KITOZER Cooling Water Pump 200m3/h For Condenser Loop

The KITOZER 200 m3 per hour cooling water pump is engineered for condenser water loops that circulate water between chillers and cooling towers. Designed for continuous duty in open loop systems, the pump features a heavy duty mechanical seal, corrosion resistant wet end, and oversized bearings to handle the higher temperature and suspended particle conditions typical of condenser water. It is commonly paired with KITOZER 300RT to 500RT chillers and cross flow cooling towers to form a complete condenser water package.

Product Overview

KITOZER cooling water pumps are horizontal end suction centrifugal units with a back pull out design. The casing is epoxy painted cast iron for protection against cooling tower water chemistry. The impeller is wear resistant bronze or duplex stainless steel. A double mechanical seal with flush water connection is standard to protect seal faces from debris in open loop water. The motor is IP55, F class insulation, suitable for plant room and outdoor installation when covered. An optional baseplate assembled twin pump skid with common suction and discharge headers simplifies site installation.

Technical Specifications

Rated flow 200 m3 per h, rated head 28 m. Speed 1480 rpm. Motor power 22 kW, IE3, 3 phase 380 V 50 Hz. NPSH required 5 m. Inlet DN150, outlet DN125, PN16. Maximum pressure 16 bar. Maximum liquid temperature 80 C. Mechanical seal double acting with flush. Weight 480 kg. Casing material HT250 epoxy coated, impeller bronze, shaft 42CrMo with stainless sleeve. CE certified, 2 year warranty.

Application Scenarios

Typical duty includes condenser water circulation for centrifugal or screw chillers in commercial central plants, heat pump water source loops, and industrial cooling tower loops for compressor stations, hydraulic oil coolers, and injection molding machines. The pump can be used in duty standby or duty assist duty configurations. With a VFD tied to cooling tower approach temperature, the pump speed modulates to maintain constant condenser water temperature, reducing tower fan and pump energy simultaneously. It is also suitable for geothermal heat pump open loop systems when filtered water is supplied.

Advantages and Features

Double mechanical seal prevents cooling tower debris from entering the bearing chamber, extending seal life by 2 to 3 times compared with single seal designs. The back pull out design allows seal and bearing service without disconnecting piping. Heavy duty bearings have L10 life exceeding 50,000 hours. The hydraulically balanced impeller reduces axial thrust and shaft deflection. Epoxy coating on wetted internal surfaces inhibits rust and scale accumulation. The baseplate is supplied with drilled spring isolation mounting points for direct installation on concrete.

Installation and Maintenance

Install a Y strainer with at least 20 mesh on the suction side to prevent debris from entering the pump. Ensure the suction pipe slope is positive toward the pump to avoid air pockets. Always prime before startup. Do not run the pump against a closed discharge valve for more than two minutes. Check seal flush flow during operation. Inspect the impeller and wear rings annually by back pulling the rotating assembly. Lubricate bearings every 6 months. Monitor pump vibration velocity; baseline should be below 2.8 mm per second, and alarm at 4.5 mm per second. Replace wear rings when clearance exceeds 1.5 times new clearance.

Price

From $2,450 per pump. Contact KITOZER for twin pump skid and VFD control panel package.