KITOZER copper-clad steel grounding electrode rod 14.2mm diameter by 2.5m length is the driven vertical earth stake used in soil with medium to high resistivity. The rod combines a high-tensile steel core for driving strength with a 0.25mm molecular-bonded copper shell for corrosion resistance and conductivity. Unlike pure copper rods, the steel core survives repeated hammering without buckling, allowing installers to reach deep moisture layers and stable earth temperature. Unlike galvanized rods, the copper shell provides 10 times longer corrosion life in acidic soils. KITOZER supplies pointed tips, couplers, and driving heads to extend rods to 15m or more in difficult ground. The molecular bond ensures the copper shell remains intact even when the rod is driven through gravel or soft rock.
Technical Specifications
Core material: low-carbon steel with tensile strength not less than 600 N/mm2. Shell: electrolytic copper molecular bonded, thickness 0.25mm minimum, total copper coverage not less than 99.9%. Diameter 14.2mm, length 2.5m per section. Couplers: brass or copper-threaded, NPT 3/4 inch. Driving head: hardened steel cap. Point: forged conical tip. DC resistance per 2.5m rod in average 100 ohm.m soil: about 30 ohm. Short-time current rating: 25 kA for 1 second. Expected life in pH 6 to pH 9 soil: not less than 40 years. Operating temperature: minus 40C to plus 80C. Certifications: IEC 62561-2, ISO 9001, RoHS. Brand: KITOZER. Warranty: 30 years against copper shell separation. The rod is compatible with exothermic weld molds for most common tape sizes.
Application Scenarios
This electrode rod is the standard vertical earth element for substations, transmission line towers, wind turbine foundations, solar farm racking, telecom base stations, building lightning protection down conductors, and industrial plant grids. It is driven vertically into soil below the frost line to reach stable moisture. In rocky ground, rods are joined with couplers and driven with a jackhammer to reach 6m, 9m, or 12m. Multiple rods are arranged in parallel rows or rings and interconnected with copper tape to meet design resistance targets. The rod is also used as the reference earth electrode for ground resistance testers and as the neutral point earthing for distribution transformers. In urban sites, rods are driven in narrow trenches between buildings where large grids are impractical.
Advantages and Features
The molecular bonding process creates a metallurgical bond between copper and steel, so the shell does not delaminate during driving or thermal cycling. The steel core provides enough strength to penetrate compacted soil and soft rock that would buckle pure copper. The 0.25mm copper thickness exceeds the 100 micron minimum required by IEC 62561-2, ensuring long corrosion life in acidic or saline soil. KITOZER rods are supplied with pre-attached pointed tips and threaded tops, eliminating field welding. Couplers are precision-machined for quick joining. Compared with chemical grounding electrodes, this rod is lower cost, easier to install, and does not require backfill mixing. The rod is also compatible with exothermic welding to the busbar. The copper shell provides stable conductivity over decades of soil contact.
Installation and Maintenance Recommendations
Drive the rod vertically using a hammer drill with a KITOZER driving head; do not strike the threaded end directly. Keep the rod plumb with a spirit level during driving. When joining sections, apply anti-seize compound to couplers and tighten with a wrench. Leave 100mm of rod exposed above ground for connection, or install an inspection pit. Connect to the grid with exothermic weld or bolted clamp, then coat the joint with bitumen. Backfill the pit with bentonite or grounding enhancement agent if soil resistivity exceeds design. Measure rod resistance with a fall-of-potential tester after installation and record the value. Re-test every three years; resistance drift above 20% indicates soil drying or joint corrosion. In extreme cold regions, drive rods below the frost depth. KITOZER provides driving tools, weld molds, and resistance test forms.
Quality Assurance and Ordering Information
Every KITOZER rod carries a laser-etched batch number and is supplied with a mill test report covering copper thickness, tensile strength, and resistance. Rods are packed in wooden crates of 50 pieces with plastic caps on threads. Standard lead time is 7 days. Custom diameters from 11.5mm to 25mm and lengths from 1.5m to 3m are available. KITOZER also supplies driving heads, couplers, exothermic weld powder, and weld molds as a complete package. For export, KITOZER provides fumigated wooden crates and certificate of origin. Samples can be shipped within 48 hours for driving trials. KITOZER also offers on-site installation supervision and post-installation resistance testing as a paid service. The rod is available in 14.2mm, 16mm, 17.2mm, and 20mm diameters for different fault current levels, and in lengths from 1.5m to 5m per section. Couplers are supplied pre-threaded and include a brass anti-seize plug.
Price
From $18 per rod including tip and driving head. Contact +86 13922289957 for project pricing and coupler accessories.