The KITOZER automatic cooling water dosing unit maintains water quality in open cooling tower loops and closed chilled water systems. It injects corrosion inhibitor, scale inhibitor, and biocide on schedule or based on conductivity signal, preventing tube fouling, scale buildup, and microbiological growth. Proper chemical treatment extends chiller tube life by 10 years or more and maintains heat transfer efficiency at design level.
Without chemical treatment, cooling tower water concentrates minerals as evaporation removes pure water. Scaling forms on condenser tubes as calcium carbonate precipitates, adding 1 mm of scale can reduce heat transfer by 10 percent. Biological slime and Legionella biofilm further reduce efficiency and pose health risks. The dosing unit prevents these issues by maintaining inhibitor residual and controlling cycles of concentration through automatic blow down.
Table of Contents
ToggleProduct Overview
KITOZER dosing skids include one or two chemical dosing pumps, a 100 L or 200 L PE chemical tank, low level float switch, strainer, injection valve, and a microcontroller with conductivity and make up water pulse inputs. The controller can run on timer based dosing, conductivity based blow down, or biocide shock dosing cycles. The skid is mounted on a powder coated steel frame for wall or floor installation. All wetted parts are chemically resistant PP or PVDF.
The dosing pump is a solenoid driven diaphragm type with adjustable stroke length and frequency. The pump automatically primes and degasses on each stroke. A pressure relief valve protects the chemical line from overpressure. The PE tank has a wide opening for easy filling, a screw cap with vent, and a low level alarm switch. Optional second pump provides dual chemical dosing such as scale inhibitor and biocide on independent schedules.
Technical Specifications
Dosing pump flow 0 to 2 L per h adjustable, max pressure 6 bar. Tank capacity 100 L PE. Conductivity sensor range 0 to 2000 microS per cm. Power supply 220 V 50 Hz, power 60 W. Control signal 4 to 20 mA and RS485 Modbus. Protection class IP55. Weight 35 kg. Dimensions 600 x 400 x 900 mm. CE certified, 2 year warranty.
Application Scenarios
This unit is installed on cooling tower make up lines for commercial HVAC, power plant condenser loops, and industrial process cooling. It is also used on closed chilled water loops to maintain corrosion inhibitor concentration. Pairing with a side stream sand filter or automatic screen filter provides comprehensive water treatment. The unit is a standard accessory on all KITOZER chiller plant packages.
In hospitals and food plants, biocide dosing controls Legionella and biofilm to meet health codes. In hotels, the unit maintains tower water quality without manual chemical handling. In manufacturing, it protects expensive process heat exchangers from scaling. The controller logs all dosing events and blow down cycles for compliance reporting.
Advantages and Features
Automatic dosing eliminates manual chemical handling and dosing errors. Conductivity controlled blow down saves water by only draining when cycles of concentration exceed the setpoint. Low level tank alarm prevents pump running dry. Two pump configurations allow dual chemical dosing such as scale inhibitor and biocide on separate schedules. The compact skid arrives pre assembled, reducing site installation labor. BMS integration allows remote monitoring of chemical residual and tank level.
Compared with manual dosing by maintenance staff, automatic dosing maintains consistent chemical residual 24 hours per day. The solenoid pump dose is accurate to plus or minus 2 percent. The controller can be programmed for weekly biocide shock cycles that kill biofilm without manual intervention. Chemical consumption is logged, allowing budget forecasting.
Installation and Maintenance
Mount the skid near the cooling tower basin or make up water line. Install a back pressure valve on the injection line. Calibrate conductivity sensor before commissioning. Set dosing rate based on make up water volume and chemical vendor recommendations.
Monthly tasks include checking chemical tank level, inspecting injection valve for clogging, and calibrating conductivity probe. Annually replace dosing pump diaphragm and valves, and flush the chemical tank. Keep a log of chemical usage and conductivity readings. Refill chemical tanks before they run empty to avoid damaging the pump.
Price
From $1,180 per skid. Contact KITOZER for multi pump system pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com