance 10⁶–10⁹Ω to prevent static damage to equipment
- Earthing System: Copper earthing strip, earthing resistance ≤4Ω to guarantee electrical safety
6.2 IT Cabinet Technical Specifications
- Standard Size: 42U; dimensions: 600×800×2000mm (low tier), 600×1000×2000mm (medium tier), 800×1200×2200mm (high tier)
- Load Capacity: 800kg (low), 1000kg (medium), 1500kg (high); high-strength frame structure
- Material: High-quality cold-rolled steel plate, thickness 1.5–2.0mm, electrostatic spray coating, anti-corrosion & wear-resistant
- Heat Dissipation: Mesh door (low tier), cold/hot aisle isolation (medium & high tiers), top/side cooling fans, ventilation efficiency ≥85%
- Accessories: 19-inch standard mounting rails, cable managers, trays, blanking panels, smart locks (high tier only)
6.3 Online UPS Technical Specifications
- Rated Capacity: 10kVA/8kW (low), 20kVA/16kW (medium), 60kVA/48kW (high)
- Input Voltage: 220V single-in single-out (low), 380V three-in single-out (medium), 380V three-in three-out (high)
- Backup Duration: 15min (low), 30min (medium), 60min (high); long-duration models customizable
- Efficiency: ≥90% (low), ≥93% (medium), ≥96% (high), high energy efficiency
- Redundancy: No redundancy (low), N+1 redundancy (medium), 2N redundancy (high) for stable power supply
- Protection Functions: Overvoltage, undervoltage, overload, short-circuit and overtemperature protection, automatic bypass switching
6.4 Precision Air Conditioner Technical Specifications
- Cooling Capacity: 6kW (low), 10kW (medium), 20kW (high)
- Cooling Mode: Air-cooled (low), air-cooled + FreeCooling (medium), dual liquid/air cooling (high)
- Operating Voltage: 220V (low), 380V (medium & high)
- Temperature & Humidity Control: Temp 18–30℃ (low), 22±2℃ (medium), 22±1℃ (high); RH 40%–70% (low), 40%–60% (medium), 45%–55% (high)
- Redundancy: Non-redundant (low), N+1 redundant (medium), N+2 redundant (high)
- PUE Value: ≤1.5 (low), ≤1.3 (medium), ≤1.25 (high), superior energy efficiency
6.5 Fire Protection System Technical Specifications
- Smoke Detectors: Photoelectric (low), combined temp & smoke (medium), ultra-early aspiration type (high); alarm temperature 50–55℃, response time ≤3s
- Fire Suppression Units: 5kg aerosol (low), 10L FM200 (medium), 30L pipe network FM200 (high); auto/manual activation, fire suppression time ≤10s, residue-free and eco-friendly
6.6 Monitoring System Technical Specifications
- Temperature & Humidity Sensors: Operating range -20℃~60℃, RH 0%–100%, accuracy ±0.5℃, ±3% RH, RS485 output
- Water Immersion Sensors: Electrode type, detection distance 0–5m, leakage alarm response time ≤2s
- Surveillance Cameras: 1080P (low & medium), 4K (high); IR night vision range 30–50m, outdoor waterproof, H.265 encoding
- Monitoring Host: Web/APP remote monitoring support, data storage ≥1 year, Modbus/SNMP compatible, AI abnormality early warning (high tier only)
7. Product Application Scope
7.1 Container Enclosure Application Scope
- General Scenarios: Small & medium machine rooms, branch offices, remote sites, temporary offices, emergency backup data centers
- Data Center Scenarios: Internet data centers, cloud computing nodes, core machine rooms for finance & government, large enterprise headquarters, disaster recovery centers
- Edge Computing Scenarios: 5G edge nodes, IoT, industrial internet, smart transportation, smart parks, telemedicine, outdoor monitoring centers
- Special Scenarios: Oilfields, mines, field exploration, military bases, post-disaster reconstruction, temporary machine rooms for large-scale events
7.2 IT Cabinet Application Scope
- Storage & deployment of servers, storage devices, network switches, routers, firewalls, optical modules and other IT equipment
- Compatible with standard/edge/data center container data centers, supporting high/medium/low-density equipment layout
- Integrated deployment of industrial control, security monitoring and communication base station outdoor equipment
7.3 Power Supply & Distribution System Application Scope
- Power guarantee for all equipment inside container data centers including IT devices, cooling, fire protection and monitoring systems
- Independent power supply systems for regions with unstable municipal power, remote areas and emergency scenarios
- Redundant power supply and long-duration backup for data centers and edge nodes
7.4 Cooling System Application Scope
- Heat dissipation for internal IT equipment in container data centers, maintaining stable temperature & humidity for normal equipment operation
- Adaptation to heat dissipation demands under harsh outdoor environments including high temperature, high humidity and sandstorms
- High-efficiency heat dissipation for high-density computing and AI computing clusters
7.5 Fire Protection & Security System Application Scope
- Fire prevention, detection and suppression for container data centers to protect equipment and data security
- Security monitoring and access control for outdoor/remote sites to prevent illegal intrusion and equipment theft
- Military-grade security and ultra-early fire warning for core data centers
7.6 Monitoring System Application Scope
- Real-time monitoring and remote management of container data center environment (temp/humidity/water immersion/smoke), equipment status and energy consumption
- Remote operation & maintenance, abnormality early warning and fault disposal for unattended machine rooms and outdoor sites
- Centralized unified management for multi-container clusters
8. Product Advantages
8.1 Core Functional Features of Series Products
(1) Container Enclosure
- Rapid Deployment: Factory prefabrication and pre-commissioning; only foundation construction, power & fiber connection required on-site, online within 24–48 hours, 3 times faster than traditional machine rooms
- Flexible Capacity Expansion: Single container independent operation, multi-container cluster stacking, capacity increased on demand without large-scale civil engineering
- Military-Grade Protection: IP55 protection, Grade 8–9 seismic resistance, waterproof, dustproof, moisture-proof, anti-corrosion and flame-retardant, adaptable to extreme environments
- High Energy Efficiency: Premium insulation layer + FreeCooling technology, PUE as low as 1.25, drastically cutting operating energy consumption
- Mobile Convenience: Standard ISO size, hoistable, transportable and relocatable for temporary/mobile scenarios
(2) IT Cabinet
- High-Density Load Bearing: Load capacity 800–1500kg with high-strength frame for stacked high-density equipment
- Isolated Cold/Hot Aisle Cooling: Separated cold & hot air channels with high ventilation efficiency, reducing cooling energy consumption and stabilizing equipment operation
- Modular Design: Complete accessories with flexible combination compatible with various equipment sizes and layouts
(3) Power Supply & Distribution System
- Stable & Reliable: Online UPS with N+1/2N redundancy and sufficient backup duration, seamless power switching for 7×24-hour power supply
- Intelligent Management: Precision power distribution cabinets + intelligent PDUs support remote voltage/current/energy consumption monitoring and remote switching for easy maintenance
- Safety Protection: Multi-stage lightning protection, overload, short-circuit and overtemperature protection to avoid equipment damage from electrical faults
(4) Cooling System
- High-Efficiency Heat Dissipation: Dual air/liquid cooling modes with FreeCooling energy-saving modules, PUE as low as 1.25 to meet high-density cooling demands
- Precise Temperature & Humidity Control: Minor fluctuations to stabilize operating environment for IT equipment
- Redundant Guarantee: N+1/N+2 redundant design; single unit failure will not disrupt overall heat dissipation for high reliability
(5) Fire Protection & Security System
- Ultra-Early Warning: Aspiration/combined detectors deliver ultra-early fire detection to minimize losses
- High-Speed Fire Suppression: FM200/aerosol suppression with auto activation, fast fire extinguishing, residue-free and eco-friendly
- Intelligent Security: Multi-mode access control (face/RFID/password/fingerprint) linked with video surveillance and intrusion detection for military-grade security
(6) Monitoring System
- Full-Dimension Monitoring: Zero-blind monitoring of temperature/humidity/water immersion/smoke/access control/energy consumption and equipment status
- Remote Operation & Maintenance: Real-time Web/APP remote monitoring, data storage & traceability, AI abnormality early warning for convenient unattended management
- Protocol Compatibility: Modbus/SNMP support for BMS integration and linked control of other equipment
8.2 Customization Advantages
- Size Customization: Standard 20/40ft specifications, non-standard sizes such as 10ft, 19㎡, 23㎡ and 29㎡ customizable
- Configuration Customization: Three base tiers (low/medium/high), personalized customization based on power density, redundancy level and protection requirements
- Function Customization: Special functions including liquid cooling, AI monitoring, explosion-proof design, enhanced anti-corrosion and noise reduction customizable
- Appearance Customization: Personalized design of color, logo, door opening direction and vent position
8.3 OEM & Confidential Production Advantages
- OEM/ODM Service: Support OEM/ODM manufacturing, production per customer brand and technical requirements with full technical support
- Confidential Production: Sign non-disclosure agreements to strictly protect customer technical solutions, parameters and drawings against information leakage
- Flexible Production: Flexible scheduling for both small-batch customization and mass production with short lead times
8.4 Spot Delivery Advantages
- Standard Inventory: Spot stock of standard prefabricated and edge computing 20ft models for immediate delivery upon order placement
- Fast Customized Production: 12–14 weeks production cycle for customized products, 20% faster than industry average
- Global Delivery: Standard ISO size compatible with sea, land and air transportation, global delivery with on-site installation & commissioning
8.5 Technical Parameter Advantages
- Industry-Leading Indicators: PUE as low as 1.25, Grade 9 seismic resistance, IP55 protection grade, 25-year service life; core parameters superior to industry standards
- Strong Compatibility: Compatible with 19-inch standard equipment and mainstream servers, storage and network devices of all brands
- Extreme Environment Adaptability: Stable operation under -40℃~+55℃ with high humidity, sandstorm and salt fog resistance
9. Bid Winning Technical Parameters (★ Marked Core Clauses)
9.1 Container Enclosure Bid Winning Parameters
★1. Size Specifications: Provide standard 20ft (6100×2438×2591mm) and 40ft (12192×2438×2591mm) models, non-standard sizes customizable ★2. Material: Corten A weathering steel with thickness ≥4mm, service life ≥25 years ★3. Protection Grade: IP55, waterproof, dustproof, moisture-proof, operable under -40℃~+55℃ extreme ambient temperatures ★4. Seismic Grade: ≥Grade 8 seismic resistance, floor load ≥1000kg/㎡, stackable, hoistable and transportable ★5. Thermal Insulation: 50mm thick PIR fire-resistant insulation layer, thermal conductivity ≤0.022W/(m·K)
9.2 IT Cabinet Bid Winning Parameters
★1. Specifications: 42U, dimensions ≥600×1000×2000mm, 19-inch standard mounting rails ★2. Load Capacity: ≥1000kg, high-strength cold-rolled steel frame with thickness ≥1.5mm ★3. Heat Dissipation: Cold/hot aisle isolation design, ventilation efficiency ≥85%
9.3 Online UPS Bid Winning Parameters
★1. Rated Capacity: Edge model ≥20kVA, data center model ≥60kVA ★2. Redundancy Level: N+1 redundancy for edge models, 2N redundancy for data center models ★3. Backup Duration: ≥30 minutes, efficiency ≥93%
9.4 Precision Air Conditioner Bid Winning Parameters
★1. Cooling Capacity: Edge model ≥10kW, data center model ≥20kW ★2. Cooling Mode: Equipped with FreeCooling energy-saving technology; data center models support liquid cooling ★3. PUE Value: ≤1.25, redundancy level N+1 or higher ★4. Temperature & Humidity Control: Temp 22±2℃, RH 40%–60%
9.5 Fire Protection System Bid Winning Parameters
★1. Detection Mode: Data center models adopt ultra-early smoke aspiration detectors ★2. Fire Suppression Medium: FM200 clean gas with dual auto/manual activation modes
9.6 Monitoring System Bid Winning Parameters
★1. Monitoring Dimensions: Full monitoring of temperature/humidity/water immersion/smoke/access control/energy consumption ★2. Remote Management: Web/APP remote monitoring support, data storage ≥1 year ★3. Protocol Compatibility: Modbus/SNMP support for BMS integration
10. Full Product Solutions
10.1 Standard Prefabricated Container Data Center Solution
- Applicable Scenarios: Small & medium enterprises, branch offices, remote sites, temporary offices; limited budget and basic IT demands
- Core Configuration: 20ft enclosure + 2 sets of 42U cabinets + 10kVA UPS + 6kW air conditioner + basic fire protection & security
- Solution Advantages: Low cost, rapid deployment, standardized design, easy maintenance to meet basic IT equipment storage & operation demands
- Implementation Process: On-site foundation construction (1 day) → container hoisting & positioning (1 day) → power & fiber connection (1 day) → commissioning & online launch (1 day); total delivery within 4 days
10.2 Edge Computing Container Data Center Solution
- Applicable Scenarios: 5G edge nodes, IoT, industrial internet, smart transportation, outdoor monitoring; low-latency local data processing demands
- Core Configuration: Reinforced 20ft enclosure + 3 sets of 42U cabinets + 2 sets of 20kVA N+1 UPS + 10kW FreeCooling air conditioners + intelligent monitoring & security
- Solution Advantages: Miniaturized, low power consumption, online deployment within 48 hours, adaptable to harsh outdoor environments, compatible with 5G for low-latency data processing
- Implementation Process: Simple on-site foundation (0.5 day) → container positioning (0.5 day) → power & fiber access (1 day) → linkage commissioning (1 day); total delivery within 3 days
10.3 Data Center Container Data Center Solution
- Applicable Scenarios: Internet data centers, cloud computing nodes, core finance & government machine rooms, disaster recovery centers; high density, high reliability and 7×24-hour operation demands
- Core Configuration: Military-grade 40ft enclosure + 8 sets of 42U cabinets + 4 sets of 60kVA 2N UPS + 20kW liquid-cooled air conditioners + ultra-early fire protection + AI intelligent monitoring
- Solution Advantages: Redundant architecture, liquid cooling, PUE as low as 1.25, military-grade protection, AI early warning, multi-container cluster support for high-density computing deployment with superior reliability
- Implementation Process: Professional on-site foundation (2 days) → cluster container positioning (1 day) → power & cooling system installation (2 days) → fire protection & monitoring commissioning (1 day) → overall joint debugging (1 day); total delivery within 7 days
10.4 Multi-Container Cluster Capacity Expansion Solution
- Applicable Scenarios: Data center expansion, large cloud computing platforms, AI computing clusters; on-demand capacity expansion demands
- Core Configuration: Multiple 40ft data center containers stacked in clusters, interconnected with unified power supply, cooling and monitoring systems
- Solution Advantages: Modular expansion without large-scale civil engineering, fast IT capacity increase, unified management and resource sharing to lower TCO
- Implementation Process: Cluster layout planning → on-site foundation construction → container positioning → system interconnection → unified commissioning → online operation; expansion cycle 50% shorter than traditional machine rooms
10.5 Harsh Outdoor Environment Solution
- Applicable Scenarios: Oilfields, mines, deserts, coastal salt fog areas, high temperature & high humidity regions; IT deployment under extreme environments
- Core Configuration: IP55 reinforced enclosure + anti-corrosion treatment + seismic reinforcement + wide-temperature UPS + high-temperature dedicated air conditioners + moisture-proof security monitoring
- Solution Advantages: Military-grade protection, stable operation under -40℃~+55℃ extreme environments, anti-corrosion, moisture-proof, dustproof and seismic resistance with low maintenance costs
11. Product Application Cases
11.1 Standard Prefabricated Container Data Center for a State-Owned Enterprise Branch
- Project Overview (2025): Deployed a 20ft standard prefabricated container data center for a remote branch of a state-owned enterprise to solve the lack of indoor machine rooms and decentralized IT equipment management issues
- Configuration List: KITOZER-20S enclosure + 2 sets of R42S cabinets + 1×10kVA UPS + 1×6kW air conditioner + basic fire protection & security
- Project Outcomes: Full deployment completed within 4 days; centralized IT equipment management with stable operation and easy maintenance. Construction cost reduced by 60% and construction cycle shortened by 80% compared with traditional machine rooms
11.2 5G Edge Computing Container Data Center for a Telecom Operator
- Project Overview (2025): Deployed a 20ft edge computing container data center matched with the operator’s 5G base stations to carry edge computing and IoT data processing services
- Configuration List: KITOZER-20E enclosure + 3 sets of R42E cabinets + 2×20kVA UPS + 2×10kW air conditioners + intelligent monitoring & security
- Project Outcomes: Full deployment completed within 3 days, adaptable to high temperature & high humidity outdoor environments with PUE ≤1.3, supporting low-latency data processing and stable operation without faults to meet 5G edge service demands
11.3 Data Center Container Data Center for an Internet Company
- Project Overview (2025): Deployed a 40ft data center container data center as a cloud computing node to carry high-density server services
- Configuration List: KITOZER-40D enclosure + 8 sets of R42D cabinets + 4×60kVA UPS + 4×20kW liquid-cooled air conditioners + ultra-early fire protection + AI monitoring
- Project Outcomes: Full deployment completed within 7 days, PUE as low as 1.25 with 2N redundant architecture supporting 7×24-hour uninterrupted high-density computing operation, cutting operating energy consumption by 40% versus traditional data centers
11.4 Harsh Environment Container Data Center for a Mine
- Project Overview (2025): Deployed a reinforced 20ft container data center for a mine to carry mine monitoring, industrial control and data storage services under high temperature, sandstorm and vibration conditions
- Configuration List: Reinforced KITOZER-20E enclosure + anti-corrosion treatment + 3 sets of R42E cabinets + 2×20kVA UPS + 2×10kW high-temperature air conditioners
- Project Outcomes: Adaptable to mine extreme environments with Grade 8 seismic resistance and IP55 protection, stable operation for 1 full year without faults, solving issues of unavailable proper machine rooms and vulnerable equipment damage in mines
11.5 Disaster Recovery Container Data Center for a Government Agency
- Project Overview (2025): Deployed two 40ft data center container data centers as an off-site disaster recovery center to carry government data backup and emergency business recovery
- Configuration List: 2×KITOZER-40D enclosures + 16 sets of R42D cabinets + 8×60kVA UPS + 8×20kW liquid-cooled air conditioners + cluster monitoring
- Project Outcomes: Multi-container cluster deployment with unified management, real-time data backup and rapid business recovery during emergencies to guarantee government data security with superior reliability
12. Product Faults & Maintenance
12.1 Common Faults & Troubleshooting Methods
(1) Enclosure Structural Faults
- Fault Phenomena: Enclosure water leakage, insulation layer peeling, door deformation
- Troubleshooting: Check aging/damage of sealing strips; check fixation of insulation layer; check looseness/deformation of door hinges
- Solutions: Replace aging sealing strips; re-fix insulation layers; adjust door hinges and correct deformation
(2) UPS Faults
- Fault Phenomena: Failure to power on, frequent bypass switching, short battery backup duration, alarm triggers
- Troubleshooting: Check normal municipal power input; check battery connection tightness & aging; check overload load; check cooling ventilation
- Solutions: Repair municipal power lines; replace aged batteries; reduce equipment load; clean cooling fan dust
(3) Precision Air Conditioner Faults
- Fault Phenomena: No cooling, poor cooling effect, abnormal temperature/humidity, alarm triggers
- Troubleshooting: Check power supply; check refrigerant leakage; check blocked filters; check outdoor unit heat dissipation; check faulty sensors
- Solutions: Repair power supply; replenish refrigerant; clean filters; remove dust from outdoor units; replace defective sensors
(4) Fire Protection System Faults
- Fault Phenomena: False/missed alarms from detectors, failure to activate fire suppression units
- Troubleshooting: Check dirty/aged detectors; check loose/short-circuited wiring; check fire suppression unit pressure; check activation control circuits
- Solutions: Clean or replace detectors; repair wiring; replenish fire suppression medium; troubleshoot control circuit faults
(5) Monitoring System Faults
- Fault Phenomena: Failed remote access, data loss, no signal from sensors, no camera video
- Troubleshooting: Check network connection; check full monitoring host storage; check loose sensor wiring; check camera power supply
- Solutions: Repair network links; clear storage data; re-connect wiring; repair camera power supply
12.2 Daily Maintenance Schedule
(1) Daily Inspection
- Visual enclosure inspection: Check for damage, deformation, water leakage and intact door sealing
- Equipment operating status inspection: Check normal indicator lights of UPS, air conditioners and monitoring hosts for alarms
- Temperature & humidity inspection: Maintain internal temp at 22±2℃ and RH 40%–60%, adjust promptly for abnormalities
- Security inspection: Normal operation of access control and cameras, no abnormal intrusion alarms
(2) Weekly Maintenance
- Air conditioner filter cleaning: Remove, rinse and reinstall filters to guarantee heat dissipation efficiency
- UPS battery inspection: Check battery voltage, internal resistance, bulging and liquid leakage
- Circuit connection inspection: Check tightness of power/data cables for looseness and aging
- Fire detector test: Simulate smoke to verify normal alarm response of detectors
(3) Monthly Maintenance
- Internal enclosure cleaning: Remove dust and debris to avoid heat dissipation obstruction
- Earthing system inspection: Verify earthing resistance ≤4Ω with no corrosion or looseness on earthing strips
- UPS switching test: Simulate municipal power outage to test seamless UPS switching and qualified battery backup duration
- Sensor calibration: Calibrate temperature/humidity and water immersion sensors to ensure accurate monitoring data
(4) Annual Full Maintenance
- Complete enclosure inspection: Full check of anti-corrosion coating, insulation layer and sealing strips; replace aged damaged components
- In-depth UPS maintenance: Battery charge-discharge cycle test, mass replacement of aged batteries, internal dust removal
- In-depth air conditioner maintenance: Refrigerant pressure testing, pipeline leakage inspection, deep outdoor unit cleaning and compressor status check
- Full fire protection system test: Fire suppression unit pressure inspection, activation test and pipeline inspection to ensure availability
- Full monitoring system calibration: Calibrate all sensors and cameras, back up storage data and upgrade system firmware
12.3 Maintenance Precautions
- Cut power supply of related equipment before maintenance, hang warning signs to prevent electric shock and equipment damage
- Wear safety harnesses for high-altitude maintenance (e.g., enclosure rooftop) with full protective measures
- Reset fire protection systems after maintenance to avoid false alarms
- Record all maintenance work and build maintenance archives for traceability
- Forbid non-professional personnel to disassemble or repair equipment to avoid fault escalation
13. Factory Strength & After-Sales Service
13.1 Factory Strength
- Production Scale: KITOZER owns a professional container data center manufacturing base covering 10,000㎡, with annual output of over 500 container data centers and 10,000 IT cabinets to meet mass and customized production demands
- Technical Team: R&D, design and production team of over 50 staff with more than 10 years of modular data center R&D experience, independent core technology and multiple patents
- Production Equipment: Introduced laser cutting machines, CNC bending machines, automatic spraying lines, enclosure air tightness testing equipment and full-load 72-hour aging test equipment for fully automated high-precision stable production
- Quality Control: Strictly implement ISO9001 quality system certification, including incoming raw material inspection, in-process patrol inspection and full finished product inspection, with 72-hour full-load aging testing to guarantee product compliance
- R&D Innovation: Continuous R&D investment to upgrade liquid cooling, AI monitoring and energy-saving technologies, maintaining industry-leading product performance
13.2 After-Sales Service System
(1) Warranty Commitment
- Container Enclosure: 5-year warranty, lifetime structural maintenance
- IT Cabinets: 3-year warranty, lifetime maintenance
- UPS, Air Conditioners, Fire Protection & Monitoring Equipment: 3-year warranty, core components extendable to 5-year warranty
- Free repair and component replacement for non-artificial damage within warranty period, free on-site service
(2) Service Process
- Pre-Sales Service: Free on-site survey, solution design, configuration optimization and technical consultation to deliver professional customized solutions
- In-Sales Service: Factory prefabrication and pre-commissioning with full-process quality control; professional team for on-site installation, commissioning and training to ensure smooth project delivery
- After-Sales Service: 7×24-hour technical support hotline, 1-hour response, solution provided within 4 hours, 24-hour on-site service (domestic); regular follow-up inspections, maintenance and lifetime technical support
(3) Service Advantages
- National Service Network: Over 20 service outlets covering all provinces and cities nationwide for nearby fast response service
- Professional Technical Team: After-sales engineers with over 5 years of industry experience and professional training for efficient fault resolution
- Remote Operation & Maintenance Support: Remote monitoring, remote troubleshooting and remote upgrade services to resolve most faults without on-site visits
- Spare Parts Guarantee: National spare parts warehouses with sufficient inventory of common components for fast replacement to minimize equipment downtime
14. Conclusion
As a core product of modular data centers, KITOZER container data centers solve pain points of traditional machine rooms including long construction cycles, high costs, poor flexibility and weak environmental adaptability, with core strengths of rapid deployment, flexible capacity expansion, high energy efficiency, reliable safety and strong customization.
Covering three configuration tiers (low/medium/high), the product line delivers industry-leading core parameters, and supports OEM/ODM, confidential production and spot delivery. Widely applied in enterprises, telecom operators, internet, finance, government, mining and oilfield industries, it has delivered multiple benchmark projects and received consistent customer recognition.
Moving forward, KITOZER will continue to deepen its layout in the modular data center sector, increase R&D investment, continuously optimize product performance and upgrade service quality. We will provide customers with more efficient, reliable and energy-saving container data center solutions to accelerate construction and upgrading of digital infrastructure.
15. SEO Optimization System
15.1 Core Keywords
- Primary Core Keywords: Container Data Center, Prefabricated Container Data Center, Data Center Container, Edge Computing Container Data Center, KITOZER Container Data Center
- High-Conversion Long-Tail Keywords: 20ft Container Data Center, 40ft Container Data Center, Outdoor Container Data Center, Modular Container Data Center, Container Data Center Solution, Container Data Center Configuration List
- Industry Traffic Keywords: Modular Data Center, Prefabricated Data Center, Edge Computing Data Center, Containerized Data Center, Outdoor Machine Room, Mobile Data Center
- Brand Exclusive Keywords: KITOZER, KITOZER Cabinet, KITOZER UPS, KITOZER Precision Air Conditioner, KITOZER Monitoring System
- Dropdown & Related Search Keywords: Container Data Center Price, Container Data Center Manufacturer, Container Data Center Construction Plan, Container Data Center PUE, Container Data Center Maintenance
15.2 SEO Optimization Tag System
(1) Core Page Optimization Tags
- Page Title: KITOZER Container Data Center Solution – Prefabricated / Data Center / Edge Computing Container Data Center
- Subtitle: Modular Prefabricated Container Data Center Manufacturer, Rapid Deployment & High Energy Efficiency, Customization & OEM Available
- Page Keywords: Container Data Center, Prefabricated Container Data Center, Data Center Container, Edge Computing Container Data Center, KITOZER
- Page Description: KITOZER provides three series of container data center solutions including standard prefabricated, data center and edge computing types. Factory prefabricated and pre-commissioned, rapid deployment, military-grade protection, supporting customization, OEM/ODM and confidential production with spot delivery. Suitable for enterprises, telecom operators, internet, finance, government and mining industries with one-stop solutions and comprehensive after-sales service.
(2) Title Tags
- Homepage Title: KITOZER Container Data Center – Prefabricated / Data Center / Edge Computing Container Data Center Manufacturer
- Solution Page Title: Container Data Center Solution – Standard Prefabricated / Data Center / Edge Computing Series – KITOZER
- Product Page Title: KITOZER Container Data Center – 20/40ft Modular Prefabricated Machine Room
(3) Meta Keywords
Meta Keywords: Container Data Center, Prefabricated Container Data Center, Data Center Container, Edge Computing Container Data Center, Modular Data Center, Outdoor Machine Room, Mobile Data Center, KITOZER
(4) Meta Description
Meta Description: KITOZER container data center is a professional modular prefabricated data center with three product lines: standard prefabricated, data center and edge computing. Standard 20/40ft sizes, factory prefabrication & pre-commissioning, rapid deployment, high energy efficiency and military-grade protection. Customization, OEM/ODM and confidential production available with spot delivery. Widely applied in enterprises, telecom operators, internet, finance, government and mining industries, offering one-stop solutions and complete after-sales service.
(5) H1 Tag
H1: KITOZER Container Data Center Solution
(6) H2 Tags
H2: System Overview, System Composition, System Classification, System Schematic Diagrams, Full System Configuration List, Product Technical Specifications, Product Application Scope, Product Advantages, Bid Winning Technical Parameters, Product Solutions, Application Cases, Product Faults & Maintenance, Factory Strength & After-Sales Service, Conclusion
(7) Internal Link Optimization Tags
- Core Anchor Texts: Container Data Center, KITOZER Container Data Center, Container Data Center Solution
- Long-Tail Anchor Texts: Prefabricated Container Data Center, Data Center Container, Edge Computing Container Data Center, 20ft Container Data Center, 40ft Container Data Center, Outdoor Container Data Center
- Related Anchor Texts: Modular Data Center, Prefabricated Data Center, Edge Computing Data Center, KITOZER Cabinet, KITOZER UPS, KITOZER Precision Air Conditioner
这篇文章的语言风格可以更正式一些吗?
你可以润色一下这篇文章吗?
你能帮我翻译一下其他类型的文章吗?
快速
图像生成
帮我写作
翻译
PPT 生成
视频生成
深入研究
AI 播客
更多